| Module type | Standard analog output module |
|---|---|
| Channels | 2 |
| Signal type | 4-20 mA standard analog output (no HART) |
| Resolution | 15 bits + sign |
| Response time | 4 ms (for both channels) |
| Isolation | 1500V DC field-to-bus |
| Hot swapping | Yes |
| Supply voltage | 24V DC (via PDM) |
| I/O base | STBXBA1000 (13.9 mm) |
| Protection rating | IP20 |
Description
The Schneider Electric STBACO0220 is a standard 2-channel analog current output module for the Advantys STB distributed I/O system, delivering a 4-20 mA signal at 15-bit plus sign resolution. Maintenance and procurement teams running legacy Advantys STB architectures need this module as genuine surplus because the range is discontinued and superseded by Modicon X80. Autronexa supplies verified surplus and refurbished units with practical sourcing support.
Where This Module Fits in an Advantys STB Island
Advantys STB distributed I/O grew out of the industry’s move toward field-mounted, modular control architectures, where machine builders wanted to place I/O close to the process rather than run long home-run cables back to a central cabinet. The STBACO0220 carries that legacy forward as a standard analog output module with two current channels. It produces a 4-20 mA standard analog output with no HART capability, which suits valve positioners, variable-speed drives, and analog indicators that accept a plain current loop. Resolution is 15 bits plus sign, and both channels respond in 4 ms. Field-to-bus isolation is rated 1500V DC, separating the analog side from the island bus. Hot swapping is supported, so a failed channel can be replaced without powering down the entire island. The module mounts on an STBXBA1000 I/O base measuring 13.9 mm and draws 24V DC through an STBPDT3100 PDM. Its IP20 protection rating means it belongs inside an enclosure, not on an exposed machine face.

Why Genuine Surplus Makes Sense for a Discontinued Module
The Advantys STB range is discontinued and superseded by Modicon X80, so ordering this part number through normal OEM channels is no longer a straightforward path. That is exactly where surplus and refurbished stock earns its place. Autronexa sources genuine Schneider Electric units and verifies them against OEM datasheet markings and part-number cross-reference before they reach a buyer. Each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team. For a plant keeping an existing STB island in service, this avoids the cost and downtime of a full platform migration. It also gives maintenance managers a practical alternative to grey-market listings with unknown history. Please verify current lifecycle status and availability with Autronexa before ordering.

Sourcing Checklist Before You Buy
Buyers should confirm three things. First, match the exact model and revision — This unit is a standard analog output module, not a HART-capable variant, so substituting a different STB output module changes the signal behavior. Second, confirm the base and power distribution: this module requires the STBXBA1000 I/O base and the STBPDT3100 24V DC PDM, and neither is included unless stated. Third, agree on condition — surplus versus refurbished — and ask for the verification record. Autronexa can confirm what is in stock and what lead time applies. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this STBACO0220 a genuine Schneider Electric module or a clone?
Autronexa sources genuine Schneider Electric units and verifies each one against OEM datasheet markings and part-number cross-reference before shipping. Ask for the verification details with your quote.
What condition will the STBACO0220 arrive in?
Autronexa supplies this module as refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus condition may also be available — confirm with us before ordering.
How fast can Autronexa ship the STBACO0220?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability before placing an order.
Does the STBACO0220 need a specific base and power module?
Yes. The data specifies an STBXBA1000 I/O base (13.9 mm) and an STBPDT3100 PDM supplying 24V DC. Confirm that both are present in your island before installation.
Is the STBACO0220 still supported by Schneider Electric?
The Advantys STB range is discontinued and superseded by Modicon X80. Contact Autronexa to verify OEM support status and current availability for your application.
Related & compatible parts
Schneider Electric
PC-E984-685
Genuine surplus Schneider Electric PC-E984-685 Modicon controller — verified, tested, and ready to ship with sourcing support.
Schneider Electric
140DDI35310
Genuine surplus Schneider Electric 140DDI35310 32-point DC input module for Modicon Quantum — verified condition, faster lead times…
Schneider Electric
BMENOC0321
Genuine surplus Schneider Electric BMENOC0321 communication module for Modicon M580 — verified condition, ready to ship.
Schneider Electric
ABE7H16S21
Genuine surplus Schneider Electric ABE7H16S21 16-channel sub-base with isolator — verified condition, practical lead times.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…