Schneider Electric Cables & Connectors
Schneider Electric 110XTS00122
I/O base module within Schneider Electric's Modicon Momentum series
Genuine surplus Schneider Electric 110XTS00122 I/O base module for Modicon Momentum — verified condition, practical sourcing support.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Mounting Type | DIN Rail or Panel Mount |
|---|---|
| Bus Type | Modbus Plus / Ethernet Communication |
| Number of Slots | 1 Base Slot |
| Supported Devices | Momentum Processor and I/O Modules |
| Operating Voltage | 5 VDC (from Processor Module) |
| Protection Class | IP20 |
| Material | High-impact plastic |
| Operating Temperature | 0 °C to 60 °C |
| Storage Temperature | -40 °C to 85 °C |
| Humidity | 5% to 95% non-condensing |
Description
The Schneider Electric 110XTS00122 is a Modicon Momentum I/O base module that carries a Momentum processor and one I/O module, drawing 5 VDC from the processor. Maintenance and procurement teams choose genuine surplus or refurbished units of this base when they need to keep an existing Momentum rack running without waiting on OEM lead times. Autronexa verifies each unit against OEM datasheet markings before it ships.
What This Base Module Does in a Momentum System
The base module is the physical and electrical foundation of a Momentum assembly. It accepts a Momentum processor and one I/O module in its single base slot, and it supplies the operating voltage of 5 VDC from the processor module to the mounted electronics. Because the base carries both the processor and the I/O, it determines how the assembly is mounted and how it communicates. This variant supports Modbus Plus or Ethernet communication, so it fits architectures built around either bus. The housing is high-impact plastic with an IP20 protection class, which suits it to cabinet interiors rather than exposed plant-floor positions. Mounting is flexible: DIN rail or panel mount, so the same base can be fitted into existing enclosures during a repair or a rack expansion.

Technical Specs Breakdown
Three values matter most when you specify this base. First, the 5 VDC operating voltage is supplied from the processor module, not from a separate field supply, so the base has no independent power terminals to wire. Second, the IP20 rating and high-impact plastic housing set the installation environment: clean, enclosed cabinet space. Third, the operating temperature range of 0 °C to 60 °C and humidity tolerance of 5% to 95% non-condensing define the ambient conditions the assembly can tolerate. Storage from -40 °C to 85 °C gives you margin for spares held in unheated stores. The table below lists the full set of published parameters.

Surplus Advantage and Sourcing Guidance
For a base module, the sourcing question is rarely about features; it is about whether the part is genuine and whether it arrives in time to restore a rack. Autronexa stocks genuine surplus and refurbished Momentum components, and each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team. That gives you a practical alternative to waiting on OEM lead time for a part that sits at the bottom of an existing assembly. Before ordering, confirm the exact model and revision match for your Momentum processor and I/O module, and confirm the condition you need — surplus or refurbished. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric 110XTS00122, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it is listed. The base module you receive is a genuine Schneider Electric unit, not a copy.
What condition will the 110XTS00122 arrive in?
Autronexa supplies this module as refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — confirm the condition you need when you request a quote.
How fast can Autronexa ship this base module?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability, and the team will confirm the shipping date.
Does the 110XTS00122 work with Modbus Plus and Ethernet?
Yes. The published data states that this base module supports Modbus Plus or Ethernet communication. Confirm your processor and I/O module match the base configuration before installation.
Is the 110XTS00122 still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before you plan the repair.
Related & compatible parts
Schneider Electric
ATV320U40N4WS
Genuine surplus Schneider ATV320U40N4WS 4 kW IP65 drive with disconnect and C2 EMC filter — verified condition, faster…
Schneider Electric
TM3DQ32UK
Genuine surplus Schneider TM3DQ32UK: 32 NPN transistor outputs, 24 V DC, HE-10. Verified condition, ready to ship.
Schneider Electric
XBTGT1130
Genuine surplus Schneider XBTGT1130 HMI display: 3.8 in LCD, 320 x 240 pixels, Ethernet/RS232/RS485. Verified condition, ready to…
Schneider Electric
ATV930D45N4
Genuine surplus Schneider ATV930D45N4 drive — 45 kW ND/37 kW HD, dual-rated, verified condition and ready to ship…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
