Schneider Electric Drives & Inverters
Schneider Electric ATV61HU40N4
Variable Speed Drive
Genuine surplus Schneider Electric ATV61HU40N4 Altivar 61 drive, 4 kW, 380–480 V, verified condition and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Power Rating | 4 kW / 5 HP |
|---|---|
| Supply Voltage | 380-480 V, 3-phase |
| Supply Frequency | 50/60 Hz |
| Line Current | 5.4 A |
| Apparent Power | 5.5 kVA |
| Nominal Switching Frequency | 12 kHz |
| Switching Frequency Range | 1-16 kHz adjustable |
| Maximum Transient Current | 7.5 A (60 seconds) |
| EMC Filter | Integrated EMC filter |
| Protection Rating | IP20 |
Description
When a 4 kW motor drive fails on a running line, every hour of downtime adds cost. The Schneider Electric ATV61HU40N4 is a genuine surplus Altivar 61 variable speed drive rated 4 kW / 5 HP at 380–480 V, 3-phase — a practical replacement for maintenance teams that need verified condition without waiting on OEM lead times.
What This Altivar 61 Drive Does
The Altivar 61 family is built for precise motor control in industrial settings, and this unit carries the core ratings that matter on the floor: 4 kW / 5 HP output, 5.4 A line current, and 5.5 kVA apparent power. It accepts a 380–480 V three-phase supply at 50/60 Hz, so it fits installations across different regional power systems. An integrated EMC filter reduces electromagnetic interference, which helps in panels where sensitive signalling runs alongside power cabling. The IP20 rating suits indoor cabinet mounting with a basic barrier against dust and accidental contact, and the assembly includes a heat sink for thermal dissipation. Nominal switching frequency is 12 kHz, adjustable from 1 to 16 kHz to match application needs. Maximum transient current is 7.5 A for up to 60 seconds, covering short-term overload conditions.

Surplus Advantage for This Drive
Altivar 61 units are no longer the newest line Schneider Electric offers, which is exactly why surplus stock matters. A refurbished ATV61HU40N4 from Autronexa is tested against OEM datasheet specifications and functionally verified by our sourcing team before it ships. You get a genuine part, verified, at a fraction of the cost of chasing remaining new stock — and without the lead time a factory order can carry. For maintenance managers keeping existing Altivar 61 panels running, this is the practical route: match the model, confirm condition, and get the drive back into service.

Selection and Sourcing Guide
Before ordering, confirm your existing unit matches this configuration: 4 kW / 5 HP, 380–480 V three-phase, 5.4 A line current, and the integrated EMC filter. Check whether your panel expects the heat-sink assembly style shown here. Decide between surplus and refurbished condition based on how critical the application is — both are genuine, but refurbished units carry our functional verification. Accessories, cabling, and mounting hardware are not included unless stated. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this ATV61HU40N4 a genuine Schneider Electric drive or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. This is a genuine Schneider Electric Altivar 61 drive, not a copy.
What condition will the ATV61HU40N4 arrive in?
Our default condition is Refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — confirm the condition you need when you request a quote.
How fast can Autronexa ship the ATV61HU40N4?
Lead time depends on current stock. Contact Autronexa with the part number for verified condition and current availability; surplus and refurbished units are ready to ship when in stock.
Does the ATV61HU40N4 suit a 400 V three-phase supply?
Yes. The drive accepts 380–480 V, 3-phase at 50/60 Hz, so it fits 400 V systems within that range. Confirm your motor rating matches the 4 kW / 5 HP output before ordering.
Is the Altivar 61 series still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before you plan the replacement.
Related & compatible parts
Schneider Electric
ATV610D11N4Z
Genuine surplus Schneider ATV610D11N4Z, 11 kW drive with C3 EMC filter — verified condition, ready to ship from…
Schneider Electric
PC-E984-285
Genuine surplus Schneider Electric PC-E984-285 Modicon CPU, 32k logic / 64k data memory, verified and ready to ship.
Schneider Electric
52-0422-000
Genuine surplus Schneider Electric 52-0422-000 trunk terminator for Modicon Quantum coaxial networks — verified condition, ready to ship.
Schneider Electric
BMXDDI1603
Genuine surplus Schneider Electric BMXDDI1603 Modicon X80 16-channel discrete input module, verified and ready to ship.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…