Schneider Electric I/O & Function Modules
Schneider Electric 140DAI75300
VAC discrete input modules
Genuine surplus Schneider Electric 140DAI75300 Modicon Quantum 32-channel 230 V AC discrete input module — verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Discrete input number | 32 |
|---|---|
| Group of channels | 4 |
| Discrete input voltage | 230 V AC |
| Input current | 11.5 mA 57...63 Hz; 9.7 mA 47...53 Hz |
| Input impedance | 26500 Ohm capacitive 57...63 Hz; 31800 Ohm capacitive 47...53 Hz |
| Network frequency limits | 47…63 Hz |
| Isolation between group and bus | 1780 Vrms for 1 minute |
| Bus current requirement | 250 mA |
| Maximum power dissipation | 5 W |
| Net weight | 0.3 kg |
Description
When a Modicon Quantum rack loses its 230 V AC input module, every downstream interlock and status signal goes dark. The Schneider Electric 140DAI75300 is a 32-channel VAC discrete input module for the Quantum automation platform, and sourcing a genuine surplus or refurbished unit keeps that rack running without waiting on OEM lead times. Autronexa verifies each module against OEM datasheet markings before it ships.
What This Module Does in a Quantum Rack
The 140DAI75300 sits in a standard-format Quantum slot and presents 32 discrete inputs arranged in four groups of eight. It occupies two input words of addressing, so a single module covers a dense field-signal block without expanding the rack. The module is designed for 230 V AC field circuits, with an input current of 11.5 mA at 57…63 Hz and 9.7 mA at 47…53 Hz, and an input impedance of 26500 Ohm capacitive at 57…63 Hz or 31800 Ohm capacitive at 47…53 Hz. Network frequency limits span 47…63 Hz. The absolute maximum input is 264 V continuous, 312 V for 10 s, and 400 V for 1 cycle. Isolation between groups and between group and bus is rated 1780 Vrms for 1 minute. Bus current requirement is 250 mA, and maximum power dissipation is 5 W. Front-panel LEDs show bus communication (green), external fault (red), and per-channel input status (32 green).

Why Genuine Surplus Fits This Module
Quantum installations are long-lived, and This unit is a high-channel-count module that rarely sits on a shelf as new stock. Autronexa supplies genuine surplus and refurbished units tested against OEM datasheet specifications and functionally verified by our sourcing team. That means a 32-channel module with the full 1780 Vrms group isolation intact, not a partial or reworked board. Because these modules are pulled from decommissioned Quantum systems, availability tracks what comes out of service rather than a factory schedule — practical when a single failed input card would otherwise idle a whole rack. Please verify current lifecycle status and availability with Autronexa before ordering.

Sourcing Checks Before You Buy
Confirm the exact model string unit on the label, not a close variant, since the channel count and voltage class are configuration-specific. Check that the module format is standard and that your rack slot accepts a 32-channel card. Ask whether the unit is surplus or refurbished and request the verification record. The module carries CE marking, UL 508 and CSA C22.2 No 142 standards, and FM Class 1 Division 2 and cUL certifications — match these to your panel requirements. Operating range is 32…140 °F (0…60 °C) with 95 % relative humidity without condensation, and operating altitude up to 5000 m. Net weight is 0.3 kg. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric 140DAI75300, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. The module is supplied as genuine surplus or refurbished, not as a grey-market copy.
What condition will the 140DAI75300 arrive in?
Units ship in the site default condition, Refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask for the verification record with your order.
How fast can you ship the 140DAI75300?
Lead time depends on current surplus stock. Contact Autronexa for current lead time and availability before ordering.
Does this module work with Concept, Unity Pro, and ProWORX 32?
The datasheet lists Concept, Unity Pro, and ProWORX 32 as the supported software names for this module. Confirm your rack and addressing configuration with your controls engineer.
Is the 140DAI75300 still supported by Schneider Electric?
Lifecycle status is not stated in the available data. Contact Autronexa to verify OEM support status and current availability.
Related & compatible parts
Schneider Electric
ATV320U55N4C
Genuine surplus Schneider ATV320U55N4C Altivar drive — 5.5 kW, 380–500 V, Modbus/CANopen. Verified condition and clear lead times…
Schneider Electric
BMXXBP1200
Genuine surplus Schneider Electric BMXXBP1200 12-slot rack for Modicon M340 — verified condition, sourcing support from Autronexa.
Schneider Electric
TSXDSY08R5
Genuine surplus Schneider Electric TSXDSY08R5 discrete output module — 8 relay outputs, 12–24 V DC / 24–240 V…
Schneider Electric
140CRP93100
Genuine surplus Schneider 140CRP93100 RIO head-end adaptor for Modicon Quantum — verified condition, faster than OEM lead times.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…