Schneider Electric I/O & Function Modules Advantys STB
Schneider Electric STBACI8320
Input module
Genuine surplus Schneider Electric STBACI8320 HART analog input module — 4 channels, 12-bit, hot-swappable, verified and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Module type | Standard analog input module (HART) |
|---|---|
| Channels | 4 single-ended |
| Signal type | 4-20 mA / 0-20 mA current, HART-compatible |
| Resolution | 12 bits |
| Isolation | 1500V AC field-to-bus |
| Hot swapping | Yes |
| Supply voltage | 24V DC (via PDM) |
| I/O base | STBXBA1000 (13.9 mm) |
| PDM | STBPDT3100 (24V DC) |
| Protection rating | IP20 |
Description
When a HART analog input module fails on a running Advantys STB island, every hour without a replacement adds pressure to production. The Schneider Electric STBACI8320 is a standard 4-channel HART analog current input module for Advantys STB systems, and sourcing a genuine surplus unit keeps your line moving without waiting on OEM lead times.
What This Module Does in an Advantys STB Island
The STBACI8320 is a standard analog input module built for the Advantys STB distributed I/O family. It provides four single-ended input channels accepting 4-20 mA or 0-20 mA current signals with HART compatibility, converting field measurements to 12-bit digital values for the network interface. Field-to-bus isolation is rated 1500V AC, separating instrumentation wiring from the bus side. The module supports hot swapping, so you can replace a faulty unit without shutting down the entire island. It mounts on an STBXBA1000 I/O base (13.9 mm) and receives 24V DC supply through an STBPDT3100 PDM. The unit is compatible with STBNIP, STBNDP, STBNMP, and STBNCO network interface modules, making it a practical drop-in for existing Advantys STB architectures. The IP20 protection rating suits it to cabinet-mounted installations where dust and moisture are controlled.

Why Genuine Surplus Makes Sense for a Discontinued Module
Schneider Electric has discontinued This unit, superseding it with the Modicon X80 range. That lifecycle status changes the sourcing calculation: OEM new stock is no longer the default path, and migrating to a different platform carries engineering and downtime costs. Genuine surplus and refurbished units let you keep the existing Advantys STB island running without a redesign. Autronexa sources these modules through verified channels, checks part-number markings and condition, and tests refurbished units against OEM datasheet specifications before they ship. You get a practical replacement path with clear lead times — not a promise of new-from-OEM availability that no longer exists. For maintenance teams supporting legacy Advantys installations, surplus stock is often the fastest route to a working module.

Buyer’s Checklist Before You Order
Start by confirming the exact model and revision on your existing module — This unit is specific to HART analog input duty, and mixing it with non-HART analog modules in the same island can complicate signal handling. Verify that your I/O base is STBXBA1000 (13.9 mm) and that your PDM is STBPDT3100 (24V DC), since the module draws supply through the PDM rather than directly from the bus. Check which network interface module your island uses — STBNIP, STBNDP, STBNMP, or STBNCO — to confirm compatibility. Decide whether you need a surplus unit or a refurbished one, and ask for the condition grade in writing. Because the module is discontinued, confirm current availability and any accessory requirements with your supplier before committing. Autronexa can cross-reference your part number and provide verified condition details so you order the right unit the first time. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this STBACI8320 a genuine Schneider Electric module or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference. We source genuine surplus and refurbished Schneider Electric modules and disclose condition before shipment.
What condition will the STBACI8320 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available depending on stock. Ask for the specific condition grade when you request a quote.
How fast can you ship the STBACI8320?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability — we confirm lead time before you order.
Will this module work with my existing Advantys STB network interface?
The STBACI8320 is compatible with STBNIP, STBNDP, STBNMP, and STBNCO network interface modules, and mounts on an STBXBA1000 I/O base with an STBPDT3100 PDM. Confirm your exact island configuration with our team if you are unsure.
Is the STBACI8320 still supported by Schneider Electric?
Schneider Electric has discontinued this module and superseded it with the Modicon X80 range. Contact Autronexa to verify OEM support status and availability of genuine surplus stock.
Related & compatible parts
Schneider Electric
140CPS21400C
Genuine surplus Schneider Electric 140CPS21400C power supply for Modicon Quantum — verified condition, tested, ready to ship.
Schneider Electric · Advantys STB
STBNCO2212
Genuine surplus Schneider STBNCO2212 Advantys STB CANopen network interface module — verified condition, ready to ship.
Schneider Electric
TSX3722001
Genuine surplus Schneider Electric TSX3722001 modular base controller — verified condition, tested, and ready to ship from Autronexa.
Schneider Electric
TM3DQ8R
Genuine surplus Schneider TM3DQ8R: 8 relay outputs, 24 V DC, screw terminals. Verified condition, faster than OEM lead…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…