Schneider Electric Cables & Connectors
Schneider Electric ABE7R16S210
Electromechanical output relay sub-base
Genuine surplus Schneider Electric ABE7R16S210 relay sub-base — 16 channels, 10 A commons, DIN-rail mount. Verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Range of product | Modicon ABE7 |
|---|---|
| Number of channels | 16 |
| Rated supply voltage | 24 V DC for PLC end |
| Maximum current per output common | 10 A |
| Current per channel | 5 A for preactuator end |
| Contacts type and composition | 1 NO for preactuator end |
| Maximum switching voltage | 250 V AC 50/60 Hz; 30 V DC conforming to IEC 60947-5-1 |
| Fixing mode | By clips (35 mm symmetrical DIN rail); by screws (solid plate with fixing kit) |
| Width | 206 mm |
| Net weight | 0.405 kg |
Description
When a relay sub-base fails on a running Modicon ABE7 rack, every hour of downtime compounds. The Schneider Electric ABE7R16S210 is a 16-channel electromechanical output relay sub-base that restores volt-free switching between your PLC and preactuator loads. Autronexa supplies genuine surplus and refurbished units, verified against OEM datasheet markings, so you get a practical replacement without the OEM lead-time wait.
What This Sub-Base Does in Your Panel
The ABE7R16S210 sits between the PLC output card and field devices, providing 16 independent 1 NO relay contacts. Each channel carries up to 5 A at the preactuator end, while each output common handles a maximum of 10 A. The volt-free contact arrangement means you can switch 250 V AC 50/60 Hz or 30 V DC circuits, conforming to IEC 60947-5-1, without tying the PLC supply to the load. The unit clips onto 35 mm symmetrical DIN rail or mounts by screws with a fixing kit. Removable terminal blocks simplify wire changes during service. With a 206 mm width and 0.405 kg net weight, it fits standard panel layouts.

Reliability and Service Notes
From a maintenance standpoint, This unit is built for long service intervals. Mechanical durability is rated at 20,000,000 cycles, and electrical durability reaches 500,000 cycles at 1500 mA and 230 V AC-12. Coil energisation and NO closing take no more than 10 ms; de-energisation and NO opening complete in 5 ms or less, which helps when sequencing fast outputs. The IP2X protection and -5…60 °C operating range suit typical cabinet environments. For inspection, check terminal torque at 0.6 N.m with a flat Ø 3.5 mm screwdriver, and verify that the removable blocks are fully seated after any wiring work. Follow the manufacturer safety manual for all maintenance.

Surplus Advantage: Practical Lead Times
Genuine surplus and refurbished unit units make sense when an OEM replacement quote stretches weeks and the line needs to run. Autronexa sources these sub-bases from decommissioned panels and verified refurbishment channels. Each unit is inspected for contact wear, coil condition, and terminal integrity, then tested against OEM datasheet specifications and functionally verified by our sourcing team. You get a genuine part with clear condition notes and current availability, not a grey-market unknown. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this ABE7R16S210 a genuine Schneider Electric unit or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished Schneider Electric components, not clones or copies.
What condition will the ABE7R16S210 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available; contact Autronexa for current condition notes on specific stock.
How fast can you ship the ABE7R16S210?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; we confirm lead time before order placement.
Does this sub-base work with Modicon ABE7 racks?
Yes, the ABE7R16S210 is part of the Modicon ABE7 range and mounts on 35 mm symmetrical DIN rail or by screws with a fixing kit. Confirm your rack and PLC output compatibility with Autronexa before ordering.
Related & compatible parts
Schneider Electric
140CPU42401C
Genuine surplus Schneider Electric 140CPU42401C CPU module — verified, tested, and ready to ship for Modicon Quantum systems.
Schneider Electric
BMXXBE1000
Genuine surplus Schneider Electric BMXXBE1000 X-bus rack expansion module — verified condition, practical lead times, and sourcing support…
Schneider Electric
140NOE25100C
Genuine surplus Schneider Electric 140NOE25100C Ethernet module — fiber-optic support, one channel, verified condition and clear lead times.
Schneider Electric
490NAC0201
Genuine surplus 490NAC0201 fiber optic singlemode adapter for Modicon M580 HSBY CPUs — verified condition, ready to ship.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
