Bently Nevada Vibration Monitoring 3500

Bently Nevada 3500/61-04-02

Temperature Monitors with Recorder Outputs

Manufacturer: Bently Nevada Part Number: 3500/61-04-02

Bently Nevada 3500/61-04-02 Temperature Monitors with Recorder Outputs. Bulkhead Rack: ±3 °C at 25 °C (±5.4 °F at 77 °F).

  • Available on request
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

Technical specifications

Manufacturer Bently Nevada
Product No. 3500/61-04-02
Product type Temperature Monitors with Recorder Outputs
I/O Module Type 0 4 TC Isolated I/O Module External Terminations
Agency Approval Option 0 2 = ATEX/ IECEx/ CSA (Class 1, Zone 2)
Signal Accepts from 1 to 6 RTD or TC transducer signals.
Impedance 10 MΩ for each lead input.
Power Consumption 3500/60 Nominal consumption of 7 watts. 3500/61 Nominal consumption of 9 watts.
TCs Type E -100 °C to +1000 °C, (-148 °F to +1832 °F).
When using any of the isolated thermocouple I/O modules (-03 or -04
Isolated I/O Module System Isolation 500Vdc
Channel to Channel Isolation 250 Vdc Isolation is only required for fault scenarios and these voltages will not be present on the I/O module inputs when a wiring or field fault occurs.
OK LED Indicates when the Temperature Monitor is operating properly.
TX/RX LED Indicates then the Temperature Monitor is communicating with other modules in the 3500 rack.
Voltage Compliance (current output) 0 to +12 Vdc range across load. Load resistance is 0 to 600 Ω.
Resolution 0.3662 µA per bit ±0.15% error at room temperature ±0.4% error over temperature range.
Internal Termination NonIsolated ±3 °C at 25 °C (±5.4 °F at 77 °F).
Bulkhead Rack ±3 °C at 25 °C (±5.4 °F at 77 °F).
Standard Rack ±3 °C at 25 °C (±5.4 °F at 77 °F).
Standard Rack ±1 °C at 25 °C (±1.8 °F at 77 °F).
Bulkhead Rack ±2 °C at 25 °C (±3.6 °F at 77 °F). ±3 °C at 25 °C ±5.4 °F at 77 °F). Standard Rack: ±3 °C at 25 °C ±5.4 °F at 77 °F).
External Termination Isolated Bulkhead Rack: ±1 °C at 25 °C (±1.8 °F at 77 °F). Standard Rack: °C at 25 °C (±1.8 °F at 77 °F) 10 Ω Copper RTDs Resolution 1°C or 1 °F Accuracy ±3 °C at 25 °C
Temprature -30°C to +65°C (-22°F to +150 °F) when used with
I/O Modules 0°C to +65 °C (32 °F to +150 °F) when used with Internal Barrier
Temperature -40°C to +85°C (-40°F to +185°F)
Dimensions (Height x Width x
Depth) 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in)
Depth) 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
Depth) 241.3 mm x 24.4 mm x 163.1 mm (9.50 in x 0.96 in x 6.42 in)
Module 1 full-height front slot

Description

The Bently Nevada 3500/61-04-02 is a temperature monitors with recorder outputs for the 3500 Machinery Protection System. It conditions field transducer signals into vibration and position measurements and compares them against programmable alarm setpoints inside the 3500 rack. and has a nominal power consumption of 3500/60 nominal consumption of 7 watts. 3500/61 nominal consumption of 9 watts. with 250 vdc isolation is only required for fault scenarios and these voltages will not be present on the i/o module inputs when a wiring or field fault occurs. Dimensions are (height x width x It monitors critical rotating equipment such as turbines, compressors, and pumps, and communicates monitor status and measured values to the 3500 rack and to recorder outputs for machinery protection. Configuration is performed with 3500 Rack Configuration Software; no field calibration is required.

Product Identification

  • Manufacturer: Bently Nevada.
  • Product No.: 3500/61-04-02.
  • Product type: Temperature Monitors with Recorder Outputs.

