Schneider Electric I/O & Function Modules

Schneider Electric 140AII33000C

Input Module

Manufacturer: Schneider Electric Part Number: 140AII33000C

Genuine surplus Schneider Electric 140AII33000C input module — verified, tested against OEM specs, and ready to ship from Autronexa.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Measurement Current 0.5 mA
Source Resistance <200 Ohm
Input Impedance > 10 mOhm
Linearity 0.00%
Resolution 0.76 µV
Power Dissipation 2W
Protection Type Internal Fuse
Bus Current Requirement 400 mA
ESD Resistance 4 kV
Max. Operating Altitude 1000m above sea level

Description

The Schneider Electric 140AII33000C is a Modicon Quantum input module built for precise measurement in process control and monitoring systems. Maintenance and procurement teams choose genuine surplus or refurbished units of this module to avoid OEM lead times and list-price premiums while keeping signal fidelity intact.

What This Input Module Does in a Quantum Rack

The 140AII33000C registers a measurement current of 0.5 mA and delivers a resolution of 0.76 µV, so it captures small signal changes that coarser modules would miss. Its input impedance exceeds 10 mOhm and source resistance stays below 200 Ohm, which keeps loading effects low and protects measurement accuracy. Linearity is specified at 0.00%, meaning the output tracks the input without correction across the working range. For a plant running analog loops, that combination reduces the need for re-calibration and signal-conditioning hardware — both recurring cost lines. The module draws 400 mA from the bus and dissipates 2W, so it fits existing rack power budgets without forcing a supply upgrade.

Figure 1: Front view of the Schneider Electric 140AII33000C Input Module showing its physical design and enclosure.

Surplus Advantage: Cost and Lead Time on a Proven Module

Buying this module as genuine surplus or refurbished changes the economics of a spare-parts program. OEM list pricing on Quantum-series modules reflects new-production cost, while a verified surplus unit delivers the same measurement performance at a lower capital outlay. Autronexa sources units and tests them against OEM datasheet specifications, then functionally verifies them before they enter stock — genuine parts, verified. For maintenance teams holding critical spares, that means a replacement can be on the shelf before a failure occurs rather than ordered after one. The internal fuse provides overload defense, and the 4 kV electrostatic discharge resistance supports use in electrically noisy cabinets, so a tested unit returns to service with its protection intact. Please verify current lifecycle status and availability with Autronexa before ordering.

Figure 2: Technical layout and connection details for the Schneider Electric 140AII33000C Input Module.

Sourcing Checklist Before You Buy

Confirm the exact part number and revision match your existing rack configuration — Quantum installations sometimes carry mixed module revisions, and matching them avoids commissioning surprises. Ask for the condition grade: surplus units pulled from service and refurbished units tested against OEM specifications are different products with different pricing. Check that the internal fuse is intact and that the unit has been functionally verified, not just visually inspected. Confirm the 1000 m maximum operating altitude suits your installation site. Autronexa provides sourcing help across Allen-Bradley, Bently Nevada, Siemens, Schneider and more, so a single request can cover the whole rack. Contact Autronexa with your part number for verified condition and current availability.

Frequently asked questions

Is this a genuine Schneider Electric 140AII33000C, or a clone?

Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished modules, not grey-market copies.

What condition will the 140AII33000C arrive in?

Units ship in refurbished condition as the site default: tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask us for the specific condition grade on the unit reserved for you.

How fast can you ship the 140AII33000C?

Contact Autronexa for current lead time. Stock levels on surplus Quantum modules change quickly, so we confirm availability and ship date against your order before committing.

Does the 140AII33000C fit an existing Modicon Quantum rack?

It is a Modicon Quantum input module with a 400 mA bus current requirement and 2W power dissipation. Confirm your rack power budget and module revision match before ordering.

Is the 140AII33000C still supported by Schneider Electric?

Contact Autronexa to verify OEM support status. We can advise on current lifecycle position and alternative sourcing routes for the Quantum series.

Related & compatible parts

Schneider Electric

140DAO84220

Genuine surplus Schneider 140DAO84220 16-point AC Triac output module — verified condition, practical sourcing for discontinued Modicon Quantum…

In Stock

Schneider Electric

ATV930C13N4

Genuine surplus Schneider ATV930C13N4 drive — 132 kW ND/110 kW HD, dual-rated, verified condition, faster than OEM lead…

In Stock

Schneider Electric

TM2DDI16DT

Genuine surplus Schneider Electric TM2DDI16DT: 16 discrete 24 V DC inputs for Modicon M238, verified and ready to…

In Stock

Schneider Electric

TM3DI8

Genuine surplus Schneider Electric TM3DI8 digital input module — 8 channels, 24 Vdc, verified condition and practical lead…

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: 140AII33000C

We reply within one business day.

140AII33000C Quote reply within 1 business day