Schneider Electric I/O & Function Modules
Schneider Electric TSXDEY16D3
Input Module Modicon Premium 16-point DC 48V
Genuine surplus Schneider Electric TSXDEY16D3 Modicon Premium 16-point DC input module — verified condition, sourcing help, faster than OEM lead time.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Channels | 16 points (2 groups × 8) |
|---|---|
| Signal type | DC input, sink (negative logic) |
| Voltage range | 48 V DC |
| Input current | 7 mA (state 1 per channel) |
| Isolation | Channel-to-bus: 1500 V AC dielectric; isolation resistance >10 MΩ @ 500 V |
| Response time | 4 ms (typical) |
| Bus current | 80 mA @ 5 V DC |
| Power consumption | 1.0 W + (0.15 W × number of channels used) |
| Protection rating | IP20 |
| Dimensions (H×W×D) | 140 × 35 × 80 mm |
Description
The Schneider Electric TSXDEY16D3 is a Modicon Premium 16-point DC input module built for 48 V DC field signals, and it is now discontinued. Maintenance and procurement teams keeping Premium racks running need a genuine unit rather than a clone, and verified surplus stock is often the fastest route to a working channel bank. Autronexa supplies this module as genuine surplus, tested against OEM datasheet specifications and functionally verified before dispatch.
What This Input Module Does in a Premium Rack
The module presents 16 input points arranged as two groups of eight, accepting 48 V DC sink signals. Each channel draws 7 mA in state 1, so the field supply load stays predictable when you total the points in use. Response time is 4 ms typical, which suits discrete sensing and interlock feedback rather than high-speed counting. Channel-to-bus isolation is rated 1500 V AC dielectric with isolation resistance above 10 MΩ at 500 V, protecting the backplane from field-side faults. The module occupies one slot and measures 140 × 35 × 80 mm at 0.15 kg, so it fits standard Premium rack positions without re-planning the enclosure.

Cost and Efficiency Implications of the Specification
Power budgeting is where this module rewards planning. Backplane draw is 80 mA at 5 V DC, and internal consumption is 1.0 W plus 0.15 W for each channel used. A rack populated with several input modules therefore scales its heat load with the number of active points, which matters in sealed cabinets where cooling capacity is fixed. The 7 mA per-channel field current keeps 48 V supply sizing straightforward. Because diagnostics are not available on this variant, fault finding depends on external indication and routine inspection, so budget for periodic checks rather than relying on module-level status reporting. The IP20 rating confirms the module belongs inside a protected enclosure, not on the plant floor.

Why Genuine Surplus Fits a Discontinued Module
Schneider Electric lists this module as discontinued, last verified 2026-09. That changes the sourcing calculation: OEM new stock may be unavailable or quoted with long lead times, while refurbished and surplus units can close the gap. Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference, so what arrives is a genuine module, not a lookalike. For maintenance teams holding spares budgets, surplus and refurbished stock typically costs less than chasing remaining new inventory, and the practical lead time is shorter when a channel bank is down. Confirm the exact revision and condition grade with our sourcing team before ordering, and verify current lifecycle status and availability with Autronexa.
Frequently asked questions
Is this TSXDEY16D3 a genuine Schneider Electric module or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it ships. The module is supplied as genuine surplus, not a grey-market copy.
What condition will the module arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask us to confirm the condition grade on the specific unit reserved for you.
How fast can you ship a discontinued TSXDEY16D3?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; surplus units usually move faster than OEM backorders on discontinued items.
Does the module work with 48 V DC field signals?
Yes. The data specifies a 48 V DC voltage range with DC input sink signals across 16 points in two groups of eight, at 7 mA per channel in state 1.
Is the TSXDEY16D3 still supported by Schneider Electric?
The data lists it as discontinued, last verified 2026-09. Contact Autronexa to verify OEM support status and current availability before ordering.
Related & compatible parts
Schneider Electric
TSXCTY2A
Genuine surplus Schneider Electric TSXCTY2A counter module for TSX Micro PLCs — 2 channels, 40 kHz, verified condition…
Schneider Electric
170INT11001
Genuine surplus Schneider Electric 170INT11001 INTERBUS-S adapter for Modicon Momentum I/O — verified condition, ready to ship.
Schneider Electric
171CBU78090
Genuine surplus Schneider Electric 171CBU78090 processor for Modicon Momentum — verified condition, practical lead times, and sourcing support…
Schneider Electric
TSXPSY5500M
Genuine surplus Schneider Electric TSXPSY5500M power supply module for TSX Micro PLCs — verified condition, ready to ship.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…