Technical specifications
| Digital inputs | 24 (3 groups of 8) |
|---|---|
| Digital transistor outputs | 16 (2 groups of 8) |
| Digital inputs/outputs | 8 (1 group) |
| Analog inputs | 8 |
| Analog outputs | 4 |
| Rated supply voltage | 24 V DC |
| Current consumption | max. 0.35 A |
| Integrated memory | Flash EPROM 512 kB, RAM 2 MB |
| Dimensions (W x H x D) | 240 x 140 x 85 mm |
| Weight | 1.6 kg |
Description
When a critical Advant Controller fails, every hour of downtime erodes production and maintenance budgets. Sourcing a verified, genuine ABB 07 KT 94 — the GJR5252100R0161 variant with 24 digital inputs, 16 transistor outputs, 8 configurable digital I/O, 8 analog inputs, and 4 analog outputs — from surplus stock gets your line back online without the lead-time uncertainty of a factory order.
What This Controller Delivers on the Plant Floor
The 07 KT 94 sits at the heart of ABB Advant control architectures, handling mixed digital and analog signal processing for machinery, process skids, and remote I/O clusters. Its CS31 system bus expands to as many as 31 remote modules, supporting up to 992 digital inputs, 992 digital outputs, and 224 analog channels each way — enough headroom for distributed control without adding another CPU. The integrated high-speed hardware counter runs in 7 operating modes with a counting range of -32768…+32767 and a maximum frequency of 50 kHz, using inputs E 62,00 and E 62,01. Two serial interfaces serve programming or man-machine communication, while the parallel special interface accepts a communication processor for networking with other bus systems. With 2 MB RAM and 512 kB Flash EPROM, the unit holds programs and user data locally, and the real-time clock resolves to 1 second.

Why Genuine Surplus Beats Waiting on a Factory Order
ABB Advant controllers are mature platform components, and OEM lead times for spares can stretch weeks or months — a timeline most maintenance teams cannot absorb. Autronexa stocks surplus and refurbished units that are tested against OEM datasheet specifications and functionally verified by our sourcing team. Every unit we ship is genuine parts, verified against ABB markings and part-number cross-reference, so you are not gambling on grey-market clones. The practical benefit is simple: you get a known-condition controller with clear lead times, at a fraction of the cost of a new OEM list price. For plants running legacy Advant systems, this surplus channel is often the only realistic way to keep spares on the shelf.

Sourcing Checklist Before You Commit
Not every Advant controller listing tells you what you need to know. Before ordering, confirm the exact part number — GJR5252100R0161 — matches your existing unit, and verify the I/O count aligns with your application: 24 digital inputs, 16 transistor outputs, 8 digital I/O, 8 analog inputs, and 4 analog outputs. Ask whether the unit is surplus or refurbished, and request the test documentation. Check that the removable screw-type terminal blocks are included, since wiring method affects installation time. The module mounts on DIN EN 50022–35 rail (15 mm deep) or fastens with four M4 screws, and measures 240 x 140 x 85 mm at 1.6 kg. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this ABB 07 KT 94 a genuine unit or a clone?
Autronexa verifies every controller against OEM datasheet markings and part-number cross-reference. The 07 KT 94 GJR5252100R0161 we supply is genuine ABB surplus or refurbished stock, not a grey-market copy.
What condition will the 07 KT 94 arrive in?
Units ship in refurbished condition by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you require surplus condition details for a specific unit.
How fast can Autronexa ship the 07 KT 94?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability — we confirm lead times before you commit.
Does the 07 KT 94 support CS31 system bus expansion?
Yes. The controller expands via the CS31 system bus to a maximum of 31 remote modules, supporting up to 992 digital inputs, 992 digital outputs, and 224 analog input and output channels.
Is the ABB 07 KT 94 still supported by ABB?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before ordering.
Related & compatible parts
ABB
AI801
Genuine surplus ABB AI801 analog input module — 8 channels, 12-bit, S800L mechanics. Verified condition, faster than OEM…
ABB
DO910-S
Genuine surplus ABB DO910-S: 4-channel intrinsically safe digital output for S900 I/O, ATEX Zone 1, verified and ready…
ABB
DP820
Genuine surplus ABB DP820 two-channel pulse counting module for incremental transmitters up to 1.5 MHz — verified condition,…
ABB
V18345-1010120001
Genuine surplus ABB TZIDC positioner, 4–20 mA two-wire, IP 65, single-acting fail-safe — verified condition, ready to ship.
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…