Bently Nevada Vibration Monitoring 3500
Bently Nevada 3500/61-02-02
Temperature Monitors with Recorder Outputs
Bently Nevada 3500/61-02-02 Temperature Monitors with Recorder Outputs. Bulkhead Rack: ±3 °C at 25 °C (±5.4 °F at 77 °F).
- Available on request
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
Technical specifications
| Manufacturer | Bently Nevada |
|---|---|
| Product No. | 3500/61-02-02 |
| Product type | Temperature Monitors with Recorder Outputs |
| I/O Module Type | 0 2 = RTD/TC Non-isolated I/O Module |
| Agency Approval Option | 0 2 = ATEX/ IECEx/ CSA (Class 1, Zone 2) |
| Signal Accepts from 1 to 6 RTD or TC | transducer signals. |
| Impedance | 10 MΩ for each lead input. |
| Power Consumption | 3500/60 Nominal consumption of 7 watts. 3500/61 Nominal consumption of 9 watts. |
| TCs | Type E -100 °C to +1000 °C, (-148 °F to +1832 °F). |
| When using any of the isolated | thermocouple I/O modules (-03 or -04 |
| Isolated I/O Module System Isolation | 500Vdc |
| Channel to Channel Isolation | 250 Vdc Isolation is only required for fault scenarios and these voltages will not be present on the I/O module inputs when a wiring or field fault occurs. |
| OK LED | Indicates when the Temperature Monitor is operating properly. |
| TX/RX LED | Indicates then the Temperature Monitor is communicating with other modules in the 3500 rack. |
| Voltage Compliance (current output) | 0 to +12 Vdc range across load. Load resistance is 0 to 600 Ω. |
| Resolution | 0.3662 µA per bit ±0.15% error at room temperature ±0.4% error over temperature range. |
| Internal Termination NonIsolated | ±3 °C at 25 °C (±5.4 °F at 77 °F). |
| Bulkhead Rack | ±3 °C at 25 °C (±5.4 °F at 77 °F). |
| Standard Rack | ±3 °C at 25 °C (±5.4 °F at 77 °F). |
| Standard Rack | ±1 °C at 25 °C (±1.8 °F at 77 °F). |
| Bulkhead Rack | ±2 °C at 25 °C (±3.6 °F at 77 °F). ±3 °C at 25 °C ±5.4 °F at 77 °F). Standard Rack: ±3 °C at 25 °C ±5.4 °F at 77 °F). |
| External Termination Isolated | Bulkhead Rack: ±1 °C at 25 °C (±1.8 °F at 77 °F). Standard Rack: °C at 25 °C (±1.8 °F at 77 °F) 10 Ω Copper RTDs Resolution 1°C or 1 °F Accuracy ±3 °C at 25 °C |
| Temprature | -30°C to +65°C (-22°F to +150 °F) when used with |
| I/O Modules | 0°C to +65 °C (32 °F to +150 °F) when used with Internal Barrier |
| Temperature | -40°C to +85°C (-40°F to +185°F) |
| Dimensions | (Height x Width x |
| Depth) | 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in) |
| Depth) | 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in) |
| Depth) | 241.3 mm x 24.4 mm x 163.1 mm (9.50 in x 0.96 in x 6.42 in) |
| Module | 1 full-height front slot |
Description
The Bently Nevada 3500/61-02-02 is a temperature monitors with recorder outputs for the 3500 Machinery Protection System. It conditions field transducer signals into vibration and position measurements and compares them against programmable alarm setpoints inside the 3500 rack. and has a nominal power consumption of 3500/60 nominal consumption of 7 watts. 3500/61 nominal consumption of 9 watts. with 250 vdc isolation is only required for fault scenarios and these voltages will not be present on the i/o module inputs when a wiring or field fault occurs. Dimensions are (height x width x It monitors critical rotating equipment such as turbines, compressors, and pumps, and communicates monitor status and measured values to the 3500 rack and to recorder outputs for machinery protection. Configuration is performed with 3500 Rack Configuration Software; no field calibration is required.
Product Identification
- Manufacturer: Bently Nevada.
- Product No.: 3500/61-02-02.
- Product type: Temperature Monitors with Recorder Outputs.
Ordering & Configuration
- I/O Module Type: 0 2 = RTD/TC Non-isolated I/O Module.
- Agency Approval Option: 0 2 = ATEX/ IECEx/ CSA (Class 1, Zone 2).
