ABB TU847
Module termination unit
Genuine surplus ABB TU847 termination unit for redundant CI840/CI840A — verified condition, faster than OEM lead time.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Article number | 3BSE022462R1 |
|---|---|
| Communication protocol | PROFIBUS DP-V1 |
| Power input | 24 V d.c. (19.2 - 30 V) |
| Module redundancy | Yes |
| Hot Swap | No |
| Connector | PROFIBUS DSUB9; service ports RJ45 |
| Acceptable wire sizes | 0.25 - 2.5mm², 24 - 14 AWG |
| Operating temperature | 0 to +55 °C (+32 to +131 °F) |
| Ingress protection | IP20 according to IEC 529 |
| Dimensions (W x H x D) | 124 mm x 186 mm x 47 mm |
Description
The ABB TU847 module termination unit connects power, ModuleBus, and two CI840/CI840A interfaces in redundant field communication setups. Engineers maintaining PROFIBUS DP-V1 architectures need this exact termination base when a channel fails, and sourcing a genuine surplus or refurbished unit keeps the line running without waiting on OEM lead times.
What This Termination Unit Does in a Redundant CI840 Pair
The TU847 is a passive base that carries the wiring for two CI840/CI840A field communication interfaces. It provides connections for the 24 V d.c. power supply (19.2–30 V), the electrical ModuleBus, and two service ports on RJ45 connectors. Two rotary switches set the station address from 0 to 99, so commissioning stays local and does not depend on software tools.
Mechanical keying is a practical detail worth noting. Four keys, two per position, each with six settings, give 36 different configurations. That prevents inserting the wrong module type into the base. The unit latches to DIN rail for locking and grounding, and it mounts vertically or horizontally. Remember that TU846/unit needs clearance to the left for removal, and it cannot be replaced with power applied.

Why Genuine Surplus Fits This ABB Base
Redundant CI840 configurations are usually part of a running process, and a failed termination base stops both channels. OEM lead times on legacy ABB modules can stretch, while a verified surplus unit is often available sooner. Autronexa stocks genuine parts, verified against OEM datasheet markings and part-number cross-reference, so This unit you receive matches the 3BSE022462R1 article number and the connector layout described here.
Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. That means the 24 V input range, the RJ45 service ports, and the mechanical key positions are checked before shipping. For a passive base like this, condition matters more than firmware version, and surplus stock often preserves the original keying configuration.

Sourcing Checks Before You Order
Confirm the exact article number and whether your installation uses the standard unit or the G3-compliant unitZ variant. Check that the CI840/CI840A modules you plan to seat match the mechanical key positions, since the 36-combination keying is set at the factory. Verify wire sizes against the 0.25–2.5 mm² range and the recommended torque of 0.5–0.6 Nm before terminating.
Autronexa can confirm condition, keying, and current availability from stock. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine ABB TU847, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference. The TU847 carries article number 3BSE022462R1, and we confirm the connector layout and keying before shipping.
What condition will the TU847 arrive in?
Our default condition is Refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available when stock allows.
How fast can you ship the TU847?
Lead time depends on current stock. Contact Autronexa for current lead time and availability; surplus and refurbished units are often ready to ship faster than OEM backorders.
Does the TU847 work with CI840 and CI840A modules?
Yes. The TU847 is designed for redundant configuration of the CI840/CI840A field communication interface, with two PROFIBUS connections and two service tool connections on RJ45 ports.
Is the TU847 still supported by ABB?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before ordering.
Related & compatible parts
ABB
V18345-2010420001
Genuine surplus ABB TZIDC positioner, 4–20 mA two-wire, IP 65, double acting fail safe — verified condition and…
ABB
PM858K01
Genuine surplus ABB PM858K01 CPU board for AC 800M — verified condition, practical sourcing support, and faster availability…
ABB
DI820
Genuine surplus ABB DI820 digital input module — 8 isolated channels, 120 V a.c./110 V d.c., verified condition…
ABB
V18345-2010421001
Genuine surplus ABB TZIDC positioner, double-acting fail-safe, 4–20 mA, IP 65. Verified condition and sourcing support from Autronexa.
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…