Schneider Electric I/O & Function Modules Advantys STB

Schneider Electric STBNDN2212

Module

Manufacturer: Schneider Electric Part Number: STBNDN2212

Genuine surplus STBNDN2212 DeviceNet NIM for Advantys STB islands — verified condition, 32 I/O modules per island, ready to ship.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Protocols DeviceNet
Built-in ports 5-pin connector (DeviceNet) + RS232 debug port
Supply voltage 24V DC
Addressable I/O modules max 32 per island
Protection rating IP20
Dimensions (H×W×D) 128.3 × 70 × 40 mm
Weight 0.145 kg
Features Hot-swap support, built-in RS232 debug port
Lifecycle Discontinued (superseded by Modicon X80 range)

Description

When a DeviceNet island loses its network head, every I/O slice behind it goes dark. The STBNDN2212 from Schneider Electric is the Advantys STB standard network interface module that keeps that island talking — a 24V DC NIM with a 5-pin DeviceNet connector and a built-in RS232 debug port. Autronexa supplies it as genuine surplus, verified before dispatch.

What This Advantys STB Interface Module Does

The NIM is the head of an Advantys STB island: it owns the DeviceNet link and manages the I/O slices fanned out behind it. This unit addresses up to 32 I/O modules per island, so a single head covers a full slice stack rather than forcing a split into multiple network nodes. The 5-pin DeviceNet connector carries both network and power to the island, and the separate RS232 debug port gives technicians a local channel for diagnostics without disturbing the running network.

Hot-swap support matters on a live line. Slices can be changed without pulling power from the whole island, which shortens the window between fault detection and restart. The housing measures 128.3 × 70 × 40 mm and weighs 0.145 kg, with an IP20 protection rating — it belongs inside an enclosure, not on an open machine frame. Supply is 24V DC.

Figure 1: Front view of the Schneider Electric STBNDN2212 Module showing its physical design and enclosure.

Discontinued Status and the Surplus Case

Schneider Electric has discontinued this NIM, superseded by the Modicon X80 range. That changes the sourcing question. A new-from-OEM order is no longer the route; buyers are choosing between leftover stock, untested pulls, and verified surplus. Autronexa refurbishes and verifies these units against OEM datasheet specifications, so the part arrives functionally checked rather than as an unknown pull from a decommissioned panel.

For an island still running DeviceNet, migrating the whole architecture to X80 is a project, not a spare-part decision. Keeping the existing head alive with a genuine surplus unit is the practical path — and it avoids the premium that follows a discontinued part number. Contact Autronexa with your part number for verified condition and current availability.

Sourcing Checklist Before You Order

Confirm the island is DeviceNet, not another fieldbus — this NIM will not serve a different network. Check that your slice count stays within the 32-module limit. If you are replacing a failed head, note the existing wiring at the 5-pin connector before removal so the replacement drops in without re-termination errors. Integration Note: wiring into such networks may require an external gateway or connection module — confirm required cables and gateways with your supplier.

Compare your options plainly: OEM new stock is unavailable for a discontinued model; grey-market pulls carry no test record; Autronexa surplus arrives verified, with condition stated before purchase. Please verify current lifecycle status and availability with Autronexa before ordering.

📄 Download Datasheet: STBNDN2212-datasheet.pdf

Frequently asked questions

Is this STBNDN2212 a genuine Schneider Electric module or a copy?

It is a genuine Schneider Electric unit. Autronexa verifies each module against OEM datasheet markings and part-number cross-reference before it enters stock, so the DeviceNet NIM you receive matches the original specification.

What condition will the module arrive in?

Units ship in refurbished condition as the site default — tested against OEM datasheet specifications and functionally verified by our sourcing team. Any specific grading on a unit is stated before purchase.

How fast can you ship this discontinued NIM?

Lead time depends on current stock at the time of your request. Contact Autronexa with the part number for verified condition and current availability; surplus and refurbished stock is ready to ship once confirmed.

Will it work with my existing DeviceNet island?

The module provides a 5-pin DeviceNet connector and supports up to 32 addressable I/O modules per island. Confirm your island runs DeviceNet rather than another fieldbus before ordering, and check cabling and gateway requirements with your supplier.

Is the STBNDN2212 still supported by Schneider Electric?

Schneider Electric lists it as discontinued, superseded by the Modicon X80 range. Autronexa can confirm current availability of verified surplus units; contact us to check stock before committing to a migration project.

Related & compatible parts

Schneider Electric

ATV320U30N4W

Genuine surplus Schneider ATV320U30N4W 3 kW IP66 drive with C2 EMC filter — verified condition and clear lead…

In Stock

Schneider Electric

BMXART0814

Genuine surplus Schneider BMXART0814 8-channel RTD/thermocouple input module — verified condition, faster than OEM lead time.

In Stock

Schneider Electric

140CPS21400

Genuine surplus Schneider 140CPS21400 power supply for Modicon Quantum — verified condition, faster lead time than OEM.

In Stock

Schneider Electric

TM5NS31

Genuine surplus Schneider Electric TM5NS31 Sercos III module — verified, tested, and ready to ship for Modicon LMC078…

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: STBNDN2212

We reply within one business day.

STBNDN2212 Quote reply within 1 business day