Siemens 3RW4427-1BC44
Soft starter Values at 400 V
Genuine Siemens 3RW4427-1BC44 SIRIUS soft starter, 93 A at 400 V, with integrated bypass and inside-delta capability. Verified surplus stock.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated operating current, standard circuit at 40 °C | 93 A |
|---|---|
| Motor output, standard circuit at 400 V, 40 °C | 45 kW |
| Rated operating current, inside-delta at 40 °C | 161 A |
| Motor output, inside-delta at 400 V, 40 °C | 90 kW |
| Operating voltage | 200–460 V AC |
| Control supply voltage | 230 V AC, 50/60 Hz |
| Integrated bypass contact system | Yes |
| Motor overload protection | Yes |
| Main circuit connection | Box terminal, screw fixing |
| Protection class | IP00 |
Description
A plant engineer needed to start a 90 kW motor on a 400 V network without upgrading the upstream protection. The standard circuit rating of the Siemens 3RW4427-1BC44 is 93 A at 40 °C, but its inside-delta configuration raises the usable motor output to 90 kW. That single feature often decides whether a soft starter fits an existing cabinet. Autronexa supplies this SIRIUS unit as a genuine surplus or refurbished component, verified against OEM markings before dispatch.
What the 3RW4427-1BC44 Delivers in Practice
This unit is a SIRIUS soft starter for three-phase motors, rated 200–460 V AC with a 230 V AC control supply. In the standard circuit it carries 93 A at 40 °C and drives a 45 kW motor at 400 V. Switch to the inside-delta circuit and the same frame handles 161 A at 40 °C, enough for a 90 kW motor at 400 V. An integrated bypass contact system keeps the thyristors out of the circuit once the motor reaches full speed, which reduces heat inside the enclosure. Motor overload protection, thermistor evaluation and adjustable current limitation are built in, so the starter covers protection functions that would otherwise need separate components.

Why Genuine Surplus Suits This Soft Starter
Soft starters sit in the power path, so a clone or mislabelled unit is a real risk to the motor and the upstream breaker. Autronexa sources This unit as genuine surplus and refurbished stock, and every unit is checked against the OEM datasheet before it ships. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. For a model with this current range, that verification matters more than a sealed box. Buyers also avoid the long lead times that often apply when ordering a single soft starter through standard OEM channels. Surplus and refurbished, ready to ship.

Sourcing Checks Before You Order
Confirm three things before committing to a unit. First, match the circuit: the 93 A standard rating and the 161 A inside-delta rating are not interchangeable, and the motor cabling must suit the chosen arrangement. Second, check the control supply: this unit expects 230 V AC at 50 or 60 Hz. Third, review the terminal type, since the main circuit uses box terminals with screw fixing and the auxiliary circuit uses screw terminals. Autronexa can confirm condition, revision markings and current availability from the part number alone. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Siemens 3RW4427-1BC44 or a copy?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before dispatch. The 3RW4427-1BC44 is supplied as genuine surplus or refurbished stock, not as a clone.
What condition will the 3RW4427-1BC44 arrive in?
Units are supplied refurbished as standard, tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask Autronexa for the current condition grade on the specific unit available.
How fast can Autronexa ship the 3RW4427-1BC44?
Lead time depends on current stock. Contact Autronexa with the part number for verified condition and current availability before placing an order.
Does the 3RW4427-1BC44 support inside-delta motor connection?
Yes. The inside-delta circuit is rated 161 A at 40 °C and supports a 90 kW motor at 400 V, while the standard circuit is rated 93 A at 40 °C for 45 kW at 400 V.
Related & compatible parts
Siemens
1FK7022-5AK71-1LH0
Genuine surplus Siemens 1FK7022-5AK71-1LH0 servo motor with 0.38kW, 6000rpm, and IP64 protection. Verified condition and ready to ship…
Siemens
3RW4423-1BC44
Genuine Siemens 3RW4423-1BC44 soft starter, surplus and refurbished, verified for 36A standard duty and 62A inside-delta operation.
Siemens
3RW4055-6BB44
Genuine surplus Siemens 3RW4055-6BB44 soft starter, 134 A at 40 °C, verified and ready for three-phase motor control.
Siemens
3RW4444-6BC44
Genuine Siemens 3RW4444-6BC44 soft starter for 250 A standard or 433 A inside-delta operation, sourced as verified surplus…
News & guides for Siemens
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Siemens and NVIDIA’s Erlangen Blueprint: 85% Less Ramp-Up Engineering
Siemens and NVIDIA are turning the Erlangen electronics plant into a blueprint for AI-run factories. What the 85% and 20%…
Siemens spare parts: buying guide, series overview and how to order
Siemens spare parts buying guide: 4 parts online, popular series, condition options and how our RFQ process works.
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…