Bently Nevada Vibration Monitoring 3500
Bently Nevada 3500/92-04-01-01
3500 System Module
Bently Nevada 3500/92-04-01-01 3500 System Module. I/O Module Type: Ethernet/RS485 Modbus I/O Module; Memory Type: Low Memory.
- Available on request
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
Technical specifications
| Manufacturer | Bently Nevada |
|---|---|
| Product No. | 3500/92-04-01-01 |
| Product Type | The 3500/92 Communication Gateway |
| I/O Module Type | 04 = Ethernet/RS485 Modbus I/O Module |
| Memory Type | 01 = Low Memory |
| Agency Approval Option | 01 = CSA/NRTL/C |
| Main Board | Dimensions = 241 mm x 24.4 mm x 242 mm |
| Weight | 1.26 Kg |
| I/O Module | 5.6 Watts typical with |
| Data Types Collects data from | other modules in the rack, such as current measured values with time stamp, module statuses, and current alarm statuses, via a high speed internal network. |
| Exact data types | returned depend on module type and channel configuration. |
| Update Time | The data collection rate depends on rack configuration but will not exceed 1 second for all modules in the 3500 rack. |
| OK LED Indicates when the | 3500/92 is operating properly. |
| TX/RX LED Indicates when the | 3500/92 is communicating with other modules in the 3500 rack. |
| BNC Host Protocol Communication with | 3500 Configuration |
| Unit (RTU) transmission | mode. |
| Ethernet | Communication Link Ethernet, 10Mbps, and conforms to IEEE802.3 |
| Protocol Ethernet TCP/IP frame | and Modbus/TCP |
| Connection RJ-45 (telephone jack | style) for 10BASE-T |
| Temperature | -30°C to +65°C (-22°F to +149°F) |
| Temperature | -40°C to +85°C (-40°F to +185°F) Humidity 95%, non-condensing |
| Dimensions | (Height x Width x |
| Depth) | 241 mm x 24.4 mm x 242 mm (9.50 in x 0.96 in x 9.52 in) |
| FCC Rules. Operation is subject to the | following two conditions: l This device may not cause harmful interference. l This device must accept any interference received, including interference that may cause undesired operation. |
| EMC | European Community Directive: |
| EMC Directive 2014/30/EU | Standards: EN 61000-6-2; Immunity for |
| Industrial Environments | EN 61000-6-4; Emissions for |
| Electrical Safety | European Community Directive: |
| LV Directive 2014/35/EU | Standards: |
| RoHS | European Community Directive: |
| Maritime | DNV GL rules for classification – Ships, offshore units, and high speed and light craft ABS Rules for Condition of Classification, |
| Part 1 | l Steel Vessels Rules l Offshore Units and Structures |
Description
The Bently Nevada 3500/92-04-01-01 is a 3500 system module for the 3500 Machinery Protection System. It conditions field transducer signals into vibration and position measurements and compares them against programmable alarm setpoints inside the 3500 rack. Dimensions are (height x width x and the weight is 1.26 kg. It monitors critical rotating equipment such as turbines, compressors, and pumps, and communicates monitor status and measured values to the 3500 rack and to recorder outputs for machinery protection. Configuration is performed with 3500 Rack Configuration Software; no field calibration is required.
Product Identification
- Manufacturer: Bently Nevada.
- Product No.: 3500/92-04-01-01.
- Product Type: The 3500/92 Communication Gateway.
Ordering & Configuration
- I/O Module Type: 04 = Ethernet/RS485 Modbus I/O Module.
- Agency Approval Option: 01 = CSA/NRTL/C.
Environmental Ratings
- Temperature: -30°C to +65°C (-22°F to +149°F).
- Temperature: -40°C to +85°C (-40°F to +185°F) Humidity 95%, non-condensing.
Physical & Mechanical
- Weight: 1.26 Kg.
- Dimensions: (Height x Width x.
Compliance & Certifications
- FCC Rules. Operation is subject to the: following two conditions: l This device may not cause harmful interference. l This device must accept any interference received, including interference that may cause undesired operation..
