Schneider Electric I/O & Function Modules
Schneider Electric 170AAI52040
Analog input base
Genuine surplus Schneider Electric 170AAI52040 analog input base — four differential channels, verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Number of Channels | 4 Channels |
|---|---|
| Analog Input Type | Differential |
| Data Format | Full 16 Bits Signed |
| Update Time | 500 ms |
| Isolation Between Channels | 400V DC for 1 Minute |
| Isolation Channels to Ground | 500V AC for 1 Minute |
| Isolation Channels to Bus | 500 Volts for 1 Minute |
| Operating Temperature Range | 0°C to 60°C |
| Storage Temperature Range | -40°C to 85°C |
| Maximum Relative Humidity | 95% Without Condensation |
Description
The Schneider Electric 170AAI52040 is a four-channel differential analog input base for the Modicon Momentum platform, built to acquire field signals at full 16-bit signed resolution. Maintenance and procurement teams choose genuine surplus or refurbished units of this base when an OEM replacement lead time would stall a running line, and Autronexa verifies each unit before it ships.
What This Analog Input Base Does in a Momentum System
The base sits between field wiring and the Momentum I/O assembly, converting differential analog signals into a full 16-bit signed data format that the controller reads on a 500 ms update cycle. Four channels share one base, so a single slot covers a compact group of analog points. Isolation is layered: 400V DC between channels for one minute, 500V AC channel-to-ground for one minute, and 500V channel-to-bus for one minute. Internal reverse polarity protection adds a further layer of resilience against wiring errors. The unit measures 4.9 in high, 5.6 in wide and 1.9 in deep, weighs 0.474 lb (US), and carries the CE marking with TC protective treatment. Operating range is 0°C to 60°C, storage -40°C to 85°C, and maximum relative humidity 95% without condensation.

Why Genuine Surplus Fits This Base
Momentum installations are long-lived, and a failed analog base can idle an entire I/O segment while a factory-new order works through distribution. Surplus and refurbished stock closes that gap. Each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team, so channel count, data format and isolation behaviour are confirmed before dispatch. You gain a shorter path to a working slot and a practical alternative to full OEM list pricing, without accepting unverified grey-market stock. Country of origin for this configuration is ID, and the part is returnable under the stated schedule.

Buyer’s Checklist Before You Order
Confirm the replacement matches your existing Momentum assembly: four differential channels, full 16-bit signed data format, 500 ms update time, and the isolation ratings above. Check the enclosure dimensions against your panel space, and confirm the operating temperature band suits the cabinet environment. Decide whether you need surplus or refurbished condition and ask for the verified condition note. Because lifecycle status is not stated in our data, please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this 170AAI52040 a genuine Schneider Electric unit or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it is listed. The base is supplied as genuine surplus or refurbished stock, not a grey-market copy.
What condition will the analog input base arrive in?
The site default condition is Refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask Autronexa for the condition note on the specific unit before purchase.
How fast can you ship the 170AAI52040?
Lead time is not fixed in our published data. Contact Autronexa with your part number and required quantity for current availability and shipping timing.
Does this base suit my existing Modicon Momentum assembly?
It provides four differential analog input channels in full 16-bit signed format with a 500 ms update time. Confirm your assembly's slot requirements and channel count against these figures before ordering.
Is the 170AAI52040 still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before you commit to an order.
Related & compatible parts
Schneider Electric
170XTS00301
Genuine surplus Schneider Electric 170XTS00301 terminal connector kit for Modicon Momentum — verified condition, ready to ship.
Schneider Electric
ATV312H018M2
Genuine surplus Schneider ATV312H018M2 drive, 0.18 kW single-phase, verified and ready to ship from Autronexa.
Schneider Electric
52-0422-000
Genuine surplus Schneider Electric 52-0422-000 trunk terminator for Modicon Quantum coaxial networks — verified condition, ready to ship.
Schneider Electric
BMXP3420302H
Genuine surplus BMXP3420302H processor module for Modicon M340 — verified condition, faster lead time than OEM, and expert…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…