Technical specifications
| Application | For servo motors |
|---|---|
| Type of Axis | 2/3 axis linear interpolation |
| Operating Modes | OFF, FOLLOWER, Manual, Direct drive mode, Automatic |
| Speed Profile Path | Trapezoidal or parabolic |
| Resolution | ≤ 1000 position units per point, ≥ 0.5 position units per point |
| Acquisition Speed | ≤ 270,000 points/min, ≥ 54,000 points/min |
| Acceleration Time | 8 ms to 10 s |
| Power Dissipation | 10–17 W |
| Input Voltage | 24 V 8 mA auxiliary input, 24 V 8 mA servo drive control input, 5 V 18 mA counter input |
| Weight | 1.00 lbs (0.45 kg) |
Description
The Schneider Electric TSXCAY33 is a motion control module for servo motors within the TSX Micro PLCs series, handling 2/3 axis linear interpolation. Maintenance and automation teams choose genuine surplus or refurbished units like this when OEM lead times stretch and a verified spare is needed to keep servo-driven machinery running. Autronexa supplies tested, traceable units with practical sourcing support.
What This Module Does in a Servo Axis
The TSXCAY33 manages position, speed, and acceleration for up to three axes. It supports five operating modes — OFF, FOLLOWER, Manual, Direct drive mode, and Automatic — so the same module can serve setup, jogging, and full automatic production. The servo loop uses proportional overshoot compensation and gain switching, while the speed profile follows a trapezoidal or parabolic path. Resolution spans ≤ 1000 position units per point down to ≥ 0.5 position units per point, letting you tune fine positioning where the mechanics allow it. Acquisition speed reaches ≤ 270,000 points/min with a lower bound of ≥ 54,000 points/min, and acceleration time is adjustable from 8 ms to 10 s. Input compatibility covers absolute SSI encoders at 12–25 bits, incremental encoders at 10–30 V totem pole or 5 V DC RS422, and 2-wire/3-wire sensors at 24 V DC. The module dissipates 10–17 W and runs on a 24 V DC auxiliary and servo drive control supply with a 5 V DC counter input. These specs suit machine builders and integrators who need coordinated multi-axis motion without replacing the entire control platform.

Surplus and Refurbished Advantage for This Module
Sourcing a unit through OEM channels can mean long lead times for a module that is often part of a legacy TSX Micro PLCs installation. Autronexa keeps genuine surplus and refurbished units in stock, tested against OEM datasheet specifications and functionally verified by our sourcing team. That means you get a module with documented condition and clear lead times, rather than waiting on a factory order or accepting an unverified grey-market part. For maintenance managers, the practical benefit is straightforward: a verified spare arrives faster, at a cost below OEM list price, and you can plan the repair window around a known delivery date. Because this module supports multiple encoder types and three axes, keeping a tested spare on the shelf reduces the risk of a single failed axis halting a production line. Autronexa’s sourcing engineers work with Schneider Electric systems daily and can confirm the exact configuration you need before shipment.

Selection and Sourcing Guide
Before ordering, verify the exact model and revision against your existing module. Confirm the encoder type in use — SSI absolute at 12–25 bits, incremental totem pole at 10–30 V, incremental RS422 at 5 V DC, or 2-wire/3-wire sensor at 24 V DC — because This unit supports several input configurations and you want the one that matches your wiring. Check the operating mode requirements: OFF, FOLLOWER, Manual, Direct drive mode, or Automatic. Also confirm the axis count (2/3 axis linear interpolation) and the power dissipation range (10–17 W) against your cabinet thermal budget. When comparing surplus versus refurbished, ask for the condition grade and test report. Autronexa provides verified condition details and current availability on request. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine Schneider Electric TSXCAY33, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished modules, not grey-market copies.
What condition will the TSXCAY33 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact us for the specific condition grade of current stock.
How fast can you ship the TSXCAY33?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; we confirm shipping dates before you order.
Does this module work with my existing encoders?
The TSXCAY33 supports absolute SSI encoders at 12–25 bits, incremental encoders at 10–30 V totem pole or 5 V DC RS422, and 2-wire/3-wire sensors at 24 V DC. Confirm your encoder type against these options before ordering.
Is the TSXCAY33 still supported by Schneider Electric?
Lifecycle status is not stated in our data. Please verify current lifecycle status and availability with Autronexa before ordering.
Related & compatible parts
Schneider Electric
ATV71HU22N4
Genuine surplus Schneider ATV71HU22N4 Altivar 71 drive, 2.2 kW, 380-480 VAC. Verified condition, faster lead time than OEM.
Schneider Electric
ATV930U15N4
Genuine surplus Schneider ATV930U15N4 Altivar 930 drive — dual-rated 1.5 kW ND / 0.75 kW HD, verified condition…
Schneider Electric
BMXAMO0802
Genuine surplus BMXAMO0802: 8-channel Modicon X80 analog output, 12-bit, verified and ready to ship.
Schneider Electric
STBNIP2212
Genuine surplus Schneider Electric STBNIP2212 Modbus TCP/IP network interface module — verified condition, sourcing help, faster than OEM…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…