Schneider Electric Circuit Protection
Schneider Electric LC1G1504KUEN
Contactor
Genuine surplus Schneider Electric LC1G1504KUEN contactor, 4-pole, 275 A, 100/250 V ac/dc coil — verified condition and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Coil Voltage | 100/250 V ac/dc |
|---|---|
| Number of Poles | 4 |
| Contact Current | 275 A |
| Contact Voltage | 1000 V |
| Normal State Configuration | 1 NO/1 NC |
| Operating Temperature Range | -25°C to 60°C |
| Width | 140 mm |
| Depth | 193 mm |
| Length | 193 mm |
| Net Weight | 4.4 kg |
Description
When a high-power contactor fails on a running line, every hour of downtime adds cost. The Schneider Electric LC1G1504KUEN is a TeSys Giga 4-pole contactor rated 275 A at 1000 V AC-1, with a 100/250 V ac/dc coil — a genuine surplus unit verified by Autronexa for buyers who need dependable switching without OEM lead times.
What This TeSys Giga Contactor Delivers
The LC1G1504KUEN sits in Schneider’s TeSys Giga range, built for power switching in demanding industrial circuits. Its four normally-open poles handle a rated operational current of 275 A at up to 1000 V AC-1, or 150 A at 440 V AC-3 for motor loads. The wide-range coil accepts 100 to 250 V AC or DC, so one unit covers multiple control voltages — useful when standardising spares across a plant. A built-in bidirectional peak-limiting coil keeps inrush power to 540 VA AC or 380 W DC, while hold-in consumption drops to 12.4 VA AC or 7.8 W DC. Mechanical durability is rated at 8 million cycles, and the front face carries IP2X protection with shrouds. The contactor mounts on a plate and uses bar connections for the power circuit (25 x 6 mm busbar) plus push-in terminals for control wiring.

Why Genuine Surplus Makes Sense Here
A 275 A frame contactor is not a commodity item — OEM lead times on high-power TeSys Giga units can stretch, and plant engineers need a verified replacement, not a lookalike. Autronexa supplies genuine surplus and refurbished automation components, and each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team. You get the real Schneider coil technology, the correct 4 NO pole configuration, and the original terminal layout — without paying full list price or waiting on a factory allocation. For maintenance teams holding critical spares, that combination of authenticity and availability is the practical choice.

Sourcing Checklist Before You Order
Confirm the coil voltage your control circuit actually provides — this unit’s 100 to 250 V ac/dc range is broad, but the operational limits (0.8 Uc min to 1.1 Uc max at under 60 °C) matter for reliable pickup and drop-out. Check that your panel accepts the 140 mm width and 193 mm depth, and that power lugs suit the 25 x 6 mm busbar or 185 mm² ring terminals. Ask for the condition grade: Autronexa ships refurbished units by default, verified against the datasheet. Review the auxiliary contact arrangement — 1 NO plus 1 NC — against your control scheme. Finally, request the test record and current lead time. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this LC1G1504KUEN a genuine Schneider Electric contactor or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. This is a genuine Schneider Electric TeSys Giga contactor, sourced as surplus or professionally refurbished — not a grey-market copy.
What condition will the contactor arrive in?
Our default condition is refurbished: the unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch. Ask Autronexa for the specific condition grade and test record on the unit reserved for you.
How fast can Autronexa ship the LC1G1504KUEN?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability — we confirm dispatch dates before you commit.
Does the 100/250 V ac/dc coil work with my existing control circuit?
The coil accepts 100 to 250 V AC or DC, with operational limits of 0.8 Uc min to 1.1 Uc max at under 60 °C. Confirm your control voltage falls inside that band and check drop-out behaviour (0.1 Uc max to 0.45 Uc min) against your scheme.
Is the LC1G1504KUEN still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and availability before ordering.
Related & compatible parts
Schneider Electric
BMXXBC050K
Genuine surplus Schneider Electric BMXXBC050K X-bus expansion cable, 5.0 m, 9-pin SUB-D — verified condition, faster than OEM…
Schneider Electric
TSXCTZ2A
Genuine surplus Schneider Electric TSXCTZ2A counter module for Modicon TSX Micro — 2 inputs, 24 V DC, verified…
Schneider Electric
ATV930D55N4
Genuine surplus Schneider ATV930D55N4 drive — 55 kW, 380–480 V, dual ND/HD rating, verified condition and ready to…
Schneider Electric
ATV610D55N4
Genuine surplus Schneider Electric ATV610D55N4 drive, 55 kW, 380...460 V, C3 EMC filter — verified condition, ready to…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…