Schneider Electric I/O & Function Modules Advantys STB
Schneider Electric STBACO0120
Output module
Genuine surplus Schneider STBACO0120 analog output module — 1-channel 4-20 mA, 15-bit, hot-swappable, verified and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Module type | Standard analog output module |
|---|---|
| Channels | 1 |
| Signal type | 4-20 mA current |
| Resolution | 15 bits + sign |
| Isolation | 1500V DC field-to-bus |
| Hot swapping | Yes |
| Supply voltage | 24V DC (via PDM) |
| I/O base | STBXBA1000 (13.9 mm) |
| PDM | STBPDT3100 (24V DC) |
| Protection rating | IP20 |
Description
The Schneider Electric STBACO0120 is a standard 1-channel analog current output module for the Advantys STB distributed I/O system, delivering a 4-20 mA signal at 15-bit plus sign resolution. Maintenance teams running existing STB islands need genuine units, not clones, and Autronexa supplies verified surplus and refurbished stock with clear lead times.
What This Module Does in an STB Island
This standard analog output module occupies one position on an STB I/O base and drives a single 4-20 mA current loop — the signal format most valve positioners, variable-frequency drives and analog panel meters expect. Resolution of 15 bits plus sign gives the loop fine control steps, which matters when a small output change moves a control valve. Field-to-bus isolation is rated 1500V DC, separating the current loop from the island bus so a field wiring fault does not propagate into the communication side. The module is hot-swappable, so a maintenance engineer can replace it with the island powered, provided site procedures permit live work. It draws 24V DC through the PDM, and the reference configuration pairs it with the STBXBA1000 I/O base at 13.9 mm width and the STBPDT3100 PDM. The housing carries an IP20 protection rating, so it belongs inside an enclosure, not on an open machine frame.

Sourcing a Discontinued Advantys STB Output Module
Schneider Electric lists this module as discontinued, superseded by the Modicon X80 range. That status changes the sourcing calculation: OEM channels no longer stock it new, and a migration to X80 means re-engineering the rack, wiring and often the control program. For a plant that simply needs to keep an existing STB island running, a tested surplus or refurbished unit is the practical route. Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference, then functionally checks it before dispatch. You get a genuine part with a known condition rather than an unknown-history pull, and the cost sits well below the last OEM list price for this family.

Selection and Service Checks Before You Order
Before committing, confirm the exact model string on your existing module and match it to this listing — the STB family uses several analog output variants that look alike but differ in channel count and signal type. Check that your island uses the STBXBA1000 base and STBPDT3100 PDM, since the module depends on both. Decide whether you need a surplus unit or a refurbished one; both are genuine, and the difference is inspection depth, which our team can explain for your application. On the reliability side, inspect the base contacts and PDM connections at each scheduled maintenance interval, keep the enclosure sealed to preserve the IP20 rating, and follow Schneider Electric’s published safety manual for any replacement work. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this STBACO0120 a genuine Schneider Electric module or a clone?
Every unit is verified against OEM datasheet markings and part-number cross-reference before it enters stock. Autronexa supplies genuine surplus and refurbished Schneider Electric components, not grey-market copies.
What condition will the module arrive in?
Units ship in refurbished condition by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a surplus unit instead and we will confirm what is on hand.
How fast can you ship a discontinued Advantys STB output module?
Lead time depends on current stock. Contact Autronexa with the part number for verified condition and current availability before you place the order.
Does this module work with my existing STB island?
It is designed for the Advantys STB system and pairs with the STBXBA1000 I/O base and STBPDT3100 PDM at 24V DC. Confirm your base and PDM part numbers against these before ordering.
Is the STBACO0120 still supported by Schneider Electric?
Schneider Electric lists it as discontinued, superseded by the Modicon X80 range. Contact Autronexa to verify OEM support status and to discuss keeping your existing STB island running.
Related & compatible parts
Schneider Electric
BMXDDI1604T
Genuine surplus Schneider Electric BMXDDI1604T Modicon X80 16-channel 24 V DC input module with per-channel diagnostics, verified and…
Schneider Electric
TSXSUP1011
Genuine surplus Schneider Electric TSXSUP1011 power supply for TSX Micro PLCs — 24 V AC/DC input, 24 V…
Schneider Electric
170ADM35015
Genuine surplus Schneider Electric 170ADM35015 discrete I/O module — 16 sinking inputs, 16 sourcing outputs, verified and ready…
Schneider Electric
BMEP584040S
Genuine surplus BMEP584040S safety processor — verified, tested, and ready to ship from Autronexa.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…