| Product Type | Analog input 560AIR02 |
|---|---|
| Product Line | RTU560 |
| Input Channels | 8 differential inputs |
| AD Converter Resolution | 16 bit |
| Configurable Measuring Ranges | ±2 mA; ±5 mA; ±10 mA; ±20 mA; ±40 mA |
| Signal Types | Analog measured values (AMI); measured floating point information (MFI) |
| Conversion Time per Channel (50/60 Hz) | 54 ms |
| Scan Cycle Time (50/60 Hz) | 486 ms |
| Conversion Time per Channel (16.7 Hz) | 155 ms |
| Scan Cycle Time (16.7 Hz) | 1395 ms |
Description
When analog measurement channels fail in a remote terminal unit, every hour of downtime adds cost. The ABB RTU560 560AIR02 analog input module restores eight channels of 16-bit measurement to RTU560 systems, and genuine surplus stock from Autronexa gives you a verified replacement without the OEM lead-time premium.
What the 560AIR02 Does in an unit System
The 560AIR02 is an analog input module from ABB’s unit product line. It records up to eight analog measured values and processes analog measured values (AMI) and measured floating point information (MFI). The module performs basic signal checks and cyclic processing locally, transmitting relevant changes as events over the RTU I/O bus. That local processing unburdens the communication unit, which matters when a single CMU serves many I/O modules: less traffic per module means more headroom for other channels, and less risk of scan-cycle bottlenecks that force hardware upgrades. The eight differential inputs are galvanically connected to the power supply, and a protection circuit guards against static and dynamic over-voltages. A low-pass filter suppresses unwanted frequency components, reducing measurement noise that would otherwise trigger false events and unnecessary maintenance callouts.

Technical Specs and Their Cost Implications
The AD converter resolution is 16 bit. That internal resolution lets the module scan all measuring ranges with the same resolution, so you configure the range to the sensor rather than buying a different module per range. Configurable measuring ranges include ±2 mA, ±5 mA, ±10 mA, ±20 mA, and ±40 mA; other input ranges and live zero values are generated by conversion on the communication unit, so one module type covers a wider span of field signals and reduces spares inventory. Single-ended or differential input values resolve by up to 4096 steps (12 bit plus sign) for 100% measurement amplitude. An additional measurement channel performs automatic zero calibration, compensating long-term drift of components — fewer recalibration interventions over the service life. At 50 Hz and 60 Hz line frequencies, conversion time per channel is 54 ms and scan cycle time is 486 ms for all channels; at 16.7 Hz, conversion time is 155 ms and scan cycle is 1395 ms. Matching the scan cycle to the line frequency increases line-frequency interference suppression on DC input signals, which protects measurement accuracy without external filtering hardware.

Surplus Advantage: Verified Genuine Parts Without the OEM Wait
Autronexa supplies this module as genuine surplus and refurbished stock, tested against OEM datasheet specifications and functionally verified by our sourcing team. For a mature product line like unit, OEM lead times can stretch while list prices stay high; a verified surplus unit keeps spares budgets predictable and gets a failed channel back online sooner. Because the module handles range configuration and calibration internally, a verified replacement drops into the existing unit rack without extra signal-conditioning purchases. Confirm the exact revision and condition grade with our team before ordering — we document what we ship. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this ABB RTU560 560AIR02 a genuine ABB module or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. The 560AIR02 we ship is genuine ABB surplus or refurbished hardware, not a grey-market copy.
What condition will the 560AIR02 arrive in?
Our default condition is Refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a specific condition grade or surplus-only unit.
How fast can Autronexa ship the 560AIR02?
Lead time depends on current verified stock. Contact Autronexa with your part number for current availability and a confirmed ship date — surplus and refurbished units are ready to ship once verified.
Does the 560AIR02 support all five measuring ranges in one module?
Yes. The ±2 mA, ±5 mA, ±10 mA, ±20 mA, and ±40 mA ranges are configurable, and other input ranges and live zero values are generated by conversion on the communication unit. Range and line frequency are set with the RTUtil500 configuration tool.
Is the ABB RTU560 560AIR02 still supported by ABB?
Lifecycle status is not stated in our current data. Contact Autronexa to verify OEM support status and current availability before ordering.
Related & compatible parts
ABB
V18345-1010121001
Genuine surplus ABB TZIDC positioner, 4–20 mA two-wire, IP 65 / NEMA 4X, single acting fail safe. Verified…
ABB
TU831V1
Genuine surplus ABB TU831V1 Extended MTU: 8 isolated channels, 250V, 3A per channel. Verified condition, ready to ship.
ABB
AI910N
Genuine surplus ABB AI910N analog input module for S900 I/O — 4 channels, 4...20 mA, G3 coating, verified…
ABB
FENA-11
Genuine surplus ABB FENA-11 Ethernet adapter for ACS880 drives — verified condition, faster than OEM lead times.
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…