ABB CI862
Via the CI862 CEX module
Genuine surplus ABB CI862 CEX module connects up to 30 TRIO blocks per LAN, redundant-capable, for AC 800M controllers.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Article Number | 3BUA000037R1 |
|---|---|
| Communication Protocol | ABB's TRIO/Genius I/O |
| Master or Slave | Master |
| Max Units on CEX Bus | 4 |
| Max TRIO Blocks per LAN | 30 |
| Module Redundancy | Yes |
| Hot Swap | Yes |
| 24 V Consumption (typ.) | 190 mA |
| Operating Temperature | +5 to +55 °C (+41 to +131 °F) |
| Protection Class | IP20 according to EN60529, IEC 529 |
Description
When a TRIO/Genius I/O segment needs a native interface to an AC 800M controller, the ABB CI862 CEX module is the communication bridge that keeps channel data flowing. Maintenance and procurement teams choose genuine surplus or refurbished units of this module to restore I/O connectivity without waiting on OEM lead times, and Autronexa verifies each unit against OEM datasheet markings before it ships.
What the CI862 Does in an AC 800M Architecture
This unit is a master communication interface that integrates TRIO/Genius I/O as native AC 800M I/O. It manages channel data for the controller and handles I/O configuration and scanning for up to 30 TRIO blocks on a single LAN. An AC 800M can host up to four unit CEX modules, supporting a maximum of 1,000 TRIO/Genius I/O points. The module provides one direct TRIO LAN connection plus a port for the Hand Held Monitor. Module redundancy is supported, and the unit is hot-swappable — a practical advantage when a segment must be serviced without dropping the controller. Connectors include Phoenix (4-pin) and DB9 male and female.

Sourcing This Module Without the OEM Wait
Life cycle status for This unit is Classic, which means new-from-OEM supply can be slow or unavailable depending on channel. That is exactly where genuine surplus and refurbished stock earns its place. Autronexa sources This unit as a verified genuine unit, tests it against OEM datasheet specifications, and functionally verifies it before dispatch. You get a module that matches the original article number 3BUA000037R1, with clear lead times rather than an open-ended factory backlog. For plants running mixed AC 800M and TRIO/Genius installations, keeping a verified spare on the shelf is the difference between a planned swap and an extended outage. Surplus and refurbished, ready to ship — with the condition stated up front.

Matching This unit to Your Existing Installation
Before ordering, confirm the controller side and the I/O side. On the controller side, verify your AC 800M CEX bus has capacity — the maximum is four unit modules, and each supports one TRIO LAN. On the I/O side, count your TRIO blocks: a single module handles up to 30 per LAN. Decide whether you need module redundancy, since This unit can be set redundant, and confirm the Hand Held Monitor port is required for your maintenance routine. Check the environmental envelope: operating temperature is +5 to +55 °C, storage is -40 to +70 °C, and relative humidity is 5 to 95 % non-condensing. The module is rated IP20 per EN60529 and IEC 529, carries CE marking, and complies with WEEE DIRECTIVE/2012/19/EU. Typical 24 V consumption is 190 mA. Dimensions are 59 mm wide, 185 mm high, and 127.5 mm deep, with a weight of 700 g including base. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this ABB CI862 a genuine module or a clone?
Autronexa verifies each CI862 against OEM datasheet markings and part-number cross-reference, including article number 3BUA000037R1, before it is listed as genuine surplus or refurbished stock.
What condition will the CI862 arrive in?
Units are supplied in the site default condition, Refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a specific condition grade confirmed before purchase.
How fast can Autronexa ship the CI862?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; surplus and refurbished units are ready to ship when in stock.
Can the CI862 connect to an AC 800M controller with redundant LANs?
Yes. The CI862 supports module redundancy and can be set redundant. An AC 800M can host up to four CI862 CEX modules, configured as up to four single LANs or four redundant LANs, with a maximum of 1,000 TRIO/Genius I/O points.
Is the CI862 still supported by ABB?
The lifecycle status listed for this module is Classic. Contact Autronexa to verify current OEM support status and availability before ordering.
Related & compatible parts
ABB
PM862K01
Genuine surplus ABB PM862K01 CPU board for AC 800M — verified condition, tested against OEM datasheet specs, ready…
ABB
PM858K01
Genuine surplus ABB PM858K01 CPU board for AC 800M — verified condition, practical sourcing support, and faster availability…
ABB
CI854A
Genuine surplus ABB CI854A PROFIBUS-DP/V1 master module with 2 channels, line and master redundancy, hot swap — verified…
ABB
DI828
Genuine surplus ABB DI828 digital input module — 16 isolated channels, 120V AC/DC, verified and ready to ship.
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…