Schneider Electric I/O & Function Modules
Schneider Electric 140ACI04000
Analogue input module
Genuine surplus Schneider 140ACI04000 analogue input module — 16 differential channels, verified condition, faster than OEM lead time.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Analogue input number | 16 |
|---|---|
| Input type | Differential |
| Analogue input resolution | 0...16000 counts 4...20 mA; 0...20000 counts 0...20 mA; 0...25000 counts 0...25 mA; 0...4095 counts 4...20 mA |
| Input impedance | 250 Ohm |
| Absolute accuracy error | +/- 0.125 % of full scale |
| Isolation between channels and bus | 1780 V AC 60 s |
| Update time | 15 ms 2 wires/4 wires |
| Power dissipation | 5 W |
| Ambient air temperature for operation | 32…140 °F (0…60 °C) |
Description
When a Modicon Quantum analogue input module fails, every hour of downtime costs production. The Schneider Electric 140ACI04000 is a 16-channel differential analogue input module for the Modicon Quantum automation platform. Autronexa supplies genuine surplus and refurbished units — verified against OEM datasheet markings — so you get a tested module without the OEM lead time.
What the 140ACI04000 Does in a Quantum Rack
This module converts field analogue signals into digital values the Quantum CPU can process. Its 16 differential inputs accept multirange current signals, and the single-pole low-pass filter (3 dB at 34 Hz ±25%) suppresses high-frequency noise on long field wiring. Each channel resolves to 0…16000 counts at 4…20 mA, 0…20000 counts at 0…20 mA, or 0…25000 counts at 0…25 mA. The module occupies 17 input words of addressing and updates every 15 ms for 2-wire and 4-wire configurations. Front-panel LEDs show bus communication, external faults, and per-channel on/fault status — practical for quick diagnostics during commissioning.

Surplus Advantage for This Quantum Module
OEM lead times on Quantum I/O can stretch weeks when a line is down. Autronexa stocks surplus and refurbished units that are tested against OEM datasheet specifications and functionally verified by our sourcing team. Because this is genuine surplus, not a grey-market clone, you get the same 1780 V AC channel-to-bus isolation and ±0.125% full-scale accuracy the platform expects. For maintenance teams carrying spares, a verified refurbished module is a practical alternative to paying full OEM list price. Contact Autronexa with your part number for verified condition and current availability.

Buyer’s Checklist Before You Order
Confirm your rack uses the Modicon Quantum platform and that your application needs 16 differential current inputs — not a mixed or voltage-only card. Check the addressing requirement: 17 input words must fit your existing configuration. Verify the module format is standard and that your enclosure can dissipate 5 W. This unit carries CE marking and UL 508 / CSA C22.2 No 142 standards; FM Class 1 Division 2 and cUL certifications are listed. Operating range is 0…60 °C (32…140 °F) at up to 95% relative humidity without condensation. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine Schneider Electric 140ACI04000, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. This is genuine surplus or refurbished Schneider Electric stock, not a grey-market copy.
What condition will the 140ACI04000 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — contact Autronexa for current condition grading.
How fast can you ship the 140ACI04000?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability — surplus and refurbished units are ready to ship when in stock.
Does this module work with my existing Modicon Quantum rack?
The 140ACI04000 is a standard-format module for the Modicon Quantum automation platform, requiring 17 input words of addressing. Confirm your rack configuration and addressing budget before ordering.
Is the 140ACI04000 still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before ordering.
Related & compatible parts
Schneider Electric · Advantys STB
STBDDI3610
Genuine surplus Schneider Electric STBDDI3610 digital input module — 6 channels, 24V DC, hot-swappable, verified condition and ready…
Schneider Electric
140DII33000
Genuine surplus Schneider Electric 140DII33000: Modicon Quantum 8-channel intrinsically safe input module, verified condition, faster than OEM lead…
Schneider Electric
TSXCANKCDF90T
Genuine surplus Schneider Electric CANopen SUB-D9 connector with line terminator — verified condition, practical lead times from Autronexa.
Schneider Electric
iC60N 2P C20
Genuine surplus Schneider Electric iC60N 2P C20 miniature circuit breaker — 20A, C-curve, 6 kA, verified and ready…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
