Technical specifications
| Channels | 16 (2 groups of 8) |
|---|---|
| Output type | Triac (bidirectional thyristor) |
| Signal type | 115/230V AC output |
| Output current | 0.5 A per point |
| Supply voltage | 120/230V AC |
| Isolation | 1780V AC group-to-group |
| Diagnostics | Internal 5 A slow-blow fuse per group (no electronic channel diagnostics) |
| Response time | 1/2 line cycle (≈8.3 ms @ 60 Hz / 10 ms @ 50 Hz) |
| Power consumption | 5 W maximum |
| Dimensions (H×W×D) | 125 × 141.5 × 47.5 mm |
Description
The 170ADO54000 is a Schneider Electric Modicon Momentum discrete output base module with 16 AC Triac channels in two groups of eight. Maintenance teams running legacy Momentum systems need this exact module to restore 115/230V AC switching without redesigning the panel — and genuine surplus stock is often the only realistic path, since the series is discontinued. Autronexa verifies each unit against OEM datasheet markings before it ships.
What This Output Module Does in a Momentum System
This is a discrete output base module, not a processor or input card. It drives AC loads directly from the Momentum bus, with each point rated at 0.5 A and a Triac (bidirectional thyristor) output stage. The 16 channels split into two groups of eight, and each group carries its own internal 5 A slow-blow fuse. That fuse arrangement matters on the floor: there is no electronic channel diagnostics, so a dead group usually points to a blown group fuse rather than a failed channel. Isolation between groups is 1780V AC, which keeps the two eight-point blocks electrically independent. Response time is 1/2 line cycle — roughly 8.3 ms at 60 Hz and 10 ms at 50 Hz — so the module suits contactor coils, small solenoids, and similar AC pilot duty rather than high-speed switching. Supply voltage is 120/230V AC across 47 to 63 Hz, with internal current draw of 125 mA at 120V AC and 65 mA at 230V AC. Maximum power consumption is 5 W. The housing measures 125 × 141.5 × 47.5 mm and weighs 0.35 kg, with an IP20 protection rating for cabinet-mounted use.

Why Genuine Surplus Fits This Discontinued Module
The lifecycle line is unambiguous: this module is discontinued, last verified in September 2026. That changes the sourcing calculation. OEM channel stock for a discontinued Momentum base module is not a reliable plan, and grey-market units with unknown history carry real risk in a live control cabinet. Autronexa holds surplus and refurbished units that are tested against OEM datasheet specifications and functionally verified by our sourcing team. For a maintenance engineer, the practical benefit is straightforward: you replace like-for-like without re-engineering the I/O layout, and you get a verified unit rather than an untested pull. The 5 A group fuse and the 1780V AC group isolation are the two details worth confirming on any replacement, because a mismatched variant will fit the rail but not behave the same way.

Sourcing Checklist Before You Order
Match the full model and confirm the output type is Triac, not relay or transistor — Momentum base modules share a footprint but differ in output stage. Check that your application draws no more than 0.5 A per point and that the load is AC within the 85 to 132V or 164 to 253V windows. Confirm the 47.5 mm depth clears your enclosure door and that IP20 suits the cabinet environment. Because operating, storage, and humidity figures are not published for this configuration, ask Autronexa for verified condition details and current availability before committing. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric 170ADO54000, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before listing. We supply genuine surplus and refurbished modules, not grey-market copies.
What condition will the module arrive in?
Units ship as refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a specific condition grade confirmed.
How fast can you ship this discontinued module?
Lead time depends on current stock. Contact Autronexa for current lead time and availability — the module is discontinued, so we confirm stock before quoting.
Does the 170ADO54000 work with existing Modicon Momentum I/O?
It is a Modicon Momentum discrete output base module with 16 AC Triac channels in two groups of eight. Confirm your backplane and wiring match the 120/230V AC supply and 0.5 A per-point rating before ordering.
Is the module still supported by Schneider Electric?
The lifecycle status is discontinued, last verified in September 2026. Contact Autronexa to verify OEM support status and current availability.
Related & compatible parts
Schneider Electric
BMXDDM16025
Genuine surplus BMXDDM16025 mixed I/O module — 8 DI + 8 relay DO, verified condition, faster than OEM…
Schneider Electric
BMXART0814
Genuine surplus Schneider BMXART0814 8-channel RTD/thermocouple input module — verified condition, faster than OEM lead time.
Schneider Electric
ATV320U30N4WS
Genuine surplus Schneider ATV320U30N4WS: 3 kW, 380–500 V three-phase, IP65 wall-mount drive with disconnect switch and C2 EMC…
Schneider Electric
TM258LF66DT4L
Genuine surplus Schneider Electric TM258LF66DT4L Modicon M258 controller — 66 I/O, 4 analog inputs, verified and ready to…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…