ABB TB842
ModuleBus Optical Port is a communication interface between the CI801 or
Genuine surplus ABB TB842 ModuleBus optical port — verified, tested, and ready to ship for CI801/CI840 I/O clusters.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Article Number | 3BSE022464R1 |
|---|---|
| Communication Protocol | Modulebus |
| Connector Type | Agilent Versatile Link |
| Data Rate | Max. 10 Mbit/s |
| Wavelength | 650 nm |
| Power Consumption | 24 V, typ. 20 mA |
| Operating Temperature | 0 to +55 °C |
| Ingress Protection | IP20 |
| Dimensions (W×H×D) | 17.6 × 56.7 × 42.3 mm |
| Weight | 90 g |
Description
When a ModuleBus link drops out, the whole I/O cluster goes dark and maintenance teams need a verified replacement fast. The ABB TB842 ModuleBus optical port (3BSE022464R1) is the fiber-optic interface that keeps CI801 or CI840/CI840A controllers talking to TB820/TB820V2/TB840/TB840A modems. Autronexa supplies genuine surplus and refurbished units, each functionally verified before dispatch.
What This Optical Port Does in Your System
The TB842 sits between the communication interface module and the optical ModuleBus. It provides one fiber-optic port with a transmit and receive connection rated for up to 10 Mbit/s at 650 nm wavelength. The module uses Agilent (formerly Hewlett-Packard) Versatile Link connectors, so it accepts both plastic and HCS (Hard Clad Silica) fiber. In a simplex configuration, nodes connect in a ring; in a duplex setup, they connect in a row. The unit supports line and module redundancy plus hot swap, which matters when you need to replace a port without shutting down the cluster. It draws typically 20 mA at 24 V and dissipates 0.5 W. Mounting is vertical or horizontal, and the IP20 housing measures 17.6 mm wide, 56.7 mm high, and 42.3 mm deep at 90 g. Operating temperature is 0 to +55 °C, with approvals issued for +5 to +55 °C; for vertical mounting, the maximum ambient is 40 °C.

Why Genuine Surplus Makes Sense for This Module
ABB ModuleBus optical ports are often replaced as complete units rather than repaired in the field, so verified surplus stock gives maintenance teams a practical alternative to waiting on OEM lead times. Every unit we offer is tested against the OEM datasheet specifications and functionally verified by our sourcing team. You get the same connector type and optical performance without paying a brand-new list price. Because the module supports hot swap and redundancy, a spare on the shelf can cut the window between fault detection and restoration. Autronexa specialises in genuine surplus and refurbished automation components across ABB, Allen-Bradley, Siemens, Schneider and other major platforms. If you are maintaining an older I/O cluster, contact us with your part number for verified condition and current availability.

Sourcing and Compatibility Checks Before You Order
Before committing to a replacement, confirm the exact article number 3BSE022464R1 and check how the port connects in your configuration. For a single I/O setup, This unit links to CI801 via TB806, or to CI840/CI840A via TU847 and TB806. For redundant I/O, it connects via TU846 and TB846. Make sure every node on the ModuleBus uses the same transmitter/receiver type, because mixed optical types will not communicate reliably. Also verify the mounting orientation against your ambient temperature: vertical mounting reduces the maximum ambient to 40 °C. The unit carries CE marking, EN 61010 and UL 61010 electrical safety approvals, and is rated for ATEX Zone 2 and cULus Hazardous Location Class 1 Zone 2. Marine certificates include ABS, BV, DNV-GL and LR. Autronexa can help you cross-check revision details and accessory compatibility so the part you receive matches your system. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine ABB TB842, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished ABB modules, not grey-market copies.
What condition will the TB842 arrive in?
Our default condition is refurbished: each unit is tested against OEM specifications and functionally verified by our sourcing team before dispatch.
How fast can you ship the TB842?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability.
Does the TB842 work with both CI801 and CI840/CI840A controllers?
Yes. The TB842 connects to CI801 via TB806, and to CI840/CI840A via TU847 and TB806 for single I/O, or via TU846 and TB846 for redundant I/O.
Can I use plastic and HCS fiber with this module?
The TB842 accepts both plastic and HCS (Hard Clad Silica) fiber with Agilent Versatile Link connectors. Every node on the ModuleBus must use the same transmitter/receiver type.
Related & compatible parts
ABB
INNPM22
Genuine surplus ABB INNPM22 network processor for Symphony Infi 90 — verified condition and faster lead time than…
ABB
CI867K01
Genuine surplus ABB CI867K01 Modbus TCP interface with TP867 baseplate — verified condition, faster than OEM lead times.
ABB
CI868K01
Genuine surplus ABB CI868K01 IEC 61850 interface module with TP867 baseplate — verified condition, ready to ship from…
ABB
DI821
Genuine surplus ABB DI821 digital input module for S800 I/O — 8 isolated channels, 230 V a.c./220 V…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…