- Signal Accepts from 1 to 6 RTD or TC: transducer signals..
Electrical & Signal
- Impedance: 10 MΩ for each lead input..
- Power Consumption: 3500/60 Nominal consumption of 7 watts. 3500/61 Nominal consumption of 9 watts..
- Isolated I/O Module System Isolation: 500Vdc.
- Channel to Channel Isolation: 250 Vdc Isolation is only required for fault scenarios and these voltages will not be present on the I/O module inputs when a wiring or field fault occurs..
- Voltage Compliance (current output): 0 to +12 Vdc range across load. Load resistance is 0 to 600 Ω..
- Resolution: 0.3662 µA per bit ±0.15% error at room temperature ±0.4% error over temperature range..
Environmental Ratings
- Temperature: -40°C to +85°C (-40°F to +185°F).
Physical & Mechanical
- Dimensions: (Height x Width x.
Specifications
- TCs: Type E -100 °C to +1000 °C, (-148 °F to +1832 °F)..
- When using any of the isolated: thermocouple I/O modules (-03 or -04.
- OK LED: Indicates when the Temperature Monitor is operating properly..
- TX/RX LED: Indicates then the Temperature Monitor is communicating with other modules in the 3500 rack..
- Internal Termination NonIsolated: ±3 °C at 25 °C (±5.4 °F at 77 °F)..
- Bulkhead Rack: ±3 °C at 25 °C (±5.4 °F at 77 °F)..
- Standard Rack: ±3 °C at 25 °C (±5.4 °F at 77 °F)..
- Standard Rack: ±1 °C at 25 °C (±1.8 °F at 77 °F)..
- Bulkhead Rack: ±2 °C at 25 °C (±3.6 °F at 77 °F). ±3 °C at 25 °C ±5.4 °F at 77 °F). Standard Rack: ±3 °C at 25 °C ±5.4 °F at 77 °F)..
- External Termination Isolated: Bulkhead Rack: ±1 °C at 25 °C (±1.8 °F at 77 °F). Standard Rack: °C at 25 °C (±1.8 °F at 77 °F) 10 Ω Copper RTDs Resolution 1°C or 1 °F Accuracy ±3 °C at 25 °C.
- Temprature: -30°C to +65°C (-22°F to +150 °F) when used with.
- I/O Modules: 0°C to +65 °C (32 °F to +150 °F) when used with Internal Barrier.
- Depth): 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in).
- Depth): 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in).
- Depth): 241.3 mm x 24.4 mm x 163.1 mm (9.50 in x 0.96 in x 6.42 in).
- Module: 1 full-height front slot.
Model Comparison
Compare the 3500/61-02-02 against the closest Bently Nevada configurations below to confirm ordering options, ratings and physical interchange.
| Model | Product No. | I/O Module Type | Agency Approval Option | Power Consumption | Manufacturer | Product type | Signal Accepts from 1 to 6 RTD or TC | Impedance |
|---|---|---|---|---|---|---|---|---|
| 3500/61-02-02 | 3500/61-02-02 | 0 2 = RTD/TC Non-isolated I/O Module | 0 2 = ATEX/ IECEx/ CSA (Class 1, Zone 2) | 3500/60 Nominal consumption of 7 watts. 3500/61 Nominal consumption of 9 watts. | Bently Nevada | Temperature Monitors with Recorder Outputs | transducer signals. | 10 MΩ for each lead input. |
| 3500/61-02-00 | 3500/61-02-00 | 0 2 =RTD/TC Non-isolated I/O Module | 00 = None | 3500/61 Nominal consumption of 9 watts. | Bently Nevada | Temperature Monitors with Recorder Outputs | transducer signals. | 10 MΩ for each lead input. |
| 3500/61-02-01 | 3500/61-02-01 | 0 2= RTD/TC Non-isolated I/O Module | 0 1= CSA/NRTL/C (Class 1, Div 2) | 3500/60 Nominal consumption of 7 watts. 3500/61 Nominal consumption of 9 watts. | Bently Nevada | Temperature Monitors with Recorder Outputs | transducer signals. | 10 MΩ for each lead input. |
| 3500/61-01-02 | 3500/61-01-02 | 01 = RTD/TC Non-isolated I/O Module Internal Terminations | 0 2 = ATEX/ IECEx/ CSA (Class 1, Zone 2) | 3500/60 Nominal consumption of 7 watts. 3500/61 Nominal consumption of 9 watts. | Bently Nevada | Temperature Monitors with Recorder Outputs | transducer signals. | 10 MΩ for each lead input. |
| 3500/61-03-02 | 3500/61-03-02 | 0 3= TC Isolated I/O Module Internal | 0 2 =ATEX/ IECEx/ CSA (Class 1, Zone 2) | 3500/61 Nominal consumption of 9 watts. | Bently Nevada | Temperature Monitors with Recorder Outputs | transducer signals. | 10 MΩ for each lead input. |
| 3500/61-04-02 | 3500/61-04-02 | 0 4 TC Isolated I/O Module External Terminations | 0 2 = ATEX/ IECEx/ CSA (Class 1, Zone 2) | 3500/60 Nominal consumption of 7 watts. 3500/61 Nominal consumption of 9 watts. | Bently Nevada | Temperature Monitors with Recorder Outputs | transducer signals. | 10 MΩ for each lead input. |
| 3500/61-01-00 | 3500/61-01-00 | 01 = RTD/TC Non-isolated I/O Module Internal Terminations | 00 = None | 3500/60 Nominal consumption of 7 watts. 3500/61 Nominal consumption of 9 watts. | Bently Nevada | Temperature Monitors with Recorder Outputs | transducer signals. | 10 MΩ for each lead input. |
Frequently asked questions
What is the Bently Nevada 3500/61-02-02 and what does it do?
