Schneider Electric Communication Modules
Schneider Electric 140CRA93100C
Adapter module within the Modicon Quantum series
Genuine surplus Schneider 140CRA93100C adapter module for Modicon Quantum — supports 27 I/O modules, verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Maximum Number of I/O Modules | 27 |
|---|---|
| Type of Cable | 75 Ohm Coaxial Cable |
| Transmission Rate | 1544 Mbit/s |
| Dynamic Range | 35 dB |
| Isolation Voltage | 500 V |
| Voltage Type | DC |
| Electrical Connection | Female Connector |
| Power Dissipation | 3 W |
| Bus Current Requirement | 600 mA |
| Resistance to Electrostatic Discharge | 4 kV / 8 kV |
Description
When a Modicon Quantum rack needs a working adapter module, the 140CRA93100C from Schneider Electric is the part that keeps up to 27 I/O modules communicating over a 75 Ohm coaxial cable at 1544 Mbit/s. Maintenance teams and integrators choose genuine surplus here because the module is verified against OEM datasheet markings and functionally tested before it ships, avoiding the long lead times that come with ordering new from the OEM.
What This Adapter Module Does in a Quantum System
The 140CRA93100C sits inside the Modicon Quantum family as the adapter that links a remote I/O drop to the rest of the control architecture. It manages a maximum of 27 I/O modules, which makes it a practical choice for larger distributed setups where a single rack must handle many points. Data moves across a 75 Ohm coaxial cable at a transmission rate of 1544 Mbit/s, and the module maintains a dynamic range of 35 dB. Electrical connection is a single female connector, and the unit draws 600 mA from the bus while dissipating 3 W. Isolation voltage is rated at 500 V for DC applications, so the module separates field-side signals from the backplane environment. Weighing 0.5 kg, it installs without adding meaningful mechanical load to the rack.

Surplus and Refurbished: Why It Fits This Module
Schneider Electric no longer positions every Modicon Quantum component as a current-production item, and sourcing a specific adapter module through official channels can mean extended waits. Autronexa keeps verified surplus and refurbished stock of Quantum parts, and each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before it leaves the warehouse. That means This unit you receive has been checked for the parameters that matter: the 27-module capacity, the 1544 Mbit/s transmission rate, the 500 V isolation, and the 600 mA bus draw. For a maintenance manager facing a line-down situation, that verification step is worth more than a promise of new stock weeks away. The cost position also differs from OEM list price, which matters when a single adapter module is the only thing standing between a running process and a stopped one.

Environmental Ratings and Sourcing Checks
The module is built to tolerate the electrical noise common in industrial cabinets. It resists electrostatic discharge at 4 kV contact and 8 kV air, and it withstands electromagnetic fields up to 10 V/m. Those ratings trace directly to the datasheet and tell you the unit is intended for real plant environments, not clean-room benches. Before ordering, confirm that your application uses a 75 Ohm coaxial cable and that your rack configuration stays within the 27 I/O module limit. Also verify the exact revision and connector type against your existing wiring. Autronexa can cross-reference the EAN 3595861136298 and the part number markings to confirm you receive the correct adapter. Please verify current lifecycle status and availability with Autronexa before ordering, since Quantum support varies by region and date code.
Frequently asked questions
Is this a genuine Schneider Electric 140CRA93100C, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference, including the EAN 3595861136298. We do not source grey-market copies.
What condition will the adapter module arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — contact us for current stock condition.
How fast can you ship the 140CRA93100C?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; surplus and refurbished units are ready to ship when in stock.
Does this module work with my existing Modicon Quantum rack?
It supports up to 27 I/O modules over a 75 Ohm coaxial cable at 1544 Mbit/s. Confirm your rack uses that cable type and stays within the module limit before ordering.
Is the 140CRA93100C still supported by Schneider Electric?
Lifecycle status varies by region and date code. Contact Autronexa to verify OEM support status and current availability before you commit to a purchase.
Related & compatible parts
Schneider Electric
ATV310H037N4E
Genuine surplus Schneider ATV310H037N4E drive, 0.37 kW, 380...460 V three-phase — verified condition and practical sourcing support from…
Schneider Electric
OTB1CODM9LP
Genuine surplus Schneider OTB1CODM9LP CANopen I/O module — 20 I/O, verified condition, faster than OEM lead time.
Schneider Electric
TSXDSY64T2K
Genuine surplus Schneider Electric TSXDSY64T2K: 64 solid-state 24 V DC outputs, verified condition, faster lead time than OEM.
Schneider Electric
TSXP574823M
Genuine surplus Schneider Electric TSXP574823M compact PLC — verified, tested, and ready to ship with sourcing support from…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…