Schneider Electric Communication Modules
Schneider Electric BMXP342010
CPU Module
Genuine surplus Schneider Electric BMXP342010 Modicon M340 CPU module — verified condition, tested, and ready to ship from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Processor | ARM9 |
|---|---|
| Clock speed | 180 MHz |
| Program memory | 3584 KB (application + symbols + comments) |
| Data memory | 256 KB (data + constants) |
| Internal RAM | 4096 KB total |
| Built-in ports | 1× CANopen (RJ45), 1× Modbus Serial (RJ45, RS232/RS485), 1× USB Mini-B |
| Supply voltage | 24 V DC (via backplane) |
| Power consumption | 2.6 W |
| Operating temperature | 0°C to +60°C |
| Dimensions (H×W×D) | 100 × 28 × 93 mm |
Description
How do you keep a Modicon M340 line running when the exact CPU you need is weeks out from the OEM? The Schneider Electric BMXP342010 is a Level 2 performance CPU module for the M340 platform, and Autronexa supplies it as genuine surplus — verified against OEM datasheet markings, functionally tested, and available without the new-from-factory lead time.
What This CPU Module Does in an M340 System
The BMXP342010 runs the application program for a Modicon M340 station. Its ARM9 processor at 180 MHz executes at 8.1 Kinst/ms for 100% boolean and 6.4 Kinst/ms for mixed instructions, so scan time stays predictable as logic grows. Program memory is 3584 KB for application, symbols and comments, with 256 KB of data memory and 4096 KB total internal RAM. The module manages 1 main local rack plus 3 expansion racks across 4, 6, 8 and 12-slot X80 racks, supporting up to 1024 discrete and 256 analog I/O points and 36 application channels. Programming is done in EcoStruxure Machine Expert (Unity Pro).

Communications Built Into the Module
This variant carries a CANopen master port (RJ45, DS405, up to 63 slaves), a Modbus Serial port (RJ45, RS232/RS485, RTU/ASCII) and a USB Mini-B port. That combination covers most distributed I/O and drive networks without an extra module. Where Ethernet/IP or additional serial links are needed, the X80 range offers optional communication modules — confirm the exact module and cabling with your supplier before ordering. Integration Note: wiring into such networks may require an external gateway or connection module — confirm required cables and gateways with your supplier.

Why Genuine Surplus Fits This Platform
The M340 is an Active/Mature platform, and Schneider Electric recommends newer designs such as M580 for greenfield work. That leaves many installed M340 systems needing like-for-like CPU replacements rather than a migration. Autronexa stocks surplus and refurbished units tested against OEM datasheet specifications and functionally verified by our sourcing team, which shortens the wait compared with factory order cycles. Each unit is checked for the correct part number and port configuration before dispatch. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this BMXP342010 a genuine Schneider Electric module or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. The BMXP342010 you receive is a genuine Schneider Electric module, not a copy.
What condition will the CPU module arrive in?
Units ship in the site default condition, Refurbished — tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask us for the specific condition note on the unit reserved for your order.
How fast can Autronexa ship the BMXP342010?
Lead time depends on current stock at the time of your request. Contact Autronexa with your part number and we will confirm verified condition and current availability, including shipping timing.
Does this CPU work with CANopen and Modbus devices?
Yes. The module includes a CANopen master port (RJ45, DS405, up to 63 slaves) and a Modbus Serial port (RJ45, RS232/RS485, RTU/ASCII). Confirm your network layout and cabling with our sourcing team before ordering.
Is the Modicon M340 platform still supported by Schneider Electric?
The platform is listed as Active/Mature, with newer designs such as M580 recommended. Please verify current lifecycle status and OEM support with Autronexa before ordering.
Related & compatible parts
Schneider Electric
BMENOC0321C
Genuine surplus Schneider Electric BMENOC0321C communication module for Modicon M580 — verified condition, faster than OEM lead times.
Schneider Electric
ATV310H037N4E
Genuine surplus Schneider ATV310H037N4E drive, 0.37 kW, 380...460 V three-phase — verified condition and practical sourcing support from…
Schneider Electric
110XTS00122
Genuine surplus Schneider Electric 110XTS00122 I/O base module for Modicon Momentum — verified condition, practical sourcing support.
Schneider Electric
ATV930U15N4
Genuine surplus Schneider ATV930U15N4 Altivar 930 drive — dual-rated 1.5 kW ND / 0.75 kW HD, verified condition…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…