Siemens 3RW4056-6BB44
Switching / at 40 °C
Genuine surplus Siemens 3RW4056-6BB44 SIRIUS S6 soft starter, 162 A at 40 °C, 90 kW at 400 V, verified and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated operating current at 40 °C | 162 A |
|---|---|
| Rated power at 400 V | 90 kW |
| Operating voltage range | 200 … 460 V AC |
| Control supply voltage | 230 V AC at 50/60 Hz |
| Frame size | S6 |
| Ambient operating temperature | -25 … +60 °C |
| Main circuit connection | Busbar connection |
| Auxiliary connection | Screw-type terminals |
| Auxiliary contacts | 2 NO, 1 changeover |
Description
When a soft starter fails on a running motor line, every hour of downtime adds cost. The Siemens 3RW4056-6BB44 SIRIUS S6 soft starter delivers 162 A at 40 °C and 90 kW at 400 V, and genuine surplus stock shortens the wait for a verified replacement.
What the 3RW4056-6BB44 Does in a Motor Circuit
This unit is a SIRIUS S6 soft starter for standard applications. It controls three-phase motors with a rated operating voltage of 200 … 460 V AC and a rated operating current of 162 A at 40 °C. The device includes integrated bridging contact system and thyristors, plus intrinsic device protection and motor overload protection. A practical benefit for maintenance teams is the adjustable current limitation, which helps manage inrush during starts. The unit also provides two NO auxiliary contacts and one changeover contact for status signaling. Screw terminals handle auxiliary and control wiring, while the main current circuit uses busbar connection.

Reliability and Service Notes from the Floor
For maintenance engineers, This unit offers features that simplify troubleshooting. The fault signal is a red display, so a quick panel check identifies a trip without opening the enclosure. External reset is supported, which means a technician can clear a fault from the cabinet door rather than reaching into the device. The ambient operating range of -25 … +60 °C suits typical industrial cabinets, and the derating temperature is 40 °C, so current capacity should be reviewed when cabinet temperatures run higher. The S6 frame uses screw fixing, and the mounting position allows tilt and rotation within the limits stated in the datasheet. Periodic inspection of terminal torque and cooling airflow remains the practical routine for long service life.

Why Genuine Surplus Fits This Soft Starter
OEM lead times for large-frame soft starters can stretch when production slots are full. Autronexa supplies genuine surplus and refurbished Siemens automation components, with each unit verified against OEM datasheet markings before dispatch. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. That approach gives maintenance planners a practical alternative to waiting on a new-build unit, without accepting unverified grey-market stock. Because This unit uses standard screw terminals and busbar connections, swap-out follows the same wiring layout as the original device. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Siemens 3RW4056-6BB44 or a clone?
Every 3RW4056-6BB44 we supply is checked against OEM datasheet markings and part-number cross-references. Autronexa deals in genuine surplus and refurbished Siemens components, not copies.
What condition will the 3RW4056-6BB44 arrive in?
Units are supplied refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the current condition grade of available stock.
How fast can you ship the 3RW4056-6BB44?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability before ordering.
Does the 3RW4056-6BB44 suit a 400 V motor application?
The datasheet rates this SIRIUS S6 soft starter at 90 kW at 400 V and 162 A at 40 °C, with an operating voltage range of 200 … 460 V AC. Confirm your motor full-load current and cabinet temperature against these ratings.
Related & compatible parts
Siemens
3RW4075-6BB44
Genuine Siemens 3RW4075-6BB44 SIRIUS S12 soft starter, 356 A at 40 °C and 200 kW at 400 V.…
Siemens
3RW4426-1BC44
Genuine surplus Siemens 3RW4426-1BC44 soft starter, 77 A at 40 °C and 37 kW at 400 V, verified…
Siemens
3RW4422-1BC44
Genuine surplus Siemens 3RW4422-1BC44 soft starter, verified and tested. 29 A at 400 V, 15 kW standard, 50…
Siemens
3RW4425-1BC44
Genuine Siemens 3RW4425-1BC44 soft starter, 57A/30kW standard, 99A/55kW inside-delta. Verified surplus and refurbished units ready to ship.
News & guides for Siemens
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Siemens and NVIDIA’s Erlangen Blueprint: 85% Less Ramp-Up Engineering
Siemens and NVIDIA are turning the Erlangen electronics plant into a blueprint for AI-run factories. What the 85% and 20%…
Siemens spare parts: buying guide, series overview and how to order
Siemens spare parts buying guide: 4 parts online, popular series, condition options and how our RFQ process works.
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…