The Bently Nevada 3500/61-02-02 is a temperature monitors with recorder outputs for the 3500 Machinery Protection System. It conditions field transducer signals into vibration and position measurements and compares them against user-programmable alarm setpoints within the 3500 rack.
What is the power consumption of the 3500/61-02-02?
The 3500/61-02-02 has a nominal power consumption of 3500/60 Nominal consumption of 7 watts. 3500/61 Nominal consumption of 9 watts. It draws power from the 3500 rack backplane and requires no separate supply.
What are the physical dimensions of the 3500/61-02-02?
The 3500/61-02-02 measures (Height x Width x and weighs It occupies a standard 3500 rack slot and installs on the rack backplane.
How is the 3500/61-02-02 installed and configured?
The 3500/61-02-02 mounts in a 3500 rack rear slot and draws power from the rack backplane. Channels are configured with 3500 Rack Configuration Software; alarm setpoints and full-scale ranges are set in software with no field calibration required.
Related & compatible parts
Bently Nevada · 3500/40M
132234-01
Bently Nevada 132234-01 External Termination Block. Connector Type: Terminal strip connectors. Supplied for MRO and OEM replacement use.
Bently Nevada
106769-01
Genuine Bently Nevada 106769-01 interconnect cable, 1 ft (0.3 m), 0.5 kg. Verified surplus stock for reliable transducer-to-monitor…
Bently Nevada · 330903 / 330905 / 330908 Series
330905-05-13-10-02-00
Bently Nevada 330905-05-13-10-02-00 Proximity Probes & Sensors. Connector and Cable Type: Miniature coaxial ClickLoc connector.
Bently Nevada · 3500/40M
129525-0100-01
Bently Nevada 129525-0100-01 Transducer Cable. Cable Length: 100 feet (30.5 metres); Assembly: Not assembled.
News & guides for Bently Nevada
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Bently Nevada 3500/91 EGD Gateway: Mark VIe Interface, Slots and Limits
TL;DR: The Bently Nevada 3500/91 is the EGD (Ethernet Global Data) communication gateway for a 3500 rack. It publishes rack,…
Bently Nevada 3500/50M Tachometer Module: Channels, Alarms, Spares
The 3500/50M is a two-channel speed module with no onboard relay contacts and no numeric display. What it measures, how…
Bently Nevada Orbit 60 conneX: Bidirectional DCS Interface
Bently Nevada’s Orbit 60 condition monitoring platform connects to the rest of the plant through conneX—a bidirectional digital interface that…
Bently Nevada 3500 Machinery Protection System: Specifications and Configuration
The Bently Nevada 3500 Machinery Protection System is a rack-based, modular monitoring and protection platform for rotating machines such as…
Bently Nevada 3300 XL Proximity Probe: Materials, Ratings, and Mounting
The Bently Nevada 3300 XL proximity transducer system measures radial vibration, axial position, and phase reference on rotating machinery shafts.…
Bently Nevada 32000 Metric Probe Housing: Construction and Protection Ratings
The Bently Nevada 32000 Metric Proximity Probe Housing is a mounting assembly that secures a 3300 XL proximity probe in…