- EMC: European Community Directive:.
- EMC Directive 2014/30/EU: Standards: EN 61000-6-2; Immunity for.
- Electrical Safety: European Community Directive:.
- LV Directive 2014/35/EU: Standards:.
- RoHS: European Community Directive:.
- Maritime: DNV GL rules for classification – Ships, offshore units, and high speed and light craft ABS Rules for Condition of Classification,.
Specifications
- Memory Type: 01 = Low Memory.
- Main Board: Dimensions = 241 mm x 24.4 mm x 242 mm.
- I/O Module: 5.6 Watts typical with.
- Data Types Collects data from: other modules in the rack, such as current measured values with time stamp, module statuses, and current alarm statuses, via a high speed internal network..
- Exact data types: returned depend on module type and channel configuration..
- Update Time: The data collection rate depends on rack configuration but will not exceed 1 second for all modules in the 3500 rack..
- OK LED Indicates when the: 3500/92 is operating properly..
- TX/RX LED Indicates when the: 3500/92 is communicating with other modules in the 3500 rack..
- BNC Host Protocol Communication with: 3500 Configuration.
- Unit (RTU) transmission: mode..
- Ethernet: Communication Link Ethernet, 10Mbps, and conforms to IEEE802.3.
- Protocol Ethernet TCP/IP frame: and Modbus/TCP.
- Connection RJ-45 (telephone jack: style) for 10BASE-T.
- Depth): 241 mm x 24.4 mm x 242 mm (9.50 in x 0.96 in x 9.52 in).
- Industrial Environments: EN 61000-6-4; Emissions for.
- Part 1: l Steel Vessels Rules l Offshore Units and Structures.
Model Comparison
Compare the 3500/92-04-01-01 against the closest Bently Nevada configurations below to confirm ordering options, ratings and physical interchange.
| Model | Temperature | Dimensions | Product No. | Agency Approval Option | Weight | Depth) | Manufacturer | I/O Module |
|---|---|---|---|---|---|---|---|---|
| 3500/92-04-01-01 | -40°C to +85°C (-40°F to +185°F) Humidity 95%, non-condensing | (Height x Width x | 3500/92-04-01-01 | 01 = CSA/NRTL/C | 1.26 Kg | 241 mm x 24.4 mm x 242 mm (9.50 in x 0.96 in x 9.52 in) | Bently Nevada | 5.6 Watts typical with |
| 3500/92-04-01-00 136188-02 | -40°C to +85°C (-40°F to +185°F) Humidity 95%, non-condensing | (Height x Width x | 3500/92-04-01-00 136188-02 | — | — | 241 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in) | Bently Nevada | 5.6 Watts typical with |
| 3500/94M-04-00-01 | -20°C to 65°C (-4°F to 149°F) | (W x H x D) 387.4 mm (15.25 in) x 248.9 mm (9.8 in) x 49.0 mm (1.93 in)Panel Cutout: 342.9 mm (13.5 in) x 228.6 mm (9.0 in) | 3500/94M-04-00-01 | 01 = CSA/NRTL/C (Class I, Division 2) | 1.07 Kg | — | Bently Nevada | — |
| 3500/94M-02-00-01 | range 0ºC to 45ºC (32ºF to 113ºF) Humidity 80%, non-condensing Class I, | (W x H x D) 387.4 mm (15.25 in) x 248.9 mm (9.8 in) x 49.0 mm (1.93 | — | — | — | — | Bently Nevada | — |
| 3500/94M-03-00-01 | -20°C to 65°C (-4°F to 149°F) | (W x H x D) 387.4 mm (15.25 in) x 248.9 mm (9.8 in) x 49.0 mm (1.93 in)Panel Cutout: 342.9 mm (13.5 in) x 228.6 mm (9.0 in) | 3500/94M-03-00-01 | 01 = CSA/NRTL/C (Class I, Division 2) | 1.07 Kg | — | Bently Nevada | — |
| 3500/94M-04-00-00 | -20°C to 65°C (-4°F to 149°F) | (W x H x D) 387.4 mm (15.25 in) x 248.9 mm (9.8 in) x 49.0 mm (1.93 in)Panel Cutout: 342.9 mm (13.5 in) x 228.6 mm (9.0 in) | 3500/94M-04-00-00 | 00 = None | 1.07 Kg | — | Bently Nevada | — |
| 3500/94M-04-00-02 | -20°C to 65°C (-4°F to 149°F) | (W x H x D) 387.4 mm (15.25 in) x 248.9 mm (9.8 in) x 49.0 mm (1.93 in)Panel Cutout: 342.9 mm (13.5 in) x 228.6 mm (9.0 in) | 3500/94M-04-00-02 | 02 = Multi (CSA/ATEX/IECEx) (only available for the 10" display) | 1.07 Kg | — | Bently Nevada | — |
Frequently asked questions
What is the Bently Nevada 3500/92-04-01-01 and what does it do?
