Schneider Electric Drives & Inverters
Schneider Electric ATV610U15N4
Variable speed drive
Genuine surplus Schneider ATV610U15N4 drive, 1.5 kW, 380...460 V three-phase, C3 EMC filter, verified condition and clear lead times.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated motor power | 1.5 kW (2 HP) normal duty; 0.75 kW (1 HP) heavy duty |
|---|---|
| Supply voltage | 380...460 V AC, 50/60 Hz, three-phase |
| Maximum continuous output current | 4 A (normal duty) |
| Maximum transient current (60 s) | 4.4 A (normal duty) |
| Integrated EMC filter | Category C3 |
| Integrated HMI | Plain text display terminal VW3A1113 (2 lines, white backlit LCD, RJ45) |
| Digital inputs | 6, 24 V DC (2 can be programmed as pulse inputs) |
| Analog inputs | 3, software-configurable 0...10 V / 0...20 mA |
| Operating temperature | -15...+45 °C without derating; up to +60 °C with power derating |
| Dimensions (H×W×D) | 297 × 145 × 203 mm |
Description
When a pump or fan drive fails on a running process, every hour of downtime adds cost. The ATV610U15N4 from Schneider Electric is a 1.5 kW (2 HP) normal-duty variable speed drive in the Easy Altivar 610 series, built for three-phase 380…460 V supplies. For buyers who need a genuine unit without OEM lead time, Autronexa supplies verified surplus and refurbished stock with clear condition reporting.
What This Drive Does in a Pump or Fan System
The Easy Altivar 610 family targets variable-torque applications, and this unit fits that role directly. Its U/f Vc Quadratic (UFQ) control mode is intended for fans and pumps, while standard and 5-point U/f curves cover other open-loop duties. The drive accepts three-phase asynchronous and synchronous motors in open loop, including PMSM and reluctance motor control per the programming manual.
I/O is generous for a frame size 1 unit: 3 analog inputs configurable for 0…10 V or 0…20 mA, 6 digital inputs at 24 V DC (two can act as pulse inputs), 2 analog outputs, and 3 relay outputs. Slot A accepts an Extended I/O module VW3A3203 or Extended relay module VW3A3204. The integrated plain text display terminal VW3A1113 gives two lines of white backlit LCD for local setup and fault reading.

Technical Specifications That Matter
Three ratings deserve attention before you commit. First, the normal-duty rating is 1.5 kW with 4 A continuous output and 4.4 A transient for 60 s; heavy duty drops to 0.75 kW at 2.2 A continuous and 3.3 A transient. Second, the supply range is 380…460 V AC at 50/60 Hz three-phase, with maximum input current of 5.7 A at 380 V and 4.8 A at 460 V. Third, the integrated C3 EMC filter and DC choke reduce harmonic distortion; an optional passive filter (VW3A460xx) can achieve THDi below 10% per the catalog.
Environmental limits are practical for cabinet mounting: -15…+45 °C without derating, up to +60 °C with derating, 5…95% relative humidity non-condensing, and IP20 protection (IP40 on top). The conformal-coated boards suit 3C3/3S3 chemical and mechanical conditions. Dimensions are 297 × 145 × 203 mm and weight is 3.135 kg. The cooling fan is field-replaceable in under five minutes without special tools, which matters for long-term maintenance.

Why Genuine Surplus Makes Sense Here
A 1.5 kW drive is a high-turnover item, and OEM lead times can stretch when demand spikes. Autronexa stocks surplus and refurbished units that are tested against OEM datasheet specifications and functionally verified by our sourcing team. That means you get a genuine Schneider Electric unit with documented condition, not a grey-market clone.
Before ordering, confirm your motor’s normal-duty or heavy-duty rating, the supply voltage at your site, and whether your application needs the optional PROFIBUS DP V1 module VW3A3607 for Slot A. Also verify the relay output supply meets Overvoltage Category II per IEC/EN 61800-5-1, or plan an isolation transformer. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this ATV610U15N4 a genuine Schneider Electric drive or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. This is a genuine Schneider Electric Easy Altivar 610 drive, supplied as surplus or refurbished stock with condition documented before shipment.
What condition will the drive arrive in?
Our default condition is Refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a specific condition grade or surplus-only unit.
How fast can you ship the ATV610U15N4?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; we confirm ship dates before order placement.
Does this drive support PROFIBUS DP?
The built-in communication is Modbus RTU via two RJ45 ports. PROFIBUS DP V1 is available only by adding the optional module VW3A3607 in Slot A. Confirm your network requirements with Autronexa before ordering.
Is the Easy Altivar 610 line still supported by Schneider Electric?
Official product pages for the Easy Altivar 610 line were active as of October 2026. Please verify current lifecycle status and availability with Autronexa before ordering.
Related & compatible parts
Schneider Electric
140DDI85300
Genuine surplus Schneider Electric 140DDI85300 Modicon Quantum 32-point DC input module — verified condition, faster than OEM lead…
Schneider Electric
TCSESM043F23F0
Genuine surplus Schneider ConneXium managed switch with 4 copper ports, HiPER ring redundancy, and verified condition from Autronexa.
Schneider Electric
140NRP31200
Genuine surplus Schneider Electric 140NRP31200 Ethernet fiber converter — verified, tested, and ready to ship for Modicon Quantum…
Schneider Electric
170INT11000C
Genuine surplus Schneider 170INT11000C Interbus adaptor — verified, tested, and ready to ship for Modicon Momentum systems.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…