Siemens 3RW4073-6BB44
Soft starter S12 230 A
Genuine surplus Siemens 3RW4073-6BB44 SIRIUS S12 soft starter, 230 A at 40 °C and 132 kW at 400 V, verified and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated operational current at 40 °C | 230 A |
|---|---|
| Rated power at 400 V, standard circuit, 40 °C | 132 kW |
| Operating voltage at standard circuit | 200 ... 460 V AC |
| Control supply voltage at AC | 230 V |
| Operating frequency | 50 ... 60 Hz |
| Dimensions (W x H x D) | 160 x 230 x 278 mm |
| Degree of protection | IP00 |
| Ambient temperature during operation | -25 ... +60 °C |
Description
The Siemens 3RW4073-6BB44 is a SIRIUS S12 soft starter rated 230 A at 40 °C and 132 kW at 400 V, built for three-phase motor starting in standard circuit. Maintenance teams and panel builders choose genuine surplus or refurbished units when OEM lead times stretch, because a verified replacement keeps the line running without a full-price new purchase.
What the S12 Soft Starter Does in Your Panel
The 3RW4073-6BB44 sits between the supply and a three-phase motor, ramping current at start-up instead of applying full line voltage. Its integrated bypass contact system and thyristors carry the load once the motor reaches speed, so the starter does not need a separate bypass contactor. Rated operational current is 230 A at 40 °C, and the device delivers 132 kW at 400 V in standard circuit. A red fault display gives a local indication when the starter trips, which shortens troubleshooting on the panel floor. The unit is phased out by Siemens; the preferred successor type is 3RW5073-6AB14, so plan replacements accordingly.

Why Genuine Surplus Fits This Phased-Out Model
Because Siemens lists This unit as a phased-out product, new-from-OEM stock is limited and successor migration takes engineering time. A genuine surplus or refurbished S12 unit lets you keep the existing panel design, wiring and documentation unchanged. Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference, and refurbished stock is tested against the datasheet and functionally verified before dispatch. That approach gives you a practical bridge while you plan a move to the 3RW5 family, without committing to a full redesign today.

Sourcing Checks Before You Order
Confirm the exact model and revision on your existing unit, then match the operational current to your motor load. This unit is rated 230 A at 40 °C, so ambient temperature inside the enclosure matters; check the mounting position and required clearances against your panel layout. Decide whether you need surplus or refurbished condition and confirm accessory compatibility, since auxiliary contact blocks and terminal hardware must match the S12 frame. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Siemens 3RW4073-6BB44 or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference. The 3RW4073-6BB44 is supplied as genuine surplus or refurbished stock, not as a copy.
What condition will the 3RW4073-6BB44 arrive in?
Units are supplied as refurbished by default, tested against the OEM datasheet specifications and functionally verified by our sourcing team. Surplus condition may also be available; confirm the grading you need when you request a quote.
How fast can you ship the 3RW4073-6BB44?
Contact Autronexa for current lead time. Stock levels for phased-out Siemens SIRIUS S12 units change often, so we confirm availability before quoting.
Is the 3RW4073-6BB44 still supported by Siemens?
Siemens lists this model as a phased-out product. The preferred successor type is 3RW5073-6AB14. Contact Autronexa to verify OEM support status and migration options.
Related & compatible parts
Siemens
1FK7022-5AK71-1LH0
Genuine surplus Siemens 1FK7022-5AK71-1LH0 servo motor with 0.38kW, 6000rpm, and IP64 protection. Verified condition and ready to ship…
Siemens
3RV6021-4CA15
Genuine surplus Siemens 3RV6021-4CA15 circuit breaker with 11–16 A overload release and transverse auxiliary switch, verified and ready…
Siemens
3RW4427-1BC44
Genuine Siemens 3RW4427-1BC44 SIRIUS soft starter, 93 A at 400 V, with integrated bypass and inside-delta capability. Verified…
Siemens
6SL3243-0BB30-1PA3
Siemens 6SL3243-0BB30-1PA3 I/O & Function Modules. Switching level: 0→1 11 V; Switching level: 1→0 5 V. New surplus…
News & guides for Siemens
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Siemens and NVIDIA’s Erlangen Blueprint: 85% Less Ramp-Up Engineering
Siemens and NVIDIA are turning the Erlangen electronics plant into a blueprint for AI-run factories. What the 85% and 20%…
Siemens spare parts: buying guide, series overview and how to order
Siemens spare parts buying guide: 4 parts online, popular series, condition options and how our RFQ process works.
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…