Schneider Electric I/O & Function Modules Advantys STB

Schneider Electric STBACI1230

Input module

Manufacturer: Schneider Electric Part Number: STBACI1230

Genuine surplus Schneider STBACI1230 analog input module — 2 channels, 0-20 mA, 12-bit, hot-swappable. Verified condition, ready to ship.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Module type Standard analog input module
Channels 2 single-ended
Signal range 0-20 mA (compatible with 4-20 mA)
Resolution 12 bits
Accuracy ±0.5% FS @25 °C
Response time 5 ms for both channels
Isolation 1500V AC field-to-bus, 30V DC channel-to-channel
Hot swapping Yes
I/O base STBXBA1000 (13.9 mm)
PDM STBPDT3100 (24V DC)

Description

The STBACI1230 is a Schneider Electric Advantys STB standard analog input module with two single-ended 0-20 mA channels and 12-bit resolution. Maintenance and automation teams sourcing this discontinued module need a genuine, verified unit rather than an unverified clone — Autronexa supplies tested surplus and refurbished stock with clear condition notes. This module accepts 0-20 mA current signals, which covers 4-20 mA field devices, and converts them for the Advantys STB bus at 12-bit resolution. Each channel can deliver 100 mA to a field device with electronic short-circuit protection, so a single module can power a loop-powered transmitter without a separate supply. The input filter is a single low-pass at 25 Hz nominal, and both channels respond in 5 ms with a 10 ms update time for two channels. Accuracy is ±0.5% FS at 25 °C with ±0.1% FS typical integral linearity and ±0.01% FS/°C temperature drift. Isolation is 1500V AC field-to-bus and 30V DC channel-to-channel. The module is hot-swappable, which matters on a running line: you can replace a failed unit without dropping the bus. It draws 100 mA at 5V DC from the bus and is rated IP20. It mounts on the STBXBA1000 I/O base (13.9 mm) and is powered via the STBPDT3100 PDM at 24V DC. Schneider has discontinued this module and superseded it with the Modicon X80 range, so new-from-OEM supply is no longer the practical route. That is where genuine surplus matters. Autronexa stocks refurbished units tested against OEM datasheet specifications and functionally verified by our sourcing team, which typically shortens the wait compared with chasing remaining OEM stock or waiting on a migration. Because the part is discontinued, confirm the exact revision and base compatibility before ordering. Compare the STBACI1230 with adjacent Advantys STB analog input options: this unit offers 2 single-ended channels at 12 bits with 0-20 mA range and hot swapping, while higher-channel STB analog modules trade channel count for a wider footprint on the same STBXBA1000 base family. If your application needs more than two loops, verify channel count and base width first. For a like-for-like replacement on an existing STB segment, the two-channel, 0-20 mA configuration here matches the original slot. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.

Figure 1: Front view of the Schneider Electric STBACI1230 Input module showing its physical design and enclosure.

Figure 2: Technical layout and connection details for the Schneider Electric STBACI1230 Input module.

📄 Download Datasheet: STBACI1230-datasheet.pdf

Frequently asked questions

Is this STBACI1230 a genuine Schneider Electric module or a clone?

Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished modules, not grey-market copies.

What condition will the STBACI1230 arrive in?

Our default condition is Refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the specific condition grade on current stock.

How fast can you ship the STBACI1230?

Lead time depends on current stock. Contact Autronexa for current lead time and availability — surplus and refurbished units are ready to ship when in stock.

Does the STBACI1230 work with the STBXBA1000 I/O base and STBPDT3100 PDM?

Yes. The datasheet lists the STBXBA1000 I/O base (13.9 mm) and STBPDT3100 PDM (24V DC) as the associated base and power distribution module for this unit.

Is the STBACI1230 still supported by Schneider Electric?

Schneider has discontinued this module and superseded it with the Modicon X80 range. Contact Autronexa to verify OEM support status and availability of genuine surplus units.

Related & compatible parts

Schneider Electric

ATV610C16N4

Genuine surplus Schneider ATV610C16N4 drive — 160 kW, 380...460 V, C3 EMC filter, Modbus. Verified condition and clear…

In Stock

Schneider Electric

BMECXM0100H

Genuine surplus Schneider Electric BMECXM0100H CANopen module for M580 PLCs — verified condition, practical lead times, sourcing support…

In Stock

Schneider Electric

TSXAEY1600

Genuine surplus TSXAEY1600 analog input module — 16 channels, 12-bit, verified condition, ready to ship from Autronexa.

In Stock

Schneider Electric

iC60N 2P C25

Genuine surplus Schneider Electric iC60N 2P C25 circuit breaker — verified 25A C-curve, 6 kA, DIN rail. Sourced…

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: STBACI1230

We reply within one business day.

STBACI1230 Quote reply within 1 business day