Schneider Electric Drives & Inverters
Schneider Electric ATV610D11N4Z
Variable speed drive
Genuine surplus Schneider ATV610D11N4Z, 11 kW drive with C3 EMC filter — verified condition, ready to ship from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated motor power | 11 kW (15 HP) normal duty; 7.5 kW (10 HP) heavy duty |
|---|---|
| Supply voltage | 380...460 V AC, 50/60 Hz, three-phase |
| Maximum continuous output current | 23.5 A (normal duty) |
| Integrated EMC filter | Category C3 |
| Built-in communication | 2 RJ45 ports; Modbus RTU |
| Digital inputs | 6, 24 V DC (2 programmable as pulse inputs) |
| Operating temperature | -15...+45 °C without derating |
| Protection rating | IP20 (IP40 on top) |
| Dimensions (H×W×D) | 360 × 171 × 233 mm |
| Weight | 7.54 kg (16.62 lb), without packaging |
Description
The ATV610D11N4Z is a Schneider Electric variable speed drive from the Easy Altivar 610 series, rated 11 kW (15 HP) normal duty for three-phase pumps and fans. Maintenance and procurement teams choose genuine surplus or refurbished units of this model to avoid OEM lead times without risking clone hardware — Autronexa verifies each unit against OEM datasheet markings before it ships.
What This Drive Does in a Pump or Fan System
This frame size 2 unit runs three-phase asynchronous and synchronous motors in open loop, with U/f quadratic control (UFQ) suited to variable-torque fan and pump loads. The integrated C3 EMC filter simplifies panel build, and the built-in DC choke reduces input current harmonics. Two RJ45 ports separate the Modbus field network from the HMI multidrop link, so a VW3A1113 keypad can be added as an accessory without disturbing the control network. Slot A accepts either the VW3A3203 extended I/O module or the VW3A3204 extended relay module, and a PROFIBUS DP V1 module (VW3A3607) fits the same slot. Six 24 V DC digital inputs, three analog inputs and two analog outputs cover most pump and fan control schemes without extra hardware.

Key Ratings at a Glance
At 380…460 V three-phase, the drive delivers 23.5 A continuous normal duty with 25.9 A transient for 60 s. Heavy duty rating is 7.5 kW at 16.5 A continuous. The fan is field-replaceable in under five minutes without special tools, which matters on rooftop air-handling units where access is tight. Operating range is -15…+45 °C without derating, extending to +60 °C with power derating. The IP20 enclosure (IP40 on top) and conformal-coated boards suit dusty plant rooms, and the 360 × 171 × 233 mm footprint keeps cabinet space predictable.

Surplus and Refurbished: A Practical Alternative
Schneider’s Easy Altivar 610 line remains active, but OEM lead times on individual ratings still stretch maintenance schedules. A verified surplus or refurbished unit of this model gives you the same Modbus RTU connectivity and C3 filtering without waiting on a factory allocation. Autronexa tests refurbished drives against OEM datasheet specifications and functionally verifies them before dispatch; surplus units are inspected for physical and electrical condition. For a pump station or AHU that is already down, that difference in lead time is the whole argument. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this ATV610D11N4Z a genuine Schneider Electric drive or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before listing. The N4Z suffix confirms the no-keypad configuration, and we check that against the nameplate.
What condition will the drive arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — confirm the condition you need when you request a quote.
How fast can Autronexa ship this model?
Contact Autronexa with your part number for verified condition and current availability. Lead time depends on stock at the time of order; we confirm it before you commit.
Does the drive include a keypad?
No. The N4Z version ships without the plain text display terminal. A VW3A1113 keypad connects via the RJ45 HMI port as a separate accessory.
Is the Easy Altivar 610 line still supported by Schneider Electric?
Official product pages were active as of October 2026. Contact Autronexa to verify OEM support status for this specific rating before ordering.
Related & compatible parts
Schneider Electric
140CPU21304C
Genuine surplus Schneider 140CPU21304C Modicon Quantum CPU — conformal coated, 768 KB RAM, verified and ready to ship.
Schneider Electric
LC1G1504KUEN
Genuine surplus Schneider Electric LC1G1504KUEN contactor, 4-pole, 275 A, 100/250 V ac/dc coil — verified condition and ready…
Schneider Electric
ATV320U07N4C
Genuine surplus Schneider ATV320U07N4C drive — 0.75 kW, 380–500 V three-phase, C2 EMC filter, verified and ready to…
Schneider Electric
TSXMRP064P
Genuine surplus Schneider TSXMRP064P flash memory module for TSX Micro PLCs — 64 KB RAM, 16-bit addressing, battery-backed.…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…