Schneider Electric I/O & Function Modules Advantys STB

Schneider Electric STBNDP1010

Module

Manufacturer: Schneider Electric Part Number: STBNDP1010

Genuine surplus Schneider Electric STBNDP1010 Advantys STB network interface module — PROFIBUS DP, verified condition, ready to ship.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Protocols PROFIBUS DP
Built-in ports 9-pin SUB-D (DB-9S)
Supply voltage 24V DC
Addressable I/O modules max 32 per island
Protection rating IP20
Dimensions (H×W×D) 128.3 × 70 × 40 mm
Weight 0.145 kg
Lifecycle Discontinued (superseded by Modicon X80 range)

Description

The Schneider Electric STBNDP1010 is a Basic Network Interface Module for the Advantys STB distributed I/O family, connecting up to 32 I/O modules to a PROFIBUS DP network. Maintenance and procurement teams running legacy Advantys STB islands need this discontinued NIM to keep existing lines communicating — and genuine surplus stock is often the only practical route. Autronexa supplies verified surplus and refurbished units with clear condition reporting.

What This Network Interface Module Does

The STBNDP1010 acts as the head of an Advantys STB island. It carries a 9-pin SUB-D (DB-9S) port for PROFIBUS DP and manages up to 32 addressable I/O modules per island, so one interface module governs the whole slice stack. It runs from a 24V DC supply and measures 128.3 × 70 × 40 mm at 0.145 kg, with an IP20 protection rating suited to cabinet-mounted installations. Because Schneider Electric has discontinued this model in favour of the Modicon X80 range, the interface module is no longer available new from the OEM — which makes condition-verified surplus the realistic replacement path. Please verify current lifecycle status and availability with Autronexa before ordering.

Figure 1: Front view of the Schneider Electric STBNDP1010 Module showing its physical design and enclosure.

Why Genuine Surplus Fits This Discontinued NIM

With the Advantys STB NIM discontinued and superseded by Modicon X80, OEM lead time is not an option — there is no new-build supply. That changes the sourcing question from price to authenticity. Autronexa’s refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team, so the PROFIBUS DP port and 24V DC supply behaviour are checked before dispatch. Genuine parts, verified: each unit is cross-referenced by part number and marking rather than pulled from unlabelled grey-market stock. For plants holding Advantys STB islands in service, this keeps a proven architecture running without a full platform migration.

Sourcing Checklist Before You Order

Confirm the exact model and revision on your existing interface module before ordering, since This unit belongs to a wider Advantys STB family with several NIM variants. Check that your island still uses PROFIBUS DP and the 9-pin SUB-D connection, and note the 32-module island limit when planning expansions. Decide between surplus and refurbished condition based on whether the unit is a like-for-like spare or a long-term hold item. Autronexa can confirm condition, markings, and current availability against your part number — practical sourcing help from a team that works with these systems daily. Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: STBNDP1010-datasheet.pdf

Frequently asked questions

Is this a genuine Schneider Electric STBNDP1010, or a clone?

Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished Schneider Electric modules, not unlabelled copies.

What condition will the STBNDP1010 arrive in?

Our default condition is Refurbished: units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need surplus condition instead.

How fast can you ship this Advantys STB interface module?

Lead time depends on current stock. Contact Autronexa for the present lead time and availability on your required quantity.

Does the STBNDP1010 work with our existing PROFIBUS DP network?

The module provides a 9-pin SUB-D (DB-9S) port for PROFIBUS DP and supports up to 32 addressable I/O modules per island. Confirm your network settings and cabling against your system documentation.

Is the STBNDP1010 still supported by Schneider Electric?

Schneider Electric lists this model as discontinued, superseded by the Modicon X80 range. Contact Autronexa to verify OEM support status and replacement options.

Related & compatible parts

Schneider Electric

BMXXBC120K

Genuine surplus Schneider Electric BMXXBC120K 12 m X-bus expansion cable for Modicon X80 — verified condition, ready to…

In Stock

Schneider Electric · Advantys STB

STBAVI1270

Genuine surplus STBAVI1270: 2-channel ±10V analog input for Advantys STB. Verified condition, faster than OEM lead time.

In Stock

Schneider Electric

690MCB00000

Genuine surplus Schneider Electric 690MCB00000 field wiring block for Modicon Quantum motion control — 50 screw terminals, verified…

In Stock

Schneider Electric

PC-E984-385

Genuine surplus Schneider Electric PC-E984-385 programmable controller — verified Modicon unit with 16k memory and Modbus/Modbus+ ports.

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: STBNDP1010

We reply within one business day.

STBNDP1010 Quote reply within 1 business day