Siemens 3RW4425-1BC44
Soft starter
Genuine Siemens 3RW4425-1BC44 soft starter, 57A/30kW standard, 99A/55kW inside-delta. Verified surplus and refurbished units ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated operating current at 40 °C (standard) | 57 A |
|---|---|
| Rated operating current at 40 °C (inside-delta) | 99 A |
| Rated power at 400 V (standard) | 30 kW |
| Rated power at 400 V (inside-delta) | 55 kW |
| Operating voltage | 200 … 460 V AC |
| Control supply voltage | 230 V AC at 50/60 Hz |
| Operating frequency | 50 … 60 Hz |
| Protection class | IP00 |
Description
Industrial motor control has evolved from simple electromechanical starters to sophisticated solid-state soft starters that reduce mechanical stress and extend equipment life. The Siemens 3RW4425-1BC44 SIRIUS soft starter represents this evolution, delivering controlled acceleration for three-phase motors with integrated bridging contacts and thyristors. For maintenance teams facing an unexpected failure, sourcing a genuine 3RW4425-1BC44 quickly is critical to restoring production. Autronexa supplies verified surplus and refurbished units, offering a practical alternative to long OEM lead times without compromising authenticity.
Product Overview
This unit is a SIRIUS soft starter for high-feature applications, designed for standard and inside-delta circuit configurations. It handles rated operating currents of 57 A at 40 °C in standard circuit and 99 A at 40 °C in inside-delta circuit. The corresponding rated mechanical power at 400 V is 30 kW in standard circuit and 55 kW in inside-delta circuit. This flexibility allows one device to serve different motor sizes, simplifying spare-parts inventory. The soft starter includes integrated bridging contact system and thyristors, plus intrinsic device protection and motor overload protection. It also supports thermal resistor motor protection evaluation and external reset, making it adaptable to various control schemes.

Surplus Advantage
When a soft starter fails, OEM lead times can stretch to weeks, leaving production lines idle. Autronexa maintains a stock of genuine surplus and refurbished Siemens unit units, each tested against OEM datasheet specifications and functionally verified by our sourcing team. Refurbished units are inspected for component integrity and performance, ensuring they meet the original operating parameters. This approach delivers cost savings compared to new OEM list price and faster availability, without the risks of grey-market clones. Our team understands the SIRIUS family and can help you confirm compatibility with your existing control panel.

Selection & Sourcing Guide
Before ordering, verify the exact model and revision required for your application. This unit supports operating voltages from 200 to 460 V AC and control supply voltages of 230 V AC at 50 or 60 Hz. Check whether your motor is wired in standard or inside-delta configuration, as the current and power ratings differ accordingly. Also confirm the ambient temperature at the installation site, since derating applies above 40 °C. Autronexa provides clear condition grading and lead times for each unit. Contact us with your part number for verified condition and current availability. We also assist with cross-referencing and technical questions to ensure you receive the right part.
Frequently asked questions
Is this a genuine Siemens 3RW4425-1BC44, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We supply only genuine surplus and refurbished components, never grey-market copies.
What condition will the 3RW4425-1BC44 arrive in?
Our default condition is refurbished, meaning the unit has been tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available; condition is stated clearly on each quote.
How fast can you ship the 3RW4425-1BC44?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; we provide clear lead times before you order.
Does the 3RW4425-1BC44 work with my existing motor protection setup?
The soft starter includes motor overload protection and evaluation of thermal resistor motor protection. Confirm your control voltage is 230 V AC and your motor wiring matches either standard or inside-delta circuit.
Related & compatible parts
Siemens
6ES7422-1BL00-0AA0
Siemens 6ES7422-1BL00-0AA0 Cables & Connectors. Power loss, typ: 4 W; Width: 25 mm. Supplied for MRO and OEM…
Siemens
6SL3243-0BB30-1PA3
Siemens 6SL3243-0BB30-1PA3 I/O & Function Modules. Switching level: 0→1 11 V; Switching level: 1→0 5 V. New surplus…
Siemens
3RV6021-4CA15
Genuine surplus Siemens 3RV6021-4CA15 circuit breaker with 11–16 A overload release and transverse auxiliary switch, verified and ready…
Siemens
3RW4434-6BC44
Genuine Siemens 3RW4434-6BC44 soft starter, surplus and refurbished, verified for 200–460 V AC operation with 113 A at…
News & guides for Siemens
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Siemens and NVIDIA’s Erlangen Blueprint: 85% Less Ramp-Up Engineering
Siemens and NVIDIA are turning the Erlangen electronics plant into a blueprint for AI-run factories. What the 85% and 20%…
Siemens spare parts: buying guide, series overview and how to order
Siemens spare parts buying guide: 4 parts online, popular series, condition options and how our RFQ process works.
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…