Siemens 3RW4426-1BC44
Soft starter
Genuine surplus Siemens 3RW4426-1BC44 soft starter, 77 A at 40 °C and 37 kW at 400 V, verified and ready for reliable motor starting.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Operating current at 40 °C (standard circuit) | 77 A |
|---|---|
| Rated power at 400 V (standard circuit) | 37 kW |
| Operating current at 40 °C (inside-delta circuit) | 133 A |
| Rated power at 400 V (inside-delta circuit) | 75 kW |
| Operating voltage (standard circuit) | 200–460 V AC |
| Control supply voltage | 230 V AC at 50/60 Hz |
| Terminal type | Screw terminals (control), box terminals (main) |
| Protection class | IP00 |
| Dimensions (W × H × D) | 170 × 192 × 270 mm |
Description
The Siemens 3RW4426-1BC44 is a SIRIUS soft starter rated 77 A at 40 °C and 37 kW at 400 V, built for standard circuit motor starting. Maintenance teams and panel builders choose genuine surplus or refurbished units to replace failed starters without long OEM lead times. Autronexa verifies every unit against OEM datasheet markings before it ships.
What the 3RW4426-1BC44 Delivers in a Motor Circuit
This soft starter sits between the supply and a three-phase motor, limiting inrush current during start-up. This unit carries a 77 A rating at 40 °C in standard circuit and delivers 37 kW at 400 V. Its integrated bridging contact system and thyristors handle the switching, while intrinsic device protection and motor overload protection are built in. A display provides fault signalling, and external reset is supported for remote fault clearing. The unit also evaluates thermal resistor motor protection, so it can respond to motor winding temperature.

Technical Specs That Matter for Sizing
Three values guide most selection decisions. First, the operating voltage range of 200–460 V AC with standard circuit covers common three-phase supplies. Second, the inside-delta circuit rating reaches 133 A and 75 kW, giving higher capacity when the motor windings are connected for root switching. Third, the control supply voltage is 230 V AC at 50 or 60 Hz, so the control circuit must match this value. This unit uses screw terminals for control wiring and box terminals for main current connections, accepting conductor cross-sections up to 70 mm² stranded. Mounting is by screw fixing, and the IP00 protection class means the starter must be installed inside an enclosure.

Why Genuine Surplus Fits This Soft Starter
Siemens SIRIUS soft starters are widely used in pumping, conveying and fan systems, so replacement demand is steady. When a unit fails, waiting for a new OEM build can extend downtime. Autronexa supplies genuine surplus and refurbished unit units that are tested against OEM datasheet specifications and functionally verified by our sourcing team. Each unit is checked for correct terminal condition and fault display operation. Because these are surplus and refurbished components, availability can be faster than factory lead times, and the practical condition is stated clearly before purchase. Contact Autronexa with your part number for verified condition and current availability.
Buyer Checklist Before You Order
Confirm the motor full-load current at your ambient temperature and compare it with the 77 A rating at 40 °C. Verify whether your application uses standard or inside-delta circuit, because This unit supports both. Check that your control supply is 230 V AC and that the enclosure provides the required clearances. Finally, confirm the exact part number and any revision markings on your existing unit. Autronexa can cross-reference your requirements and provide a verified surplus or refurbished replacement.
Frequently asked questions
Is the Siemens 3RW4426-1BC44 a genuine Siemens product or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished Siemens soft starters, not grey-market copies.
What condition will the 3RW4426-1BC44 arrive in?
Units are supplied as refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available; condition is stated clearly before purchase.
How fast can Autronexa ship the 3RW4426-1BC44?
Lead time depends on current stock. Contact Autronexa for current lead time and availability; surplus and refurbished units are often ready to ship faster than factory orders.
Does the 3RW4426-1BC44 support inside-delta circuit connection?
Yes. The 3RW4426-1BC44 is rated for inside-delta circuit at 133 A and 75 kW, in addition to standard circuit at 77 A and 37 kW.
Related & compatible parts
Siemens
1FK7022-5AK71-1LH0
Genuine surplus Siemens 1FK7022-5AK71-1LH0 servo motor with 0.38kW, 6000rpm, and IP64 protection. Verified condition and ready to ship…
Siemens
6SL3243-0BB30-1PA3
Siemens 6SL3243-0BB30-1PA3 I/O & Function Modules. Switching level: 0→1 11 V; Switching level: 1→0 5 V. New surplus…
Siemens
3RW4056-6BB44
Genuine surplus Siemens 3RW4056-6BB44 SIRIUS S6 soft starter, 162 A at 40 °C, 90 kW at 400 V,…
Siemens
3RT6015-1BB42
Genuine surplus Siemens 3RT6015-1BB42 contactor: 7 A AC-3, 3 kW at 400 V, 24 V DC coil, 1…
News & guides for Siemens
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Siemens and NVIDIA’s Erlangen Blueprint: 85% Less Ramp-Up Engineering
Siemens and NVIDIA are turning the Erlangen electronics plant into a blueprint for AI-run factories. What the 85% and 20%…
Siemens spare parts: buying guide, series overview and how to order
Siemens spare parts buying guide: 4 parts online, popular series, condition options and how our RFQ process works.
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…