Schneider Electric Drives & Inverters
Schneider Electric ATV610D18N4
Variable speed drive
Genuine surplus Schneider ATV610D18N4 drive: 18.5 kW, 380...460 V, C3 EMC filter, Modbus. Verified condition and clear lead times from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated motor power | 18.5 kW (25 HP) normal duty; 15 kW (20 HP) heavy duty |
|---|---|
| Supply voltage | 380...460 V AC, 50/60 Hz, three-phase |
| Maximum continuous output current | 39.2 A (normal duty) |
| Maximum transient current (60 s) | 43.1 A (normal duty) |
| Integrated EMC filter | Category C3 |
| Integrated HMI | Plain text display terminal VW3A1113 (2 lines, white backlit LCD, RJ45) |
| Built-in communication | 2 RJ45 ports; Modbus RTU |
| Dimensions (H×W×D) | 495 × 211 × 232 mm |
| Weight | 13.5 kg (29.8 lb), without packaging |
| Protection rating | IP20 (IP40 on the top of the product) |
Description
When a pump or fan drive drops out on a running process, every hour of lost throughput adds pressure to maintenance and procurement alike. The Schneider Electric ATV610D18N4 is an Easy Altivar 610 variable speed drive rated 18.5 kW (25 HP) normal duty on a 380…460 V three-phase supply, and Autronexa supplies it as genuine surplus or professionally refurbished stock with verified condition and clear lead times.
What This Drive Does in a Pump or Fan System
The Easy Altivar 610 family is built around variable-torque pump and fan duty, and this variant carries the ratings that matter for that role: 18.5 kW (25 HP) normal duty, 39.2 A maximum continuous output current, and 43.1 A maximum transient current for 60 s. The quadratic U/f Vc (UFQ) control mode in the programming manual suits centrifugal loads, while the integrated C3 EMC filter removes a separate filter from the panel build. A plain text display terminal VW3A1113 with a two-line white backlit LCD and RJ45 connection handles local setup. The unit ships in frame size 3 at 495 × 211 × 232 mm and 13.5 kg, with fan cooling and a fan that is field-replaceable in under 5 minutes without special tools.

Technical Specs That Shape the Installation
Three values drive most panel decisions. First, the 37.2 A maximum input current at 380 V and 33.5 A at 460 V, with 26.7 kVA apparent power at 460 V, sets upstream protection and cable sizing. Second, the 474 W total power dissipation at nominal current in an enclosed cabinet governs enclosure ventilation and air-conditioning load. Third, the 100 m shielded or 200 m unshielded maximum motor cable length without a dv/dt output filter, with a filter recommended above 50 m, decides whether an output filter belongs in the bill of materials. I/O covers 3 analog inputs, 6 digital inputs at 24 V DC (2 programmable as pulse inputs), 2 analog outputs, and 3 relay outputs, with Slot A free for an Extended I/O module VW3A3203, Extended relay module VW3A3204, or PROFIBUS DP V1 module VW3A3607. Built-in communication is Modbus RTU over two RJ45 ports.

Why Genuine Surplus Fits This Model
The Easy Altivar 610 line remains active, so a surplus or refurbished unit is a practical alternative when an OEM lead time does not match a shutdown window. Autronexa sources genuine units and verifies them against OEM datasheet markings and part-number cross-reference; refurbished stock is tested against OEM datasheet specifications and functionally verified by our sourcing team. Because the drive is fan cooled with a field-replaceable fan, condition checks focus on the cooling path, terminal torque at 2.5 N·m for frames 1–3, and the conformal-coated cards. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this ATV610D18N4 a genuine Schneider Electric drive or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. The drive is supplied as genuine surplus or professionally refurbished, not as a grey-market copy.
What condition will the drive arrive in?
The site default condition is Refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available; confirm the exact condition you need when you request a quote.
How fast can Autronexa ship the ATV610D18N4?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; surplus and refurbished units are ready to ship once confirmed.
Does this drive support Modbus and the VW3A3607 PROFIBUS module?
Yes. Built-in communication is Modbus RTU over two RJ45 ports, and Slot A accepts the PROFIBUS DP V1 module VW3A3607 with Profidrive and CiA402 profiles, per the published data.
Is the Easy Altivar 610 line still supported by Schneider Electric?
The Easy Altivar 610 product line shows active official product pages as of 2026-10. Verify current lifecycle status and availability with Autronexa before ordering.
Related & compatible parts
Schneider Electric
140X816
Genuine surplus Schneider 140X816 floating point adapter for Modbus Plus — verified condition, faster than OEM lead time.
Schneider Electric
140CPU65160C
Genuine surplus Schneider Electric 140CPU65160C Unity Processor — verified condition, Modicon Quantum series, ready to ship.
Schneider Electric
ATV610U30N4
Genuine surplus Schneider Electric ATV610U30N4 drive: 3 kW normal duty, 380...460 V three-phase, C3 EMC filter, tested and…
Schneider Electric
TSXP571634
Genuine surplus Schneider Electric TSXP571634 Unity Processor — verified, refurbished, with 512 discrete and 24 analogue I/O capacity.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…