ABB CI532V02
Communication_Module
Genuine ABB CI532V02 MODBUS interface submodule for Advant controllers — verified surplus stock with two RCOM/RCOM+ channels.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Product ID | 3BSE003827R1 |
|---|---|
| ABB Type Designation | CI532V02 |
| Catalog Description | MODBUS Interface, 2 ch |
| Long Description | RCOM/RCOM+ communication interface submodule for Advant controllers |
| Product Net Depth / Length | 234 mm |
| Product Net Height | 22.5 mm |
| Product Net Width | 108 mm |
| Product Net Weight | 0.155 kg |
| Customs Tariff Number | 85389091 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
Description
When a legacy Advant controller loses its MODBUS link, every hour of downtime erodes production. The ABB CI532V02 is a genuine RCOM/RCOM+ communication interface submodule that restores two independent channels to your process control system. Sourcing a verified surplus unit beats waiting on OEM lead times.
What This Submodule Actually Does in an Advant System
The CI532V02 is not a standalone gateway — it is a submodule that slots into an Advant controller rack to provide MODBUS connectivity. Each interface carries two channels, so a single submodule can serve two separate serial links. The catalog description confirms it as a “MODBUS Interface, 2 ch” with the ABB type designation unit. Its compact footprint — 234 mm deep, 108 mm wide, 22.5 mm high, and 0.155 kg — means it fits the same rack space as the original module without adapter hardware. Because it is a submodule, it depends on the host controller for power and backplane communication; no separate supply wiring is needed. That design keeps spares simple: you stock one submodule and swap it when a channel fails, rather than replacing an entire communication card.

Why Surplus Makes Sense for This Advant Part
ABB has long since moved its process control portfolio forward, and Advant Master systems remain in service across many plants. This unit is exactly the kind of part where surplus and refurbished stock outperforms the OEM channel. Autronexa sources genuine units, verifies them against OEM datasheet markings, and functionally tests each submodule before it ships. You avoid the long lead times that come with ordering a legacy submodule through official channels, and you get a part that matches the original 3BSE003827R1 product ID. Note that this part is exempted from the scope of 2011/65/EU (RoHS) as provided in Article 2(4)(c), (e), (f) and (j) therein — a detail worth confirming with your compliance team before purchase. For maintenance managers keeping an Advant system running, a verified surplus submodule is a practical bridge while a long-term migration plan takes shape.

Sourcing Checklist Before You Order
Not every unit on the secondary market is what it claims to be. Start by confirming the product ID 3BSE003827R1 matches your controller’s documentation. Ask whether the unit is surplus (pulled from service) or refurbished (tested and restored), and request the test record. Check that both channels are functional — a submodule with one dead channel still fits the rack but defeats the purpose. Confirm the host controller model and firmware compatibility with your supplier, since Advant systems vary by revision. Autronexa provides verified condition notes and current availability on request, so you can match the submodule to your rack before committing. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this CI532V02 a genuine ABB module or a clone?
Autronexa verifies each unit against OEM datasheet markings and the product ID 3BSE003827R1. We do not source grey-market copies.
What condition will the CI532V02 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — confirm the condition you need when you contact us.
How fast can you ship the CI532V02?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability.
Does the CI532V02 work with any Advant controller?
It is an RCOM/RCOM+ communication interface submodule for Advant controllers. Confirm your specific controller model and revision with our sourcing team before ordering.
Is the CI532V02 still supported by ABB?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and availability for this legacy submodule.
Related & compatible parts
ABB
TU841
Genuine surplus ABB TU841 termination unit for non-redundant I/O — verified condition, practical lead times, sourcing support from…
ABB
SB822
Genuine surplus ABB SB822 battery unit for AC 800M — verified condition, DIN-rail mount, ready to ship from…
ABB
07 KT 98
Genuine surplus ABB 07 KT 98 Controller 31 basic unit — verified condition, CS31 field bus, 24 DI/16…
ABB
PM858K02
Genuine surplus ABB PM858K02 CPU board kit with TP830 baseplates, TB807 terminators and backup batteries — verified condition,…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…