Ordering & Configuration

  • I/O Module Type: 0 4 TC Isolated I/O Module External Terminations.
  • Agency Approval Option: 0 2 = ATEX/ IECEx/ CSA (Class 1, Zone 2).
  • Signal Accepts from 1 to 6 RTD or TC: transducer signals..

Electrical & Signal

  • Impedance: 10 MΩ for each lead input..
  • Power Consumption: 3500/60 Nominal consumption of 7 watts. 3500/61 Nominal consumption of 9 watts..
  • Isolated I/O Module System Isolation: 500Vdc.
  • Channel to Channel Isolation: 250 Vdc Isolation is only required for fault scenarios and these voltages will not be present on the I/O module inputs when a wiring or field fault occurs..
  • Voltage Compliance (current output): 0 to +12 Vdc range across load. Load resistance is 0 to 600 Ω..
  • Resolution: 0.3662 µA per bit ±0.15% error at room temperature ±0.4% error over temperature range..

Environmental Ratings

  • Temperature: -40°C to +85°C (-40°F to +185°F).

Physical & Mechanical

  • Dimensions: (Height x Width x.

Specifications

  • TCs: Type E -100 °C to +1000 °C, (-148 °F to +1832 °F)..
  • When using any of the isolated: thermocouple I/O modules (-03 or -04.
  • OK LED: Indicates when the Temperature Monitor is operating properly..
  • TX/RX LED: Indicates then the Temperature Monitor is communicating with other modules in the 3500 rack..
  • Internal Termination NonIsolated: ±3 °C at 25 °C (±5.4 °F at 77 °F)..
  • Bulkhead Rack: ±3 °C at 25 °C (±5.4 °F at 77 °F)..
  • Standard Rack: ±3 °C at 25 °C (±5.4 °F at 77 °F)..
  • Standard Rack: ±1 °C at 25 °C (±1.8 °F at 77 °F)..
  • Bulkhead Rack: ±2 °C at 25 °C (±3.6 °F at 77 °F). ±3 °C at 25 °C ±5.4 °F at 77 °F). Standard Rack: ±3 °C at 25 °C ±5.4 °F at 77 °F)..
  • External Termination Isolated: Bulkhead Rack: ±1 °C at 25 °C (±1.8 °F at 77 °F). Standard Rack: °C at 25 °C (±1.8 °F at 77 °F) 10 Ω Copper RTDs Resolution 1°C or 1 °F Accuracy ±3 °C at 25 °C.
  • Temprature: -30°C to +65°C (-22°F to +150 °F) when used with.
  • I/O Modules: 0°C to +65 °C (32 °F to +150 °F) when used with Internal Barrier.
  • Depth): 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in).
  • Depth): 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in).
  • Depth): 241.3 mm x 24.4 mm x 163.1 mm (9.50 in x 0.96 in x 6.42 in).
  • Module: 1 full-height front slot.

Model Comparison

Compare the 3500/61-04-02 against the closest Bently Nevada configurations below to confirm ordering options, ratings and physical interchange.

