Technical specifications
| Product Line | Modicon Momentum |
|---|---|
| Current Rating | 4 to 20 mA |
| Voltage Rating | 0 to 10 V DC |
| Number of Inputs | 4 |
| Number of Outputs | 2 |
| Weight | 0.50 lbs (0.23 kg) |
| Ambient Temperature Range | 0 to 40 degrees Celsius |
| Operating Humidity | Up to 80% RH (non-condensing) |
| Maximum Operating Altitude | 1000 meters above sea level without derating |
Description
When an analog signal path fails on a running Modicon Momentum system, every hour of downtime adds pressure. The Schneider Electric 170BAM09600 I/O module keeps data interfacing moving with four inputs and two outputs, and Autronexa supplies it as a genuine surplus or refurbished unit — verified before it ships. Maintenance teams choose it to restore signal handling without waiting on OEM lead times.
What This Module Does in a Momentum System
The 170BAM09600 is an analog I/O module from Schneider Electric’s Modicon Momentum line. It handles current signals in the 4 to 20 mA range and voltage signals from 0 to 10 V DC, so it can interface with transmitters, sensors and controllers that use either convention. Four inputs and two outputs give it enough channels for compact control loops. The module weighs 0.50 lbs (0.23 kg), which keeps panel space and mounting load low. Ambient temperature must stay between 0 and 40 degrees Celsius, and humidity up to 80% RH is acceptable as long as it remains non-condensing. At altitudes up to 1000 meters above sea level, the unit operates without derating — a useful margin for plants in lowland or coastal locations.

Surplus Advantage for This I/O Module
OEM lead times on Modicon Momentum components can stretch when a specific analog variant is not on the shelf. Autronexa keeps verified surplus and refurbished stock of Schneider Electric I/O modules, and each unit is checked against OEM datasheet specifications and functionally verified by our sourcing team. That means you get a genuine part with a known condition, not a grey-market substitute. For This unit, the practical benefit is straightforward: restore analog signal handling on an existing Momentum rack without paying a brand-new list price or waiting through a long factory order. If your maintenance window is tight, ask our team about current availability and lead time before you commit.

Buyer’s Checklist Before You Order
Before purchasing this module, confirm the exact part number on your existing unit and match it to unit. Check that your application uses 4 to 20 mA current loops or 0 to 10 V DC voltage signals, and count the inputs and outputs you need — four inputs and two outputs are fixed on this model. Review your panel’s ambient conditions: the module is rated for 0 to 40 degrees Celsius and up to 80% RH non-condensing, so a hotter enclosure may need extra ventilation. If you are replacing a failed unit, note any revision markings on the old module and share them with our sourcing team. Autronexa can confirm condition, accessory compatibility and current lifecycle status before you order. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric 170BAM09600, or a clone?
Autronexa supplies genuine surplus and refurbished units. Each module is verified against OEM datasheet markings and part-number cross-reference before it is listed or shipped.
What condition will the 170BAM09600 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact us for the specific condition of the unit currently in stock.
How fast can you ship the 170BAM09600?
Lead time depends on current stock. Contact Autronexa for current lead time and availability before placing your order.
Does this module work with my existing Modicon Momentum system?
The 170BAM09600 is part of the Modicon Momentum line and handles 4 to 20 mA current and 0 to 10 V DC voltage signals with four inputs and two outputs. Confirm your rack and signal type match before ordering.
Is the 170BAM09600 still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability.
Related & compatible parts
Schneider Electric
140NOM21100C
Genuine surplus Schneider Electric 140NOM21100C DIO head-end adaptor for Modicon Quantum — verified condition, Modbus RS-485/RS-232, ready to…
Schneider Electric
TSX-P57-204M
Genuine surplus Schneider Electric TSX-P57-204M Unity processor for Modicon Premium — verified condition, tested, ready to ship.
Schneider Electric
BMEP581020H
Genuine surplus BMEP581020H processor module for Modicon M580 — verified condition and fast lead times from Autronexa.
Schneider Electric
BMXP3420302
Genuine surplus Schneider Electric BMXP3420302 processor module for Modicon M340 — verified condition, practical lead times, engineering sourcing…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…