| Output Channels | 4 |
|---|---|
| Output Resolution | 12 bits |
| Output Current | -10…10 mA |
| Source Resistance | 0.1 Ohm |
| Max Cable Distance | 400 m |
| Linearity | 1 LSB (+/-) |
| Update Time | 3 ms |
| Max Power Dissipation | 4.5 W |
| Isolation Between Channels | 500 V for 1 minute |
| Bus Current Requirement | 700 mA |
Description
When an analog output channel drifts or fails on a running Modicon Quantum system, every hour of downtime adds pressure to maintenance and production teams. Sourcing a genuine Schneider Electric 140AVO02000C analog output module quickly — and knowing it is authentic — matters more than chasing a brand-new list price. Autronexa supplies verified surplus and refurbished units with clear condition notes and practical lead times.
What This Module Does in a Quantum Rack
The 140AVO02000C is a four-channel analog output module from Schneider Electric’s Modicon Quantum series. Each channel delivers a current output in the range of -10…10 mA, giving maintenance engineers a predictable signal path for controlling valves, drives, and other field devices that accept a current loop. The module requires four output words for addressing, so it slots into the existing I/O map without re-engineering the rack layout. A 12-bit output resolution provides fine granularity across that current range, which helps when a loop needs smooth, repeatable positioning rather than coarse steps.

Technical Specs That Matter on the Floor
Three values stand out for service work. First, the -10…10 mA output current range defines what field devices this module can drive directly. Second, the 0.1 Ohm source resistance supports signal integrity over the loop. Third, the 400 m maximum cable distance means the module can serve field devices across a large plant area without adding repeaters. The update time of 3 ms keeps the output responsive for dynamic control tasks, and channel-to-channel isolation rated at 500 V for one minute helps protect the module from voltage surges on one loop affecting another. Keep the 0.063 mA fuse rating in mind during inspection — a blown fuse is a common reason a single channel goes quiet while the rest of the module still reports healthy.

Why Surplus and Refurbished Fits This Module
Modicon Quantum installations remain in service long after new-product lead times stretch out. A verified surplus or refurbished unit keeps a running rack alive without waiting on a factory order. Autronexa’s refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team, so the module you receive has been checked for output behavior and isolation before it ships. That approach gives maintenance engineers a practical alternative to full list price while keeping the genuine parts, verified standard. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine Schneider Electric 140AVO02000C, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. The module carries CE marking as stated in the source data, and our sourcing team checks the label and connector layout before listing.
What condition will the 140AVO02000C arrive in?
Autronexa's default condition for this listing is Refurbished. Each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before shipment.
How fast can you ship the 140AVO02000C?
Contact Autronexa for current lead time. Surplus and refurbished stock moves quickly, and our team confirms availability and dispatch timing against your required date.
Does this module work with my existing Modicon Quantum rack?
The 140AVO02000C is a Modicon Quantum analog output module requiring four output words for addressing. Confirm your rack's I/O map and bus current budget of 700 mA before installation.
Is the 140AVO02000C still supported by Schneider Electric?
Lifecycle status is not stated in the available data. Contact Autronexa to verify OEM support status and current availability before ordering.
Related & compatible parts
Schneider Electric
ATV71HD15N4
Genuine surplus Schneider ATV71HD15N4, 15 kW 3-phase drive with integrated EMC filter and graphic terminal. Verified condition, ready…
Schneider Electric
140AIO33000
Genuine surplus Schneider Electric 140AIO33000 intrinsically safe analog output module — 8 outputs, verified condition, ready to ship.
Schneider Electric
ATV320U06N4W
Genuine surplus Schneider ATV320U06N4W: 0.55 kW, 380–500 V three-phase, IP66 wall-mount drive with C2 EMC filter — verified…
Schneider Electric
170ENT11002
Genuine surplus Schneider 170ENT11002 Ethernet adapter for Modicon Momentum — verified, tested, and ready to ship from Autronexa.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…