Channels 8 relay outputs
Output type Relay (normally open), form C
Signal type AC/DC universal
Coil voltage 24V DC
Output voltage 24 to 230V AC / 5 to 30V DC
Power consumption 4 W maximum
Protection rating IP20
Dimensions (H×W×D) 125 × 141.5 × 47.5 mm
Weight 0.4 kg

Description

When a Modicon Momentum rack loses an output base module, the whole machine can stall while procurement chases a part the OEM no longer builds. The Schneider Electric 170DDO84000 — an 8-channel relay output base module — is exactly the kind of discontinued unit Autronexa keeps in verified surplus and refurbished stock, so maintenance teams can restore switching without waiting on a factory allocation.

What This Momentum Base Module Does

The 170DDO84000 belongs to Schneider Electric’s Modicon Momentum family, a distributed I/O line built to sit close to field devices rather than inside a central cabinet. This base module carries eight relay outputs, normally open, form C, with a 24V DC coil. Its contacts switch a universal AC/DC signal range — 24 to 230V AC or 5 to 30V DC — which is why one module can drive mixed loads such as contactor coils, indicator lamps, and small solenoid valves on the same rack. Maximum power consumption is 4 W, and the housing measures 125 × 141.5 × 47.5 mm at 0.4 kg, with an IP20 protection rating suited to enclosed panel environments. Because the module is discontinued, replacement stock now comes from the surplus channel rather than new production.

Figure 1: Front view of the Schneider Electric 170DDO84000 Module Modicon Momentum 8-channel Relay showing its physical design and enclosure.

Why Genuine Surplus Fits a Discontinued Module

Schneider Electric has discontinued this base module, so a brand-new unit from a distributor is no longer a realistic option. That changes the sourcing question: the practical choice is between untested pulls from unknown vendors and a verified surplus or refurbished unit with a documented condition. Autronexa sources genuine parts and checks each unit against OEM datasheet markings and part-number cross-reference before it enters stock. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. For a plant running an existing Momentum installation, that means you can keep the rack in service instead of redesigning the I/O architecture around a single failed output card.

Selection and Sourcing Checks

Before ordering, confirm the exact model string on your existing module — unit — because Momentum base modules differ by output type and channel count, and a relay base will not substitute for a transistor or triac variant. Decide whether your application needs surplus or refurbished condition and state that preference when you request a quote. Check that the eight form C relay outputs match the load types on your panel, and verify the 24V DC coil supply is present in your wiring. Please verify current lifecycle status and availability with Autronexa before ordering, since discontinued stock moves quickly. Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: 170DDO84000-datasheet.pdf

Frequently asked questions

Is this 170DDO84000 a genuine Schneider Electric module or a clone?

Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it is listed. We supply genuine surplus and refurbished Schneider Electric components, not grey-market copies.

What condition will the module arrive in?

The site default condition is Refurbished: units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — state your preference when you request a quote.

How fast can you ship the 170DDO84000?

Lead time depends on current stock at the time of your request. Contact Autronexa with your part number for verified condition and current availability; we confirm lead time before you commit.

Is the 170DDO84000 still supported by Schneider Electric?

The module is listed as discontinued (last verified 2026-09). Contact Autronexa to confirm OEM support status and current availability of surplus or refurbished stock.

Can this relay base module replace a different Momentum output base?

No — Momentum base modules differ by output type and channel count. Match the exact model string 170DDO84000 and confirm your loads suit eight normally open, form C relay outputs with a 24V DC coil.

Related & compatible parts

Schneider Electric

TSXSUP1011

Genuine surplus Schneider Electric TSXSUP1011 power supply for TSX Micro PLCs — 24 V AC/DC input, 24 V…

In Stock

Schneider Electric

ATV320U22N4C

Genuine surplus Schneider ATV320U22N4C drive — 2.2 kW, 380–500 V three-phase, integrated EMC filter, verified and ready to…

In Stock

Schneider Electric

170ADO54000

Genuine surplus Schneider Electric 170ADO54000 Modicon Momentum 16-channel AC Triac module — verified condition, ready to ship.

In Stock

Schneider Electric

BMXSDI3202

Genuine surplus Schneider Electric BMXSDI3202 Modicon X80 32-channel safety discrete input module, SIL3/PLe rated, verified and ready to…

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: 170DDO84000

We reply within one business day.

170DDO84000 Quote reply within 1 business day