Schneider Electric I/O & Function Modules
Schneider Electric 140ARI03010C
Analogue input module
Genuine surplus Schneider Electric 140ARI03010C analogue input module — 8 differential inputs, 13-bit resolution, verified condition and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Analogue Inputs | 8, differential |
|---|---|
| Input Resolution | 13-bit |
| Input Impedance | >= 10 MOhm |
| Power Dissipation | 1 W |
| Operating Temperature | 32…140 °F (0…60 °C) |
| Storage Temperature | -40…185 °F (-40…85 °C) |
| Relative Humidity | 95 % without condensation |
| Operating Altitude | <= 16404.2 ft (5000 m) |
| Certifications | CE, UL 508, CSA C22.2 No. 142, FM Class 1 Division 2 |
Description
The 140ARI03010C is a Schneider Electric analogue input module for the Modicon Quantum platform. Maintenance and automation teams choose it when they need eight differential analogue inputs with 13-bit resolution and want a genuine surplus or refurbished unit that is verified before dispatch, not a grey-market substitute.
What This Module Does in a Quantum System
The module sits in a standard Quantum rack and converts field analogue signals into digital values the controller can process. Eight differential inputs reduce common-mode noise, which matters when thermocouples, RTDs or transmitters run near drives and contactors. Resolution is 13 bits, so small changes in a process variable remain visible rather than being rounded away. Local LEDs show bus communication, external faults and per-channel status, letting a technician confirm wiring and channel health without a laptop. Power dissipation is 1 W, so the module adds little heat to an enclosure. The part is RoHS compliant and carries CE marking, UL 508 and CSA C22.2 No. 142 listings, with FM Class 1 Division 2 certification for the stated environment.

Surplus Advantage for This Analogue Module
Quantum systems are long-lived, and OEM lead times for legacy I/O can stretch while a line waits. Autronexa stocks genuine surplus and refurbished Quantum modules so a failed input card does not become a multi-week outage. Each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before it ships. That means channel checks, LED behaviour and bus communication are confirmed, not assumed. You get a verified part at a fraction of the new-list price, with clear lead times instead of an open-ended backorder. For plants running mixed Quantum and newer control platforms, this is a practical way to keep spares on the shelf without overcommitting capital.

Buyer’s Checklist Before You Order
Start with the exact part number and confirm it matches the slot and signal type in your rack. Check whether your application needs the full eight channels or a smaller count, and confirm the field wiring is differential. Review the environmental limits: operation from 32…140 °F (0…60 °C), storage from -40…185 °F (-40…85 °C), and relative humidity up to 95 % without condensation. The module is rated for altitudes up to 16404.2 ft (5000 m). Verify that your panel clearance suits the standard module format. Decide between surplus and refurbished condition based on how critical the loop is, and ask for the verification record. Autronexa can cross-reference your existing card and confirm compatibility before you commit. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine Schneider Electric 140ARI03010C, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. We do not sell clones or unverified copies.
What condition will the module arrive in?
Our default condition is refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available; ask for the condition record for your order.
How fast can you ship the 140ARI03010C?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; we confirm dispatch dates before you order.
Does this module work with my existing Modicon Quantum rack?
It is a standard-format Quantum module with eight differential analogue inputs. Confirm your rack slot and field wiring type with our sourcing team before ordering.
Is the 140ARI03010C still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and availability before you commit to a purchase.
Related & compatible parts
Schneider Electric
140DDO35300C
Genuine surplus Schneider Electric 140DDO35300C: 32 discrete outputs, 24V DC, 4 groups. Verified condition, faster than OEM lead…
Schneider Electric
BMENOP0300
Genuine surplus Schneider Electric BMENOP0300 communication module for Modicon M580 PACs — verified condition, ready to ship.
Schneider Electric
ATV930C13N4
Genuine surplus Schneider ATV930C13N4 drive — 132 kW ND/110 kW HD, dual-rated, verified condition, faster than OEM lead…
Schneider Electric
ATV610U15N4
Genuine surplus Schneider ATV610U15N4 drive, 1.5 kW, 380...460 V three-phase, C3 EMC filter, verified condition and clear lead…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…