Schneider Electric I/O & Function Modules Advantys STB

Schneider Electric STBNDP2212

Module

Manufacturer: Schneider Electric Part Number: STBNDP2212

Genuine surplus Schneider STBNDP2212 Advantys STB network interface module — PROFIBUS DP, 24V DC, verified condition, ready to ship.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Protocols PROFIBUS DP
Built-in ports 9-pin SUB-D (DB-9S)
Supply voltage 24V DC
Addressable I/O modules max 32 per island
Protection rating IP20
Dimensions (H×W×D) 128.3 × 70 × 40 mm
Weight 0.145 kg
Lifecycle Discontinued (superseded by Modicon X80 range)

Description

When a PROFIBUS DP island loses its network interface, every I/O slice behind it goes dark and the line stops. The STBNDP2212 from Schneider Electric is the Advantys STB standard network interface module that restores that link — a discontinued part that Autronexa supplies as genuine surplus, verified before dispatch.

What This Advantys STB Interface Does

The module sits at the head of an Advantys STB island and connects the I/O slices to a PROFIBUS DP network. Its built-in 9-pin SUB-D (DB-9S) port is the physical connection point, and the island can address up to 32 I/O modules behind it. Supply voltage is 24V DC. Physically it measures 128.3 × 70 × 40 mm and weighs 0.145 kg, with an IP20 protection rating suited to cabinet-mounted installations. For maintenance teams keeping an existing STB island running, the network interface is the single point that must match the installed architecture — a substitute from another family will not drop into the same slot.

Figure 1: Front view of the Schneider Electric STBNDP2212 Module showing its physical design and enclosure.

Why Surplus Makes Sense for a Discontinued NIM

Schneider Electric has discontinued this module and points users toward the Modicon X80 range. That lifecycle status is exactly where surplus sourcing earns its place: a migration to X80 is a project, while a failed NIM on a running island is an outage. Autronexa stocks genuine surplus and refurbished units of this interface, each tested against OEM datasheet specifications and functionally verified by our sourcing team before it is offered. You get a part that matches the original configuration rather than a redesigned platform, and you avoid the lead time of a full range changeover. Condition is stated clearly on every quote, and current availability is confirmed before you commit.

Sourcing Checklist Before You Order

Confirm the exact model on the failed unit’s label — this is the standard NIM for Advantys STB, and the PROFIBUS DP variant is what the DB-9S port and protocol line describe. Check that your island’s I/O count stays within the 32-module limit so the replacement matches the installed layout. Decide whether surplus or refurbished condition fits your maintenance policy; both are genuine parts, verified. Ask for the unit’s markings and part-number cross-reference if your procurement process requires documented authenticity. Because the range is discontinued, please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: STBNDP2212-datasheet.pdf

Frequently asked questions

Is this STBNDP2212 a genuine Schneider Electric module or a clone?

Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it is listed. The module is supplied as genuine surplus or refurbished stock, not as a copy.

What condition will the module arrive in?

Units are supplied in the site default condition, Refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Any specific grading is confirmed on your quote.

How fast can you ship this network interface module?

Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability before ordering.

Does this module work with a PROFIBUS DP network?

Yes — the built-in 9-pin SUB-D (DB-9S) port and PROFIBUS DP protocol are the interface this module provides. Confirm your island's I/O count stays within the 32-module limit.

Is the STBNDP2212 still supported by Schneider Electric?

Schneider Electric lists this module as discontinued, superseded by the Modicon X80 range. Contact Autronexa to verify OEM support status and current availability.

Related & compatible parts

Schneider Electric

ATV320U15N4WS

Genuine surplus Schneider ATV320U15N4WS: 1.5 kW, IP65 wall-mount VSD with disconnect switch and C2 EMC filter. Verified condition,…

In Stock

Schneider Electric · Advantys STB

STBDDO3200

Genuine surplus Schneider STBDDO3200 2-channel digital output module — discontinued Advantys STB part, verified and ready to ship.

In Stock

Schneider Electric

ATV71H075N4

Genuine surplus Schneider Electric ATV71H075N4 Altivar 71 drive, 0.75 kW, 380–480 V, verified and ready to ship.

In Stock

Schneider Electric

ATV320U30N4W

Genuine surplus Schneider ATV320U30N4W 3 kW IP66 drive with C2 EMC filter — verified condition and clear lead…

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: STBNDP2212

We reply within one business day.

STBNDP2212 Quote reply within 1 business day