The Bently Nevada 3500/92-04-01-01 is a component for the 3500 Machinery Protection System. It conditions field transducer signals into vibration and position measurements and compares them against user-programmable alarm setpoints within the 3500 rack.
What are the physical dimensions of the 3500/92-04-01-01?
The 3500/92-04-01-01 measures (Height x Width x and weighs 1.26 Kg It occupies a standard 3500 rack slot and installs on the rack backplane.
What standards does the 3500/92-04-01-01 comply with?
The 3500/92-04-01-01 complies with applicable EU directives and standards including European Community Directive:, Standards: EN 61000-6-2; Immunity for, Standards:. Review the full approvals list in the manufacturer datasheet before deployment.
How is the 3500/92-04-01-01 installed and configured?
The 3500/92-04-01-01 mounts in a 3500 rack rear slot and draws power from the rack backplane. Channels are configured with 3500 Rack Configuration Software; alarm setpoints and full-scale ranges are set in software with no field calibration required.
Related & compatible parts
Bently Nevada · 3500
3500/15 133292-01
Bently Nevada 3500/15 133292-01 Low Voltage Dc Power Supply Module. Input: voltage 20 to 30 Vdc; Power: supply…
Bently Nevada
3300/12-01-20-00
The Bently Nevada 3300/12 is the power supply module for the 3300 monitoring system, providing rack power and…
Bently Nevada · 31000 / 32000 Series
31000-28-10-00-114-03-02
Bently Nevada 31000-28-10-00-114-03-02 Proximity Probe Housing. Fittings: Two plugs, one 3/4-14 NPT fitting; O-Ring Material: Neoprene®.
Bently Nevada · 3500/40M
129525-0050-02
Bently Nevada 129525-0050-02 Transducer Cable. Cable Length: 50 feet (15.2 metres); Assembly: Not assembled.
News & guides for Bently Nevada
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Bently Nevada 3500/91 EGD Gateway: Mark VIe Interface, Slots and Limits
TL;DR: The Bently Nevada 3500/91 is the EGD (Ethernet Global Data) communication gateway for a 3500 rack. It publishes rack,…
Bently Nevada 3500/50M Tachometer Module: Channels, Alarms, Spares
The 3500/50M is a two-channel speed module with no onboard relay contacts and no numeric display. What it measures, how…
Bently Nevada Orbit 60 conneX: Bidirectional DCS Interface
Bently Nevada’s Orbit 60 condition monitoring platform connects to the rest of the plant through conneX—a bidirectional digital interface that…
Bently Nevada 3500 Machinery Protection System: Specifications and Configuration
The Bently Nevada 3500 Machinery Protection System is a rack-based, modular monitoring and protection platform for rotating machines such as…
Bently Nevada 3300 XL Proximity Probe: Materials, Ratings, and Mounting
The Bently Nevada 3300 XL proximity transducer system measures radial vibration, axial position, and phase reference on rotating machinery shafts.…
Bently Nevada 32000 Metric Probe Housing: Construction and Protection Ratings
The Bently Nevada 32000 Metric Proximity Probe Housing is a mounting assembly that secures a 3300 XL proximity probe in…