Schneider Electric I/O & Function Modules Advantys STB
Schneider Electric STBNDP2212
Module
Genuine surplus Schneider STBNDP2212 Advantys STB network interface module — PROFIBUS DP, 24V DC, verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Protocols | PROFIBUS DP |
|---|---|
| Built-in ports | 9-pin SUB-D (DB-9S) |
| Supply voltage | 24V DC |
| Addressable I/O modules | max 32 per island |
| Protection rating | IP20 |
| Dimensions (H×W×D) | 128.3 × 70 × 40 mm |
| Weight | 0.145 kg |
| Lifecycle | Discontinued (superseded by Modicon X80 range) |
Description
When a PROFIBUS DP island loses its network interface, every I/O slice behind it goes dark and the line stops. The STBNDP2212 from Schneider Electric is the Advantys STB standard network interface module that restores that link — a discontinued part that Autronexa supplies as genuine surplus, verified before dispatch.
What This Advantys STB Interface Does
The module sits at the head of an Advantys STB island and connects the I/O slices to a PROFIBUS DP network. Its built-in 9-pin SUB-D (DB-9S) port is the physical connection point, and the island can address up to 32 I/O modules behind it. Supply voltage is 24V DC. Physically it measures 128.3 × 70 × 40 mm and weighs 0.145 kg, with an IP20 protection rating suited to cabinet-mounted installations. For maintenance teams keeping an existing STB island running, the network interface is the single point that must match the installed architecture — a substitute from another family will not drop into the same slot.

Why Surplus Makes Sense for a Discontinued NIM
Schneider Electric has discontinued this module and points users toward the Modicon X80 range. That lifecycle status is exactly where surplus sourcing earns its place: a migration to X80 is a project, while a failed NIM on a running island is an outage. Autronexa stocks genuine surplus and refurbished units of this interface, each tested against OEM datasheet specifications and functionally verified by our sourcing team before it is offered. You get a part that matches the original configuration rather than a redesigned platform, and you avoid the lead time of a full range changeover. Condition is stated clearly on every quote, and current availability is confirmed before you commit.
Sourcing Checklist Before You Order
Confirm the exact model on the failed unit’s label — this is the standard NIM for Advantys STB, and the PROFIBUS DP variant is what the DB-9S port and protocol line describe. Check that your island’s I/O count stays within the 32-module limit so the replacement matches the installed layout. Decide whether surplus or refurbished condition fits your maintenance policy; both are genuine parts, verified. Ask for the unit’s markings and part-number cross-reference if your procurement process requires documented authenticity. Because the range is discontinued, please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this STBNDP2212 a genuine Schneider Electric module or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it is listed. The module is supplied as genuine surplus or refurbished stock, not as a copy.
What condition will the module arrive in?
Units are supplied in the site default condition, Refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Any specific grading is confirmed on your quote.
How fast can you ship this network interface module?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability before ordering.
Does this module work with a PROFIBUS DP network?
Yes — the built-in 9-pin SUB-D (DB-9S) port and PROFIBUS DP protocol are the interface this module provides. Confirm your island's I/O count stays within the 32-module limit.
Is the STBNDP2212 still supported by Schneider Electric?
Schneider Electric lists this module as discontinued, superseded by the Modicon X80 range. Contact Autronexa to verify OEM support status and current availability.
Related & compatible parts
Schneider Electric
ATV320U15N4WS
Genuine surplus Schneider ATV320U15N4WS: 1.5 kW, IP65 wall-mount VSD with disconnect switch and C2 EMC filter. Verified condition,…
Schneider Electric · Advantys STB
STBDDO3200
Genuine surplus Schneider STBDDO3200 2-channel digital output module — discontinued Advantys STB part, verified and ready to ship.
Schneider Electric
ATV71H075N4
Genuine surplus Schneider Electric ATV71H075N4 Altivar 71 drive, 0.75 kW, 380–480 V, verified and ready to ship.
Schneider Electric
ATV320U30N4W
Genuine surplus Schneider ATV320U30N4W 3 kW IP66 drive with C2 EMC filter — verified condition and clear lead…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…