Technical specifications
| Power supply type | Redundant |
|---|---|
| Input voltage | 24 V (20...30 V) DC |
| Input current | 3800 mA |
| Output voltage | 5.1 V DC |
| Output current | 8 A redundant |
| Maximum input power interruption | 100 ms; 1 ms at 20 V |
| Associated fuse rating | 5 A, slow-blow |
| Alarm output | 1 NC, 6 A, 220 V power supply fault |
| Operating temperature | 32…140 °F (0…60 °C) |
| Net weight | 1.43 lb (0.65 kg) |
Description
When a Modicon Quantum rack loses its power supply, every I/O module behind it goes dark. The Schneider Electric 140CPS22400 is a redundant 24 V DC power supply module for the Quantum platform, and maintenance teams keep it on the shelf precisely because a failed supply stops the whole backplane. Autronexa supplies this unit as genuine surplus, verified before dispatch, so you replace the fault without waiting on an OEM allocation queue.
What This Module Does in a Quantum Rack
The 140CPS22400 takes a 24 V DC input across a 20…30 V DC window and delivers 5.1 V DC to the Quantum backplane at 8 A in redundant configuration. Redundancy is the point of this variant: two supplies share the load, so one can fail without dropping the rack. The module reports a fault through a single normally-closed alarm contact rated 6 A at 220 V, and a green PWR OK LED gives a local indication that the output is healthy. Input current sits at 3800 mA, and the unit tolerates a maximum input power interruption of 100 ms, with a tighter 1 ms window at 20 V. Internal overvoltage protection and an output overload trip at 2.3 times maximum rated input voltage for 1.3 ms are built in. A 5 A slow-blow fuse is the associated rating.

Why Genuine Surplus Fits This Power Supply
Power supplies are wear items. Electrolytics age, fans if present load up, and a supply that has run for a decade in a control cabinet is not the same as one on a shelf. That is why condition matters more here than for a passive component. Autronexa sources surplus and refurbished Quantum modules and tests each unit against OEM datasheet specifications, with functional verification by the sourcing team before it ships. You get a genuine Schneider assembly, not a re-labelled copy, at a fraction of the new-list route and without the lead time a factory order usually carries. For a rack that is already installed and validated, a verified surplus supply keeps the existing architecture intact — no re-engineering, no firmware surprises.

Sourcing Checklist Before You Order
Match the exact part number and confirm the redundant configuration is what your rack needs; the non-redundant Quantum supplies are not interchangeable in a redundant slot. Check the input voltage at your cabinet — this module expects 24 V DC, not AC. Confirm the alarm contact wiring scheme your system uses, since the NC contact is your only remote fault signal. Ask for the condition grade in writing: surplus, refurbished, or new surplus are different things, and Autronexa states which one you are receiving. If the unit is going into a Class 1 Division 2 area, note that the FM listing on this module is part of its certification set and should be confirmed against your installation requirements. Finally, verify current lifecycle status and availability with Autronexa before ordering, since Quantum is a mature platform and stock moves. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric 140CPS22400, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it is listed. The 140CPS22400 is supplied as genuine surplus or refurbished stock, not a grey-market copy.
What condition will the power supply arrive in?
The site default condition is Refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask Autronexa to confirm the specific grade of the unit in stock before you order.
How fast can Autronexa ship the 140CPS22400?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability, and the team will confirm the ship date for the unit on hand.
Does this module work in a redundant Quantum configuration?
Yes — the 140CPS22400 is the redundant variant, rated 8 A output at 5.1 V DC with a 24 V DC input range of 20...30 V. Confirm your rack wiring and alarm contact scheme against the module documentation before installation.
Related & compatible parts
Schneider Electric
PC-0984-385
Genuine surplus Schneider Electric PC-0984-385 CPU module for Modicon systems — verified condition, practical sourcing support.
Schneider Electric
52-0402-000
Genuine surplus Schneider Electric 52-0402-000 tap terminator for Modicon Quantum — verified, tested, and ready to ship.
Schneider Electric
140DAI75300
Genuine surplus Schneider Electric 140DAI75300 Modicon Quantum 32-channel 230 V AC discrete input module — verified condition, ready…
Schneider Electric
ATV71HD15N4Z
Genuine surplus Schneider ATV71HD15N4Z Altivar 71 drive, 15 kW, 380–480 V AC, verified condition and ready to ship.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…