Technical specifications
| Protocols | DeviceNet |
|---|---|
| Built-in ports | 5-pin connector (DeviceNet) |
| Supply voltage | 24V DC |
| Addressable I/O modules | max 32 per island |
| Protection rating | IP20 |
| Dimensions (H×W×D) | 128.3 × 70 × 40 mm |
| Weight | 0.145 kg |
| Features | No hot-swap support, no RS232 debug port |
| Lifecycle | Discontinued (superseded by Modicon X80 range) |
Description
When a DeviceNet island loses its network interface, the whole I/O segment goes silent and every downstream module becomes unreachable. The Schneider Electric STBNDN1010 is the basic network interface module for the Advantys STB family, and because it is discontinued, genuine surplus stock is often the fastest practical route to restoring service. Autronexa supplies verified, tested units for maintenance teams keeping legacy STB islands running.
What This NIM Does on an Advantys STB Island
The module is the head of the island: it presents the STB I/O segment to the control network over a 5-pin DeviceNet connector and manages up to 32 addressable I/O modules per island. That ceiling matters during service planning, because a replacement NIM must match the existing island layout rather than force a re-architecture. The unit runs on 24V DC and carries an IP20 protection rating, so it belongs inside an enclosure rather than on the plant floor. Its 128.3 × 70 × 40 mm housing and 0.145 kg weight keep the DIN-rail footprint compact. Note that this basic variant has no hot-swap support and no RS232 debug port, so plan a controlled stop before swapping it and use the island’s normal diagnostics rather than a serial service port.

Why Surplus Fits a Discontinued NIM
Schneider Electric lists this module as discontinued and superseded by the Modicon X80 range. That status is the practical problem: a like-for-like replacement keeps the existing wiring, addressing and panel layout untouched, while a migration to a different platform means engineering time and downtime on a line that may not justify it. Autronexa’s refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team, so you receive a genuine part with known condition instead of an unknown pull. For maintenance engineers, that shortens the path from fault to running island and avoids paying new-platform prices for a legacy segment.
Sourcing Checks Before You Order
Confirm the exact model and connector type first: this is the DeviceNet NIM, not another Advantys STB network head, and the 5-pin connector must match your existing trunk. Check that your island stays within the 32-module limit and that the 24V DC supply is present and correct at the head. Because the module has no hot-swap support, schedule the replacement during a planned stop. Please verify current lifecycle status and availability with Autronexa before ordering, and tell us your island configuration so we can confirm the unit suits it. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric STBNDN1010, or a clone?
Autronexa supplies genuine surplus and refurbished units. Each module is checked against OEM datasheet markings and part-number cross-reference before it enters stock, so the DeviceNet NIM you receive is a real Schneider Electric part, not a copy.
What condition will the STBNDN1010 arrive in?
Units ship in the site default condition, Refurbished — tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need the specific condition noted on a particular unit before purchase.
How fast can you ship this DeviceNet NIM?
Lead time depends on current stock at the time of your request. Contact Autronexa with your part number and required quantity for verified condition and current availability; in-stock surplus units are ready to ship.
Does the STBNDN1010 support hot-swap or a debug port?
No. This basic NIM has no hot-swap support and no RS232 debug port, per the manufacturer data. Plan a controlled stop for replacement and rely on the island's normal diagnostics rather than a serial service connection.
Is the STBNDN1010 still supported by Schneider Electric?
The module is listed as discontinued and superseded by the Modicon X80 range. Contact Autronexa to verify OEM support status and to confirm surplus availability for your Advantys STB island.
Related & compatible parts
Schneider Electric
BMXP3420102CL
Genuine surplus Schneider Electric BMXP3420102CL processor module for Modicon M340 — verified condition, sourcing support, faster than OEM…
Schneider Electric
TM2DRA16RT
Genuine surplus Schneider Electric TM2DRA16RT discrete output module — 16 relay outputs, verified condition, ready to ship.
Schneider Electric
ATV930D11N4Z
Genuine surplus Schneider ATV930D11N4Z variable speed drive — 11 kW ND, dual-rated, verified condition and clear lead times…
Schneider Electric
BMXNOR0200
Genuine surplus BMXNOR0200 RTU serial module for Modicon X80 — verified condition, Modbus RTU connectivity, ready to ship.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…