Siemens 3RW4424-1BC44
Soft starter
Genuine Siemens 3RW4424-1BC44 soft starter, 47A at 40°C, 22kW at 400V. Verified surplus and refurbished units from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Operating current at 40 °C (standard circuit) | 47 A |
|---|---|
| Rated power at 400 V (standard circuit) | 22 kW |
| Operating current at 40 °C (inside-delta circuit) | 81 A |
| Rated power at 400 V (inside-delta circuit) | 45 kW |
| Operating voltage | 200 … 460 V AC |
| Control supply voltage | 230 V AC |
| Operating frequency | 50 … 60 Hz |
| Ambient temperature during operation | 60 °C |
| Protection class | IP00 |
| Electrical connection | Screw terminals |
Description
When a 22kW motor on a 400V system needs controlled acceleration, the Siemens 3RW4424-1BC44 soft starter delivers 47A at 40°C in standard circuit. This genuine SIRIUS unit also supports inside-delta connection for 81A and 45kW. Autronexa supplies verified surplus and refurbished units for maintenance teams who need authentic parts without OEM lead times. Public datasheet parameters are limited for this configuration — our sourcing team can provide verified specs on request.
What the 3RW4424-1BC44 Does in a Motor Circuit
This unit is a SIRIUS soft starter for high-feature applications. It limits starting current and reduces mechanical stress on three-phase motors. The device includes integrated bridging contacts and thyristors, plus intrinsic device protection and motor overload protection. An external reset and adjustable current limitation are available. The inside-delta circuit option lets you run a larger motor from the same frame: 81A and 45kW at 400V. The unit accepts 200–460V AC main voltage and 230V AC control supply. Screw terminals handle main and control wiring. Three normally open auxiliary contacts and one changeover contact support interlocking and status signaling.

Why Genuine Surplus Makes Sense for This Soft Starter
OEM lead times for soft starters can stretch when production slots are full. A tested surplus or refurbished unit keeps your motor protection project on schedule. Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. You get genuine parts, verified, with clear lead times. This unit is a practical match for panels already built around the SIRIUS family, since dimensions and terminal layout follow the standard SIRIUS design.

Selection and Sourcing Checks Before You Order
Confirm the exact model and revision match your panel drawings. Check whether your motor runs in standard or inside-delta circuit, because the current ratings differ: 47A standard versus 81A inside-delta. Verify the control supply is 230V AC at 50 or 60Hz. Decide between surplus and refurbished condition based on your maintenance window. Ask for the unit’s test record and any accessory items included. Autronexa provides sourcing help across Allen-Bradley, Bently Nevada, Siemens, Schneider and more. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Siemens 3RW4424-1BC44, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished Siemens soft starters, not grey-market copies.
What condition will the 3RW4424-1BC44 arrive in?
Units are supplied as refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus condition may also be available — confirm with Autronexa before ordering.
How fast can you ship the 3RW4424-1BC44?
Contact Autronexa for current lead time. We confirm availability and dispatch timing for each verified unit before you commit.
Does the 3RW4424-1BC44 support inside-delta circuit connection?
Yes. The 3RW4424-1BC44 supports inside-delta circuit connection with ratings of 81A and 45kW at 400V, in addition to the standard circuit rating of 47A and 22kW.
Related & compatible parts
Siemens
3RW4444-6BC44
Genuine Siemens 3RW4444-6BC44 soft starter for 250 A standard or 433 A inside-delta operation, sourced as verified surplus…
Siemens
3RW4056-6BB44
Genuine surplus Siemens 3RW4056-6BB44 SIRIUS S6 soft starter, 162 A at 40 °C, 90 kW at 400 V,…
Siemens
3RW4434-6BC44
Genuine Siemens 3RW4434-6BC44 soft starter, surplus and refurbished, verified for 200–460 V AC operation with 113 A at…
Siemens
3RW4076-6BB44
Genuine surplus Siemens 3RW4076-6BB44 soft starter, S12 432 A at 40 °C, 250 kW/400 V. Verified condition and…
News & guides for Siemens
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Siemens and NVIDIA’s Erlangen Blueprint: 85% Less Ramp-Up Engineering
Siemens and NVIDIA are turning the Erlangen electronics plant into a blueprint for AI-run factories. What the 85% and 20%…
Siemens spare parts: buying guide, series overview and how to order
Siemens spare parts buying guide: 4 parts online, popular series, condition options and how our RFQ process works.
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…