Schneider Electric I/O & Function Modules
Schneider Electric 170DDI16001
Module Modicon Momentum 16-channel 24V DC
Genuine surplus Schneider Electric 170DDI16001 Modicon Momentum 16-channel 24V DC input module — verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Channels | 16 |
|---|---|
| Signal type | 24V DC, true high |
| Input type | DC |
| Supply voltage | 24V DC (19.2 to 30V) |
| Power consumption | 3 W maximum |
| Protection rating | IP20 |
| Dimensions (H×W×D) | 125 × 141.5 × 47.5 mm |
| Weight | 0.35 kg |
| Certifications | CE, UL, CSA |
Description
When a Modicon Momentum I/O base fails, every hour of downtime erodes throughput and maintenance budget. The Schneider Electric 170DDI16001 is a 16-channel 24V DC discrete input base module from the Modicon Momentum series, and Autronexa supplies it as genuine surplus — verified condition, ready to ship, and priced below OEM list.
What This Input Base Module Does on Your Panel
The 170DDI16001 accepts 16 discrete 24V DC signals with a true-high input type, so field devices such as limit switches, pushbuttons, and proximity sensors report their state directly to the Momentum controller without external signal conditioning. That direct interface removes the cost of interposing relays and extra terminal blocks from every channel. The module operates from a 24V DC supply spanning 19.2 to 30V, giving your panel tolerance for the voltage sag that appears when contactors and drives switch on the same DC bus. At 3 W maximum power consumption, the module adds little heat to an enclosure, which matters in densely packed cabinets where cooling capacity is already committed. The IP20 protection rating suits installation inside a controlled cabinet rather than on the machine frame, so plan panel space accordingly. Physical dimensions of 125 × 141.5 × 47.5 mm and a 0.35 kg weight make the unit straightforward to handle during replacement without disturbing adjacent wiring.

Why Genuine Surplus Fits This Discontinued Module
Schneider Electric lists this model as discontinued, last verified in 2026-09. That status changes the sourcing math: OEM channels no longer produce new units, and waiting on a distributor allocation can stall a planned maintenance window. Genuine surplus stock already in the market avoids that wait and typically costs less than the last published list price for new stock. Each unit Autronexa supplies is tested against OEM datasheet specifications and functionally verified by our sourcing team, so you receive a part whose 16 channels, 24V DC input range, and 3 W power draw match the original specification. For a discontinued base module, that verification is the difference between a working replacement and a second failure.
Sourcing Checklist Before You Order
Confirm the exact model string on your existing module matches unit, since Modicon Momentum base modules share a footprint but differ in channel count and signal type. Check that your application needs 16 discrete DC inputs at true-high logic and that the 19.2 to 30V supply range covers your panel voltage. Verify cabinet space against the 125 × 141.5 × 47.5 mm dimensions and confirm the IP20 rating is acceptable for the installed location. Decide whether you need a single replacement or a stocked spare, because discontinued modules become harder to source over time. Autronexa can confirm condition, certification markings (CE, UL, CSA), and current availability from stock. Please verify current lifecycle status and availability with Autronexa before ordering.
Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this 170DDI16001 a genuine Schneider Electric module or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. The module carries CE, UL, and CSA certification markings as listed in the datasheet.
What condition will the module arrive in?
Units are supplied as refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the specific condition grade of current stock.
How fast can you ship the 170DDI16001?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability before committing to a maintenance window.
Does this module work with my existing Modicon Momentum controller?
The 170DDI16001 is a Modicon Momentum discrete input base module with 16 channels at 24V DC true-high logic. Confirm your controller's base module compatibility and slot configuration against your system documentation before ordering.
Is the 170DDI16001 still supported by Schneider Electric?
The model is listed as discontinued, last verified in 2026-09. Autronexa can confirm current availability from surplus stock; please verify OEM support status with Schneider Electric for long-term planning.
Related & compatible parts
Schneider Electric
140NOE21100C
Genuine surplus Schneider Electric 140NOE21100C TCP/IP module for Modicon Quantum — verified condition, faster than OEM lead times.
Schneider Electric
TSXCAY33
Genuine surplus Schneider Electric TSXCAY33 motion control module for servo motors — verified condition, faster lead times than…
Schneider Electric
140CPU67260
Genuine surplus Schneider Electric 140CPU67260 Unity Hot Standby processor — verified condition, faster lead times than OEM, and…
Schneider Electric
TM5SAI4L
Genuine surplus Schneider Electric TM5SAI4L analog input module — 4 channels, 12-bit, verified condition and ready to ship…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…