ABB AI950N
Input Module
Genuine surplus ABB AI950N temperature input module for S900 I/O — 4 isolated channels, Pt100/Pt1000/Ni100 and thermocouple support, verified and ready to source.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Article Number | 3KDE175523L9500 |
|---|---|
| Number of Channels | 4 |
| Input Types | Pt100, Pt1000, Ni100 (2-/3-/4-wire); thermocouples B, E, J, K, L, N, R, S, T, U, mV |
| Isolation | Channel-to-channel; input/bus and input/power |
| Ambient Temperature | -20 °C...60 °C |
| Relative Humidity | max. 93 % +/- 3 % at 40 °C |
| Corrosive Atmosphere | ISA-S71.04 G3 |
| Dimensions (W x D x H) | 20 mm x 104 mm x 104 mm |
| Weight | 0.13 kg |
Description
How do you keep temperature measurement accurate when a remote I/O station sits in a corrosive plant environment and spare modules are hard to find? The ABB AI950N temperature input module answers that with four electrically isolated channels, Pt100/Pt1000/Ni100 support in 2-, 3- and 4-wire technique, and thermocouple coverage from types B through U plus mV — a genuine surplus unit Autronexa verifies before it ships.
What This S900 I/O Module Does in Practice
The AI950N (article number 3KDE175523L9500) is the four-channel temperature input card for ABB’s S900 I/O type N system, the variant intended for installation in safe, non-hazardous areas. It reads resistance thermometers and thermocouples directly in the field, which is the point of the S900 architecture: the I/O station sits near the process, so marshalling and wiring costs drop compared with centralised cabinets. Each channel is isolated from the bus and from the power supply, and channel-to-channel isolation is included as well, so a fault on one loop does not drag neighbouring measurements with it. Short-circuit and break detection are built in, and cold junction compensation can be internal or external depending on how the thermocouple wiring is arranged. The module communicates upward through PROFIBUS DP. Integrated disconnection mechanisms allow replacement during operation, and hot-swap plus hot configuration in run are part of the feature set — practical when a channel fails on a live line.

Why Genuine Surplus Fits This Module
Temperature input cards are rarely kept in deep spares stock, yet a single failed channel can force a loop onto manual control. Autronexa supplies surplus and refurbished S900 components as genuine parts, verified against OEM datasheet markings and part-number cross-reference before dispatch. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. For a module with this channel count and isolation scheme, that verification matters more than the box it arrives in. Because surplus stock already exists in the channel, lead time is typically shorter than a factory order — confirm current availability with our team rather than assuming a shelf date.
Sourcing Checks Before You Order
Match the exact article number 3KDE175523L9500 and confirm you need the type N variant for a safe-area installation, not a hazardous-area S900 version. Confirm the sensor mix on your loops — resistance thermometers in 2-, 3- or 4-wire technique, or thermocouples with the compensation method your wiring uses. Ask for the condition grade in writing: surplus and refurbished units are not the same, and the difference affects how you plan commissioning. The module carries CE marking, RoHS compliance under DIRECTIVE/2011/65/EU (EN 50581:2012), and G3 coating for corrosive atmospheres rated ISA-S71.04 G3, with an ambient range of -20 °C…60 °C and relative humidity max. 93 % +/- 3 % at 40 °C. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this ABB AI950N a genuine module or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before dispatch. The AI950N carries article number 3KDE175523L9500, and we confirm that marking on the unit itself.
What condition will the AI950N arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — ask for the condition grade in writing before ordering.
How fast can you ship this temperature input module?
Lead time depends on current stock. Contact Autronexa for current lead time and availability; surplus stock in the channel is typically faster than a factory order.
Does the AI950N work with PROFIBUS DP control systems?
Yes. The S900 I/O system communicates with the control system level using the PROFIBUS DP standard, and this module is part of that system. Confirm your network configuration with your controls engineer.
Which sensors can the AI950N read?
It supports Pt100, Pt1000 and Ni100 resistance thermometers in 2-, 3- and 4-wire technique, plus thermocouple types B, E, J, K, L, N, R, S, T, U and mV, with internal or external cold junction compensation.
Related & compatible parts
ABB
CI862
Genuine surplus ABB CI862 CEX module connects up to 30 TRIO blocks per LAN, redundant-capable, for AC 800M…
ABB
AI825
Genuine surplus ABB AI825 analog input module — 4 isolated channels, 14-bit resolution, verified condition and clear lead…
ABB
DI524
Genuine surplus ABB DI524 S500 digital input module — 32 DI at 24VDC, verified condition and faster lead…
ABB
560PSU02
Genuine surplus ABB 560PSU02 RTU560 power supply — verified, tested, and ready to ship for sub-rack power.
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…