Schneider Electric I/O & Function Modules

Schneider Electric TSXCTY2A

Counter modules

Manufacturer: Schneider Electric Part Number: TSXCTY2A

Genuine surplus Schneider Electric TSXCTY2A counter module for TSX Micro PLCs — 2 channels, 40 kHz, verified condition and ready to ship.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Product Line TSX Micro PLCs
Channels 2
Counting Frequency 40 kHz
Input Compatibility 2/3-wire proximity sensors (PNP/NPN), incremental encoder (10-30 V totem pole, 5 V DC RS422)
Input Voltage 24 V (18 mA for sensors, 7 mA for auxiliary input, 18 mA for encoder)
Output Voltage 24 V DC
Nominal Output Current 0.5 A
Cycle Time 5 ms
Operating Temperature 0…60 °C
Electrical Connection 1 connector HE-10, 20 pins; 2 connectors SUB-D 15

Description

The Schneider Electric TSXCTY2A is a 2-channel counter module for TSX Micro PLCs, handling counting frequencies up to 40 kHz. Maintenance and automation teams choose genuine surplus or refurbished units to replace failed modules quickly, avoid OEM lead times, and keep legacy control systems running without paying full list price.

What the TSXCTY2A Does in Your Control System

This unit is an auxiliary output module that conforms to EN/IEC 61131. It provides two channels for counting and position feedback, with a cycle time of 5 ms and a response time under 2.5 ms when the 24 V auxiliary input is lost. That speed matters in applications where preset, enable, and read signals must react without delay. The module accepts 2/3-wire proximity sensors (PNP/NPN) and incremental encoders, including 10–30 V totem-pole and 5 V DC RS422 types. It also supplies a 24 V DC output to control connected devices, with a nominal output current of 0.5 A. Front-panel LEDs for RUN, I/O fault, ERR, and channel diagnostics help you confirm module status during commissioning and troubleshooting.

Figure 1: Front view of the Schneider Electric TSXCTY2A Counter modules showing its physical design and enclosure.

Why Genuine Surplus Makes Sense for This Module

Legacy TSX Micro PLCs remain common in packaging, material handling, and machine-tool cells, but sourcing exact-match counter modules through OEM channels can be slow and costly. Autronexa stocks genuine surplus and refurbished unit units that are tested against OEM datasheet specifications and functionally verified by our sourcing team. You get a verified part with clear lead times rather than an open-ended factory order. Because the module is part of the Modicon Premium Automation platform ecosystem, matching the exact part number and revision is critical — our team helps you confirm compatibility before shipment. For maintenance managers, this means less time waiting on procurement and more confidence that the replacement will drop into the existing rack and wiring.

Figure 2: Technical layout and connection details for the Schneider Electric TSXCTY2A Counter modules.

Buyer’s Checklist Before You Order

Start by confirming your PLC family and slot requirements: this module is designed for TSX Micro PLCs and uses one HE-10 20-pin connector plus two SUB-D 15 connectors. Verify your sensor or encoder type — PNP/NPN proximity sensors and 10–30 V totem-pole or 5 V DC RS422 encoders are supported. Check the operating environment: 0…60 °C ambient, 5…95 % relative humidity without condensation, and altitude up to 2000 m. Decide whether you need a surplus unit or a refurbished unit, and ask for the condition grade in writing. Finally, confirm the exact part number and any revision notes with your supplier. Contact Autronexa with your part number for verified condition and current availability.

Frequently asked questions

Is this a genuine Schneider Electric TSXCTY2A, or a clone?

Every TSXCTY2A we supply is verified against OEM datasheet markings and part-number cross-reference. We do not sell grey-market clones. Ask for our verification notes with your quote.

What condition will the TSXCTY2A arrive in?

Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — request the specific condition grade when you inquire.

How fast can you ship the TSXCTY2A?

Lead time depends on current stock. Contact Autronexa with your part number and we will confirm current availability and the expected ship date before you order.

Does the TSXCTY2A work with my existing sensors and encoders?

The module supports 2/3-wire proximity sensors (PNP/NPN) and incremental encoders with 10–30 V totem-pole or 5 V DC RS422 output. Confirm your sensor type and voltage against the datasheet before ordering.

Is the TSXCTY2A still supported by Schneider Electric?

Lifecycle status can vary by region and date. Contact Autronexa to verify OEM support status and availability for your specific application.

Related & compatible parts

Schneider Electric

BMXFTB4000

Genuine surplus Schneider Electric BMXFTB4000 40-pin cage clamp terminal block for Modicon X80 — verified condition, ready to…

In Stock

Schneider Electric

490NAC0100

Genuine surplus Schneider 490NAC0100 hot standby copper adapter for Modicon M580 redundant processors — verified condition, ready to…

In Stock

Schneider Electric

170MCI02110

Genuine surplus Schneider 170MCI02110 Modicon Momentum I/O cable — verified, tested, and ready to ship from Autronexa.

In Stock

Schneider Electric · Advantys STB

STBNDN1010

Genuine surplus Schneider STBNDN1010 Advantys STB DeviceNet NIM — verified condition, tested, and ready to ship for legacy…

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: TSXCTY2A

We reply within one business day.

TSXCTY2A Quote reply within 1 business day