Schneider Electric I/O & Function Modules
Schneider Electric 140AII33000C
Input Module
Genuine surplus Schneider Electric 140AII33000C input module — verified, tested against OEM specs, and ready to ship from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Measurement Current | 0.5 mA |
|---|---|
| Source Resistance | <200 Ohm |
| Input Impedance | > 10 mOhm |
| Linearity | 0.00% |
| Resolution | 0.76 µV |
| Power Dissipation | 2W |
| Protection Type | Internal Fuse |
| Bus Current Requirement | 400 mA |
| ESD Resistance | 4 kV |
| Max. Operating Altitude | 1000m above sea level |
Description
The Schneider Electric 140AII33000C is a Modicon Quantum input module built for precise measurement in process control and monitoring systems. Maintenance and procurement teams choose genuine surplus or refurbished units of this module to avoid OEM lead times and list-price premiums while keeping signal fidelity intact.
What This Input Module Does in a Quantum Rack
The 140AII33000C registers a measurement current of 0.5 mA and delivers a resolution of 0.76 µV, so it captures small signal changes that coarser modules would miss. Its input impedance exceeds 10 mOhm and source resistance stays below 200 Ohm, which keeps loading effects low and protects measurement accuracy. Linearity is specified at 0.00%, meaning the output tracks the input without correction across the working range. For a plant running analog loops, that combination reduces the need for re-calibration and signal-conditioning hardware — both recurring cost lines. The module draws 400 mA from the bus and dissipates 2W, so it fits existing rack power budgets without forcing a supply upgrade.

Surplus Advantage: Cost and Lead Time on a Proven Module
Buying this module as genuine surplus or refurbished changes the economics of a spare-parts program. OEM list pricing on Quantum-series modules reflects new-production cost, while a verified surplus unit delivers the same measurement performance at a lower capital outlay. Autronexa sources units and tests them against OEM datasheet specifications, then functionally verifies them before they enter stock — genuine parts, verified. For maintenance teams holding critical spares, that means a replacement can be on the shelf before a failure occurs rather than ordered after one. The internal fuse provides overload defense, and the 4 kV electrostatic discharge resistance supports use in electrically noisy cabinets, so a tested unit returns to service with its protection intact. Please verify current lifecycle status and availability with Autronexa before ordering.

Sourcing Checklist Before You Buy
Confirm the exact part number and revision match your existing rack configuration — Quantum installations sometimes carry mixed module revisions, and matching them avoids commissioning surprises. Ask for the condition grade: surplus units pulled from service and refurbished units tested against OEM specifications are different products with different pricing. Check that the internal fuse is intact and that the unit has been functionally verified, not just visually inspected. Confirm the 1000 m maximum operating altitude suits your installation site. Autronexa provides sourcing help across Allen-Bradley, Bently Nevada, Siemens, Schneider and more, so a single request can cover the whole rack. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric 140AII33000C, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished modules, not grey-market copies.
What condition will the 140AII33000C arrive in?
Units ship in refurbished condition as the site default: tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask us for the specific condition grade on the unit reserved for you.
How fast can you ship the 140AII33000C?
Contact Autronexa for current lead time. Stock levels on surplus Quantum modules change quickly, so we confirm availability and ship date against your order before committing.
Does the 140AII33000C fit an existing Modicon Quantum rack?
It is a Modicon Quantum input module with a 400 mA bus current requirement and 2W power dissipation. Confirm your rack power budget and module revision match before ordering.
Is the 140AII33000C still supported by Schneider Electric?
Contact Autronexa to verify OEM support status. We can advise on current lifecycle position and alternative sourcing routes for the Quantum series.
Related & compatible parts
Schneider Electric
140DAO84220
Genuine surplus Schneider 140DAO84220 16-point AC Triac output module — verified condition, practical sourcing for discontinued Modicon Quantum…
Schneider Electric
ATV930C13N4
Genuine surplus Schneider ATV930C13N4 drive — 132 kW ND/110 kW HD, dual-rated, verified condition, faster than OEM lead…
Schneider Electric
TM2DDI16DT
Genuine surplus Schneider Electric TM2DDI16DT: 16 discrete 24 V DC inputs for Modicon M238, verified and ready to…
Schneider Electric
TM3DI8
Genuine surplus Schneider Electric TM3DI8 digital input module — 8 channels, 24 Vdc, verified condition and practical lead…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…