| Number of Ports | 2 RS232C non isolated DIN 66020 |
|---|---|
| Electrical Connection | 2 connectors SUB-D 9 |
| Transmission Rate | 19.2 kbit/s |
| Maximum Cable Distance | <65.6 ft (20 m) |
| Message Nesting | 8 levels |
| Buffer Size | 255 I bytes / 255 O bytes |
| Memory Capacity | 128 kB flash, 32 kB RAM |
| Bus Current Requirement | 300 mA |
| Operating Temperature | 32…140 °F (0…60 °C) |
Description
The 140ESI06210 is a Schneider Electric ASCII serial link module for the Modicon Quantum platform, featuring two RS232C ports. Maintenance teams and automation engineers turn to genuine surplus or refurbished units when an OEM lead time threatens production uptime. Autronexa verifies each module against OEM datasheet markings before it ships.
What This Module Does in a Quantum System
The 140ESI06210 provides two non-isolated RS232C serial ports using SUB-D 9 connectors, letting a Quantum CPU exchange ASCII messages with devices such as weigh scales, barcode readers, or legacy operator panels. It supports transmission rates up to 19.2 kbit/s and a maximum cable distance of <65.6 ft (20 m) between devices, so keep serial runs short and route them away from drives and high-current cabling. The module handles message nesting up to 8 levels, a 255-byte input and output buffer, and up to 255 messages with a maximum length of 127 characters plus one checksum. A calendar clock and 128 kB flash / 32 kB RAM support local data logging or time-stamped message handling. It draws 300 mA from the bus and dissipates 2 W, and it requires 12 input and 12 output words of addressing. Software support covers Concept, ProWORX 32, ProWORX NxT, and Unity Pro from version 2 onward.

Why Genuine Surplus Fits This Serial Module
Schneider Electric has moved many Quantum users toward newer platforms, and new-from-OEM availability for This unit can be limited or slow. A verified surplus or refurbished module keeps existing Quantum racks running without a controls migration. Autronexa sources genuine units and functionally verifies them against OEM datasheet specifications; every module is tested for port communication and bus current draw before dispatch. Because these are surplus and refurbished, ready to ship, you avoid the long lead times that often come with a factory order. Each unit is inspected for connector wear and flash memory integrity, and we confirm the exact part number and revision before shipping.

Sourcing Checklist for Maintenance Engineers
Before ordering a unit, confirm the host CPU model and that your application software is at Concept, ProWORX 32, ProWORX NxT, or Unity Pro version 2 or later. Check that the two SUB-D 9 ports match your existing cabling and that your serial devices operate at 19.2 kbit/s or slower. Decide whether you need a surplus unit or a refurbished one — both are genuine, but condition grades differ. Ask for the module’s test record and confirm the calendar clock battery status if time-stamped messages are critical. Autronexa can cross-reference your existing module and verify compatibility before you commit. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this 140ESI06210 a genuine Schneider Electric module or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We do not source grey-market clones.
What condition will the 140ESI06210 arrive in?
Our default condition is refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available; contact us for current condition options.
How fast can you ship the 140ESI06210?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability.
Does this module work with all Modicon Quantum CPUs?
The datasheet lists product compatibility with all Quantum CPUs. Confirm your specific CPU model and software version with Autronexa before ordering.
Is the 140ESI06210 still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and availability.
Related & compatible parts
Schneider Electric
TM258LD42DR
Genuine surplus Schneider Electric TM258LD42DR Modicon M258 controller, 42 I/O, verified condition and clear lead times from Autronexa.
Schneider Electric
PC-A984-145
Genuine surplus Schneider Electric PC-A984-145 Modicon CPU module — 8k user memory, Modbus and Modbus+ ports, verified condition.
Schneider Electric · Advantys STB
STBACI1230
Genuine surplus Schneider STBACI1230 analog input module — 2 channels, 0-20 mA, 12-bit, hot-swappable. Verified condition, ready to…
Schneider Electric
iC60N 2P C40
Genuine surplus Schneider iC60N 2P C40 circuit breaker — 40A C-curve, 6 kA, DIN rail. Verified condition and…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…