Model Product No. I/O Module Type Agency Approval Option Power Consumption Manufacturer Product type Signal Accepts from 1 to 6 RTD or TC Impedance
3500/61-04-02 3500/61-04-02 0 4 TC Isolated I/O Module External Terminations 0 2 = ATEX/ IECEx/ CSA (Class 1, Zone 2) 3500/60 Nominal consumption of 7 watts. 3500/61 Nominal consumption of 9 watts. Bently Nevada Temperature Monitors with Recorder Outputs transducer signals. 10 MΩ for each lead input.
3500/61-04-01 3500/61-04-01 0 4 =TC Isolated I/O Module External 0 1= CSA/NRTL/C (Class 1, Div 2) 3500/61 Nominal consumption of 9 watts. Bently Nevada Temperature Monitors with Recorder Outputs transducer signals. 10 MΩ for each lead input.
3500/61-01-02 3500/61-01-02 01 = RTD/TC Non-isolated I/O Module Internal Terminations 0 2 = ATEX/ IECEx/ CSA (Class 1, Zone 2) 3500/60 Nominal consumption of 7 watts. 3500/61 Nominal consumption of 9 watts. Bently Nevada Temperature Monitors with Recorder Outputs transducer signals. 10 MΩ for each lead input.
3500/61-02-02 3500/61-02-02 0 2 = RTD/TC Non-isolated I/O Module 0 2 = ATEX/ IECEx/ CSA (Class 1, Zone 2) 3500/60 Nominal consumption of 7 watts. 3500/61 Nominal consumption of 9 watts. Bently Nevada Temperature Monitors with Recorder Outputs transducer signals. 10 MΩ for each lead input.
3500/61-03-02 3500/61-03-02 0 3= TC Isolated I/O Module Internal 0 2 =ATEX/ IECEx/ CSA (Class 1, Zone 2) 3500/61 Nominal consumption of 9 watts. Bently Nevada Temperature Monitors with Recorder Outputs transducer signals. 10 MΩ for each lead input.
3500/61-01-00 3500/61-01-00 01 = RTD/TC Non-isolated I/O Module Internal Terminations 00 = None 3500/60 Nominal consumption of 7 watts. 3500/61 Nominal consumption of 9 watts. Bently Nevada Temperature Monitors with Recorder Outputs transducer signals. 10 MΩ for each lead input.
3500/61-01-01 3500/61-01-01 01 = RTD/TC Non-isolated I/O Module Internal Terminations 0 1= CSA/NRTL/C (Class 1, Div 2) 3500/60 Nominal consumption of 7 watts. 3500/61 Nominal consumption of 9 watts. Bently Nevada Temperature Monitors with Recorder Outputs transducer signals. 10 MΩ for each lead input.

Frequently asked questions

What is the Bently Nevada 3500/61-04-02 and what does it do?

The Bently Nevada 3500/61-04-02 is a temperature monitors with recorder outputs for the 3500 Machinery Protection System. It conditions field transducer signals into vibration and position measurements and compares them against user-programmable alarm setpoints within the 3500 rack.

What is the power consumption of the 3500/61-04-02?

The 3500/61-04-02 has a nominal power consumption of 3500/60 Nominal consumption of 7 watts. 3500/61 Nominal consumption of 9 watts. It draws power from the 3500 rack backplane and requires no separate supply.

What are the physical dimensions of the 3500/61-04-02?

The 3500/61-04-02 measures (Height x Width x and weighs It occupies a standard 3500 rack slot and installs on the rack backplane.

How is the 3500/61-04-02 installed and configured?

The 3500/61-04-02 mounts in a 3500 rack rear slot and draws power from the rack backplane. Channels are configured with 3500 Rack Configuration Software; alarm setpoints and full-scale ranges are set in software with no field calibration required.

Related & compatible parts

Bently Nevada · 31000 / 32000 Series

31000-28-10-00-235-00-02

Bently Nevada 31000-28-10-00-235-00-02 Proximity Probe Housing. Sulfide (PPS) thermoplastic: containing conductive fibers.

Available on request

Bently Nevada · 31000 / 32000 Series

31000-28-05-70-066-00-02

Bently Nevada 31000-28-05-70-066-00-02 Proximity Probe Housing. Sulfide (PPS) thermoplastic: containing conductive fibers.

Available on request

Bently Nevada · 31000 / 32000 Series

31000-16-05-00-037-03-02

Bently Nevada 31000-16-05-00-037-03-02 Proximity Probe Housing. Probe Cable Length: 0.5 m (20 in); O-Ring Material: Neoprene®.

Available on request

Bently Nevada · 330105 / 330106 Series

330105-02-12-20-12-CN

Bently Nevada 330105-02-12-20-12-CN Cables & Connectors. Class I, Zone 0: AEx/Ex ia IIC T5...T1 Ga; Class I, Zone…

Available on request

News & guides for Bently Nevada

View all articles

Request a quote for this part

Part number: 3500/61-04-02

We reply within one business day.

3500/61-04-02 Quote reply within 1 business day