Schneider Electric PLCs & Controllers
Schneider Electric 140CPU67261C
Unity Hot Standby Processor
Genuine surplus Schneider 140CPU67261C Hot Standby processor — verified, tested, and ready to ship with sourcing support from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Processor Speed | 266 MHz Clock Frequency |
|---|---|
| Memory Capacity | 11,264 kB RAM (1,536 kB for data); expandable via 8 MB PCMCIA |
| Local Rack Capacity | Dual local rack integration |
| Modular Slot Support | 2, 4, 6, 10, or 16 slots |
| Distributed I/O Capacity | 63 stations (1 rack, 3 Modbus Plus networks) |
| Remote I/O Support | 31 stations per network (S908, Quantum, X80) |
| Discrete I/O Points | 31,744 remote; 8,000 distributed per network |
| Analog I/O Points | 1,984 remote; 500 distributed per network |
| Communication Protocols | Ethernet TCP/IP, Modbus Plus, Profibus DP, USB, fiber optic |
| Bus Current Requirement | 2,760 mA |
Description
The Schneider Electric 140CPU67261C Unity Hot Standby Processor delivers fault-tolerant control for Modicon Quantum systems, and Autronexa supplies it as a verified surplus unit for maintenance teams facing OEM lead times. Engineers specify this processor when continuous operation matters most.
What This Hot Standby Processor Does in a Quantum System
The 140CPU67261C runs at a 266 MHz clock frequency and supports dual local rack integration, so a primary and standby PLC pair can share the control task without interruption. Its redundancy configuration covers hot standby operation, and the single-mode fiber optic link between primary and secondary PLCs reaches up to 16 km. The processor handles 31,744 remote discrete I/O points and 8,000 distributed points per Modbus Plus network, with analog capacity of 1,984 remote and 500 distributed points per network. Memory is 11,264 kB RAM, 1,536 kB of it for data, expandable through an 8 MB PCMCIA card. Note that local I/O is forbidden in Hot Standby applications — all I/O must be remote or distributed.

Why Genuine Surplus Fits This Processor
A hot standby CPU is rarely a spares-bin item; when one fails, the standby rack carries the plant until a replacement arrives. Autronexa stocks refurbished units tested against OEM datasheet specifications and functionally verified by our sourcing team, so the replacement matches the original configuration. This unit carries ATEX zone 2, IEC-Ex, CE, UL, and CSA listings, and surplus units retain those markings. Compared with ordering new through the OEM channel, surplus and refurbished stock shortens the wait and avoids full list price — practical when the priority is restoring redundancy, not upgrading the platform.

Matching This CPU to Your Existing Rack
Before ordering, confirm the exact part number and revision on your existing processor, because This unit is a specific Hot Standby variant within the Modicon Quantum line. Check that your rack supports the slot configuration you need — this unit covers 2, 4, 6, 10, or 16 slots — and that your network plan matches its connections: 6 Ethernet TCP/IP, 6 Modbus Plus, 6 Profibus DP, and 1 USB. The bus current requirement is 2,760 mA, so verify power budget against your existing supply. If you run distributed I/O over Modbus Plus, confirm the 63-station limit per network. Autronexa can cross-reference your current part number and confirm condition before shipment. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine Schneider Electric 140CPU67261C, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. The 140CPU67261C we ship is a genuine Schneider Electric processor, not a copy.
What condition will the processor arrive in?
Units ship in refurbished condition, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need details on the specific unit available.
How fast can you ship the 140CPU67261C?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability before placing an order.
Does this CPU work with my existing Modicon Quantum rack?
It supports 2, 4, 6, 10, or 16 slot configurations and dual local racks. Confirm your rack type and power budget — the bus current requirement is 2,760 mA — with Autronexa before ordering.
Is the 140CPU67261C still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability for this part number.
Related & compatible parts
Schneider Electric
iC60N 1P C16
Genuine surplus Schneider Electric iC60N 1P C16 circuit breaker — 16A C-curve, 6 kA, verified condition and clear…
Schneider Electric
TM5SBER2
Genuine surplus Schneider Electric TM5SBER2 remote receiver module for Modicon TM5 — verified condition, tested, and ready to…
Schneider Electric · Advantys STB
STBACI1230
Genuine surplus Schneider STBACI1230 analog input module — 2 channels, 0-20 mA, 12-bit, hot-swappable. Verified condition, ready to…
Schneider Electric
TCSESM043F23F0
Genuine surplus Schneider ConneXium managed switch with 4 copper ports, HiPER ring redundancy, and verified condition from Autronexa.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
