Schneider Electric I/O & Function Modules
Schneider Electric TM3DQ32UK
Discrete output module
Genuine surplus Schneider TM3DQ32UK: 32 NPN transistor outputs, 24 V DC, HE-10. Verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Discrete output type | Transistor |
|---|---|
| Discrete output number | 32 |
| Discrete output logic | Negative logic (sink) |
| Discrete output voltage | 24 V DC for transistor output |
| Discrete output current | 100 mA for transistor output |
| Electrical connection | HE-10 connector for outputs |
| Response time | 450 µs (turn-on), 450 µs (turn-off) |
| Mounting support | Top hat type TH35-15 or TH35-7.5 rail conforming to IEC 60715; plate or panel with fixing kit |
| Dimensions (H x D x W) | 90 mm x 81.3 mm x 33.5 mm |
| Net weight | 0.112 kg |
Description
When a Modicon M241 or M251 machine loses its output card, every hour of downtime eats into production and maintenance budgets. Sourcing a genuine Schneider Electric TM3DQ32UK discrete output module quickly and at a sensible price is the practical way to restore 32 transistor outputs without paying OEM list price or waiting weeks for new stock. Autronexa supplies verified surplus and refurbished units with clear lead times.
What This Output Module Does in a Modicon System
The TM3DQ32UK is a 32-channel transistor output module from the Modicon TM3 range, compatible with M221, M241, M251 and M262 controllers. Its outputs use negative logic (sink) at 24 V DC and deliver 100 mA per channel, so it suits solenoid valves, small relays, indicator lamps and other DC loads that need fast, repeatable switching. Each channel has a green status LED, which shortens fault-finding and keeps troubleshooting labour costs down. The module connects to the controller bus with low current draw — 5 mA at 5 V DC and 0 mA at 24 V DC when outputs are off — so it adds minimal load to the backplane supply. Response time is 450 µs turn-on and turn-off, keeping machine cycle times predictable. Wiring lands on a single HE-10 connector for outputs, which simplifies replacement and reduces rewiring time during a swap.

Surplus Advantage: Cost and Lead Time on a Proven Module
Buying this module as genuine surplus or refurbished changes the cost equation in two ways. First, the purchase price is typically below OEM list, which matters when a single machine needs several output cards or when a spare is held on the shelf. Second, availability is immediate rather than tied to a factory lead time, so a failed card does not stall a production line. Autronexa tests refurbished units against OEM datasheet specifications and functionally verifies them before dispatch. The module carries CE marking and cULus, UKCA, RCM and EAC certifications, and its insulation between output and internal logic is rated at 500 V AC — details worth confirming on the label when a unit arrives. For maintenance teams managing M221 through M262 platforms, surplus stock of this exact output card is a practical way to control spares spend without compromising on authenticity.

Selection and Sourcing Checks Before You Order
Before committing, confirm the exact model and output configuration: 32 transistor outputs, negative logic (sink), 24 V DC, HE-10 connection. Check that your application’s loads stay within the 100 mA per channel rating and that the maximum tungsten load of 1.2 W suits any lamp loads on the circuit. The module mounts on TH35-15 or TH35-7.5 DIN rail, or on a panel with a fixing kit, and measures 90 mm high, 81.3 mm deep and 33.5 mm wide at 0.112 kg. Operating temperature depends on mounting: -10…35 °C vertical and -10…55 °C horizontal. Unshielded cable runs between devices should stay under 5 m. When comparing surplus offers, ask for the condition grade and any test record. Autronexa provides verified condition details and can confirm current availability against your part number. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine Schneider Electric TM3DQ32UK, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference. The module carries CE marking and cULus, UKCA, RCM and EAC certifications as listed in the datasheet.
What condition will the TM3DQ32UK arrive in?
Units are supplied as refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask Autronexa for the specific condition grade on current stock.
How fast can you ship the TM3DQ32UK?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability before ordering.
Does this module work with Modicon M241 and M251 controllers?
Yes. The TM3DQ32UK is listed as compatible with Modicon M221, M241, M251 and M262 controllers, connecting via the HE-10 output connector.
Is the TM3DQ32UK still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability for this module.
Related & compatible parts
Schneider Electric
140AMM09000C
Genuine surplus Schneider Electric 140AMM09000C analog input module — 4 inputs, 21 Hz filter, verified and ready to…
Schneider Electric · Advantys STB
STBDDI3610
Genuine surplus Schneider Electric STBDDI3610 digital input module — 6 channels, 24V DC, hot-swappable, verified condition and ready…
Schneider Electric
140NOC77100C
Genuine surplus Schneider Electric 140NOC77100C TCP/IP module for Modicon Quantum — verified condition, practical lead times, sourcing help…
Schneider Electric
TSXDEY16D3
Genuine surplus Schneider Electric TSXDEY16D3 Modicon Premium 16-point DC input module — verified condition, sourcing help, faster than…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…